Si041048
Removal of PCBs
Removal Procedure
13
6. Removal of PCBs
Procedure
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the shield plate.
Preparation
Remove the electrical box
according to the “Removal
of Electrical Box.”
1
2
3
The figure shows the
appearance of the
electrical box.
Open the shield plate.
Push the upper center
of the shield plate and
unfasten the 2 hooks.
Remove the shield
plate.
2. Release the indoor heat
exchanger thermistor.
1
Release the indoor heat
exchanger thermistor
and the earth wire from
the hooks.
Signal receiver
PCB
Signal receiver unit
(R4350)
Shield plate
Hook
(R13208)
Hook
Hook
(R4352)
Earth wire
Clamp
(R4353)
Indoor heat
exchanger
thermistor