![Daikin FTK25JV1NB9 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/daikin/ftk25jv1nb9/ftk25jv1nb9_service-manual_2459333041.webp)
General Functionality
Si04-115
32
Main Function
1.11
Good Sleep Cooling Control
Outline
The function to create deep sleeping and to offer good sleep by altering the set temperatures in
certain intervals to give temperature variation to a living space based on “1/f temperature
fluctuation” principle, in case of going to bed while air conditioner keeps operating in cooling
mode.
Processing
Notes:
1. Each timer’s counting/stop is not related to a thermostat ON/OFF.
2. When the sleeping control works by the OFF timer, the shift from the set temperature should
be just 1°C with this control function.
(The temperature shift of the normal OFF-timer will not be carried out. However, the passed
time should be remembered since the OFF-timer was set.)
3. While operation with the good sleep cooling control and off-timer setting, if the signal of the
good sleep cooling OFF signal comes, the level of the set temperature shift should be set
corresponding to the same with an existing value in accordance with the passed time since
the OFF-timer was set.
4. When the good sleep cooling control is on while a normal operation with a OFF-timer is
going on, once returning to the original criterion which doesn’t shift the timer’s set
temperature, and the shift alteration at every sequence by 1°C is carried out in accordance
with the value above mentioned.
5. Fan speed will change by the alteration of the set temperature by 1°C at the automatic fan
speed operation mode, and it causes an alteration of fan noise. So, the fan tap should be
fixed at L tap position during the good sleep cooling even at the auto fan speed operation.
6. The function of the good sleep cooling is cancelled, when the good sleep cooling operation
is off or operation OFF command is received or also the operation mode changes to the
mode except cooling.
7. The priority order for each function is ; ‘Powerful’, ‘Intelligent eye’, ‘Good sleep’, and ‘Night
set mode’.
one cycle
repeating
20
17
63
41
63
27
20
21
60
63
22
63
20
60
Set temp.+1˚C
the set temperature
before the good sleep
cooling
Entering the good
sleep control (ON)
[Unit: min]
(R1917)
Содержание FTK25JV1NB9
Страница 10: ...Si04 115 List of Function 1 Part 1 List of Function 1 Functions 2 1 1 Indoor Unit and Outdoor Unit 2...
Страница 50: ...Si04 115 System Configuration 41 Part 5 System Configuration 1 Instruction 42 1 1 FTK25 35J FTX25 35J 42...
Страница 69: ...Instruction Si04 115 60 System Configuration...
Страница 134: ...Si04 115 For RK25J RK35J RX25J RX35J Removal Procedure 125 2 Slide the MID upward and release Step Procedure Points...
Страница 136: ...Si04 115 For RK25J RK35J RX25J RX35J Removal Procedure 127 4 Remove the fan motor Step Procedure Points...
Страница 145: ...For RK25J RK35J RX25J RX35J Si04 115 136 Removal Procedure...