background image

8

Preparation Before Operation

Indoor unit

Setting the air purifying filters

1

Open the front grille.

Hold the grille by the tabs on the two
sides and lift it until it stops with a click.
(about 60°)

2

Pull out the air filters.

Push upwards the
tab at the center of
each air filter, then
pull it down.

3

Set the air purifying filters.

Attach an air purifying filter to each air
filter.
(See page 12 “Care and cleaning”)

4

Set the air filters in their original
positions and close the front grille.

Operation without air filters may result in
troubles as dust will accumulate inside
the indoor unit.

Setting the clock

1

Press 

 .

AM

 is displayed.

 blinks.

2

Press 

TIMER

 to set the clock to the

present time.

Holding down ( 

 ) or ( 

 ) button rapidly

increases or decreases the time display.

3

Press 

 .

 blinks.

(Now the clock is set.)

Turn the breaker ON

Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)

AM

Display

PM

Display

PM

Display

NOTE

Tips for saving energy

Be careful not to cool the room too much.
Keeping the temperature setting at a
moderate level helps save energy.

Recommended temperature setting

For cooling: 26°C – 28°C

Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors
increases the cooling effect.

Clogged air filters cause inefficient
operation and waste energy.  Clean them
once in about every two weeks.

Please note

The air conditioner always consumes 15 – 35
watts of electricity even while it is not operating.

If you are not going to use the air conditioner
for a long period, for example in spring or
autumn, turn the breaker OFF.

Use the air conditioner in the following conditions.

Mode

COOL

DRY

Operating conditions

Outdoor temperature : 19 to 46 °C
Indoor temperature : 18 to 32 °C
Indoor humidity

: 80% max.

Outdoor temperature : 21 to 46 °C
Indoor temperature : 18 to 32 °C
Indoor humidity

: 80% max.

If operation is continued out of this range

A safety device may work
to stop the operation.
(In multi system, it may
work to stop the operation
of the outdoor unit only.)

Condensation may occur
on the indoor unit and drip.

A safety device may work
to stop the operation.

Condensation may occur
on the indoor unit and drip.

Содержание FT50GAVE

Страница 1: ...FT50GAVE FT60GAVE MODELS MODELOS DAIKIN ROOM AIR CONDITIONER AR CONDICIONADO DE SALA DAIKIN Operation Manual ManualdeFuncionamento ENGLISH P1 P16 PORTUGUES P17 P32...

Страница 2: ...e horizontal blade flap 9 Adjusting the vertical blade louvre 9 POWERFUL Operation 10 Timer Operation OFF TIMER operation 11 ON TIMER operation 11 CARE Care and Cleaning Cleaning the air filters 12 Cl...

Страница 3: ...ng any repairs which might accompany addition of refrigerant The refrigerant used in the air conditioner is safe Although leaks should not occur if for some reason any refrigerant happens to leak into...

Страница 4: ...n to mount on the outdoor unit or avoid placing any object on it Falling or tumbling may result in injury Installation WARNING Do not attempt to install the air conditioner by yourself Consult the ser...

Страница 5: ...neighbours from noises For installation choose a place as described below A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration A place from wher...

Страница 6: ...temperature sensor It senses the air temperature around the unit Push this switch once to start operation Push once again to stop it The operation mode refer to the following table This switch is usef...

Страница 7: ...irection It changes the temperature setting Display It displays the current settings In this illustration each section is shown with all its displays ON for the purpose of explanation Some models may...

Страница 8: ...trol holder ATTENTION About batteries When replacing the batteries use batteries of the same type and replace the two old batteries together When the system is not used for a long time take the batter...

Страница 9: ...l not to cool the room too much Keeping the temperature setting at a moderate level helps save energy Recommended temperature setting For cooling 26 C 28 C Cover windows with a blind or a curtain Bloc...

Страница 10: ...of air flow rate setting from to plus are available Display Adjusting the Air Flow Direction ATTENTION Be careful when adjusting the louvre Inside the air outlet a fan is rotating at a high speed ATTE...

Страница 11: ...e used before POWERFUL operation During you use POWERFUL operation the other functions will not go on 1 Press To cancel POWERFUL operation Press Notes on POWERFUL operation In COOL mode To maximize th...

Страница 12: ...k is correct If not set the clock to the present time See page 8 1 Press ON while the air conditioner is not operating AM is displayed blinks Previous time setting appears on display 2 Press TIMER unt...

Страница 13: ...oor cooling may cause odour Item Air purifying filter with frame Air purifying filter without frame Part No KAF918A41 KAF918A42 Push Before cleaning be sure to stop the operation and turn the breaker...

Страница 14: ...he grille with water After washing dry it with cloth then dry it up in the shade 4 Attach the front grille Set the 3 keys of the front grille into the slots and push them in all the way Supporting the...

Страница 15: ...enses into water on the cool surface of outdoor unit piping and drips This happens when the air in the room is cooled into mist by the cold air flow during cooling operation This happens when smells o...

Страница 16: ...he indoor and the outdoor units Is the temperature setting appropriate Are the windows and doors closed Are the air flow rate and the air direction set appropriately Are the air filters clean Is there...

Страница 17: ...l after several seasons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenance contact...

Страница 18: ...3P062628 8K M00B042C 0406 HT...