Refrigeramt Diagram
75
6.10.2 Trial Operation
1. Measure the supply voltage and make sure that it falls within the specified range.
2. Trial operation should be carried out in either cooling or heating operation.
3. Carry out the trial operation in accordance with the operation manual to ensure that all functions and parts,
such as louver movement, are working properly.
• The air conditioner requires a small amount of power in standby mode. If the system is not to be
used for some time after installation, shut off the circuit breaker to eliminate unnecessary power
consumption.
• If the circuit breaker trips to shut off the power to the air conditioner, the system backs up the
operation mode. The system then restarts operation with the previous operation mode when the
circuit breaker is restored. [details refer to section 2.14 Auto Random Restart]
4. In cooling operation, select the lowest programmable temperature; in heating operation, select the highest
programmable temperature.
• Trial operation may be disable in either operation mode depending on the room temperature.
• After trial operation is complete, set the temperature to a normal level.
[26 - 28°C (78.8 – 82.4°F) in cooling, 20 - 24°C (68 – 75.2°F) in heating]
• For protection, the system does not start for 3 minutes after it is turned off.
6.10.3 Field Settings
6.10.3.1 Temperature Display Switch
•Y ou can select Fahrenheit or Celsius for temperature display
• Press the TEMP ▲and ▼ buttons simultaneously for 5 seconds to change the unit temperature
display
• Default setting: Fahrenheit
6.10.4 Silicon Grease on Power Transistor / Diode Bridge
Apply the specified silicon grease to the heat radiation part of a power transistor /diode bridge when you
replace an outdoor unit PCB. The silicon grease encourages the heat radiation of a power transistor / diode
bridge.
<Details>
1. Wipe off the old silicon grease completely.
2. Apply the silicon grease evenly. See the illustration below for examples of application.
3. Tighten the screws of the power transistor / diode bridge.
4. Make sure that the heat radiation parts are firmly contacted to the radiation fin.
Note: smoke emission may be caused by bad heat radiation when the silicon grease is not appropriately applied.