Removal of Indoor Heat Exchanger
Si041048
26
Removal Procedure
2. Remove the indoor unit.
1
Remove the indoor unit
from the installation
plate.
3. Remove the indoor heat
exchanger.
1
Unfasten the hook of
the piping fixture at the
back of the unit and pull
out the pipe.
2
Slightly widen the
auxiliary piping.
3
Unfasten the upper
hook (left) with a flat
screwdriver.
Caution
When removing or
reassembling the indoor heat
exchanger, be sure to wear
gloves or wrap the indoor
heat exchanger with cloths.
(You may be injured by the
fins.)
Step
Procedure
Points
(R4400)
(R4401)
Piping fixture
(R17157)
(R4403)
Upper hook
(left)
Lower hook
(left)