14
Installation Guideline
1) Attach the drain hose to the underside of the refrigerant
pipes with adhesive vinyl tape.
2) Be sure to connect the drain hose to the drain port in place
of a drain plug.
3) Shape the refrigerant pipe along the pipe path marking on
the mounting plate.
4) Pass drain hose and refrigerant pipes through the wall
hole, then set the indoor unit on mounting plate hooks,
using the markings at the top of indoor unit as a guide.
5) Pull in the inter-unit wiring.
6) Connect the inter-unit piping.
7) Wrap the refrigerant pipes and drain hose together with
insulation tape as right figure.
8) Take extra care while going through activities so that the
interconnecting wires do not damaged by indoor unit, press
the bottom edge of indoor unit with both hands until it is firmly
caught by the mounting plate hooks. Secure indoor unit to the
mounting plate with the screws (M4 × 12L).
1) Insert the drain hose to this depth so it won’t be pulled out of
the drain pipe.
Left-side piping
Remove pipe port cover
here for left-bottom piping.
Left-back piping
Left-bottom piping
Remove pipe port cover
here for left-side piping.
No gap
Do not apply lubricating oil (refrigerant
machine oil) when inserting.
Application of causes deterioration
and drain leakage of the plug.
• How to set drain plug
Insert a hexagon wrench (4mm)
¢
How to attach the indoor unit
Hook the claws of the bottom frame to
the mounting plate.
¢
How to remove the indoor unit.
Push up the marked area (at the lower
part of the front grille) to release the
claws.
Claw
Mounting plate
Bottom frame
Front grille
Mark (rear side)
Caulk this hole
with putty or
caulking material
Bind with plastic tape.
Drain hose
Wrap insulating tape around the bent portion of refrigerant pipe.
Overlap at least half the width of the tape with each turn.
Mounting plate
Mounting plate
M4 × 12L (2 point)
Refrigerant pipes
Drain hose
Bottom frame
Insert drain hose
to this depth so
it won’t be pulled
out of drain pipe.
Inner wall
Drain hose
Vinyl chloride drain pipe
(VP-30)
Outer wall
50 mm or more
Wall embedded piping.
Follow the instructions given under
Left-side, left-back, or left-bottom piping
The indoor unit must be installed in such a way so as to prevent short circuit of the cool discharged air with the
hot return air. Please follow the installation clearance shown in the figure. Do not place the indoor unit where there
could be direct sunlight shining on it. Also, this location must be suitable for piping and drainage, and be away
from doors or windows.
Air flow
(Indoor)
min
. 55
(Space
for
per
for
mance)
Required space
Return Air
All dimensions are in mm
min. 50
(Space for
maintenance)
min. 50
(Space for
maintenance)
Содержание FTV-A Series
Страница 1: ...TM FTV 1020 F Split Unit Air Conditioner Wall Mounted FTV A P PS Series Cooling Only 50Hz...
Страница 2: ......
Страница 30: ...28 Dimensions Model FTV85PS Note Dimension in mm FOR ILLUSTRATIVE PURPOSES ONLY...
Страница 33: ...31 Dimensions Model RC85A Note Dimension in mm FOR ILLUSTRATIVE PURPOSES ONLY...
Страница 35: ...33 Wiring Diagram Model RV35A Model RV50 60A R08024149386 3P548018 1...
Страница 37: ...35 Wiring Diagram Model FTV50 60P Outdoor Unit Model RV50 60C R08024149860A R08024145839...
Страница 44: ...42 Piping Diagram Model RV50 60C Note Dimension in mm Model RC85A Note Dimension in mm 3D121531...
Страница 56: ...54 Capacity Tables FTV28P RV28F FTV35P RV35F...
Страница 68: ...66 Sound Level FTV85PS...