14
Trouble Shooting
●
These cases are not troubles.
The following cases are not air conditioner troubles but have some reasons. You may just continue
using it.
Case
Operation does not start soon.
●
When ON/OFF button was
pressed soon after
operation was stopped.
●
When the mode was
reselected.
The outdoor unit emits water
or steam.
Mists come out of the indoor
unit.
The indoor unit gives out
odour.
The outdoor fan rotates while
the air conditioner is not in
operation.
The operation stopped
suddenly.
(OPERATION lamp is on)
Explanation
●
This is to protect the air conditioner.
You should wait for about 3 minutes.
■
In COOL or DRY mode
•
Moisture in the air condenses into water on the cool
surface of outdoor unit piping and drips.
■
This happens when the air in the room is cooled into mist
by the cold air flow during cooling operation.
■
This happens when smells of the room, furniture, or
cigarettes are absorbed into the unit and discharged with
the air flow.
(If this happens, we recommend you to have the indoor unit
washed by a technician. Consult the service shop where
you bought the air conditioner.)
■
After operation is stopped:
•
The outdoor fan continues rotating for another 60
seconds for system protection.
■
While the air conditioner is not in operation:
•
When the outdoor temperature is very high, the out
door fan starts rotating for system protection.
■
For system protection, the air conditioner may stop
operating on a sudden large voltage fluctuation.
It automatically resumes operation in about 3 minutes.