The indoor unit must be installed in such a way so as to prevent
short circuit of the cool discharged air with the hot return air.
Please follow the installation clearance shown in the figure. Do
not place the indoor unit where there could be direct sunlight
shining on it. Also, this location must be suitable for piping
and drainage, and be away from doors or windows.
min. 50
(Space for
maintenance)
Air flow
(Indoor)
The refrigerant piping can be routed to the unit in a number of
ways (left or right from the back of the unit), by using the cut-
out holes on the casing of the unit (see figure). Bend the pipes
carefully to the required position in order to align it with the
holes. For the side and bottom, hold the bottom of the piping
and then position it to the required direction (see figure). The
condensation drain hose can be taped to the pipes.
Right-side, right-back or right-bottom piping
min. 50
(Space for
maintenance)
min. 30
(Space for
performance)
Required space
Right-back piping
Bind coolant pipe
and drain hose
together with
insulating tape.
All dimensions are in mm
Right-bottom
piping
Remove pipe port cover
here for right-bottom piping
Right-side
piping
Remove pipe port cover
here for right-side piping
Remove pipe port cover here for
left-bottom piping
Remove pipe port
cover here for
left-side piping
Left-back
piping
Left-side
piping
Left-bottom piping
Left-side, left-back or left-bottom piping
INSTALLATION OF THE INDOOR UNIT