AIR CONDITIONER UNIT OPERATION
Frost Prevention
• When the air filter is dirty, the evaporating temperature will
decrease and eventually cause frosting.
• The LED light will blink to indicate that the filter is dirty. If
the evaporating temperature reaches -1°C/33.8°F, the unit
will trip and defrost.
Fan Speed And Rated Cooling Capacity
• The rated cooling capacity is provided at the maximum fan
speed.
• The cooling capacity is lower when the unit is operating at
MEDIUM and LOW fan speed.
Dry Mode
• When the air humidity is high, the unit can operate in dry
mode. Press <MODE> button and choose <DRY>.
• If the room temperature is 2°C/3.6°F higher than the set
temperature, the air conditioner will operate under cooling
mode until it reaches within the 2°C/3.6°F range of
difference compared to the set temperature before it converts
to dry mode.
• If the room temperature is within the 2°C/3.6°F range of
difference compared to the set temperature, it will
directly operate under dry mode.
• The unit will operate at LOW speed under dry mode.
Horizontal Air Flow Control
• For more effective air circulation, you can manually adjust
the air discharge grille to the left or right.
• During cool mode operation and dry mode operation, do
not direct the air discharge louver downwards for too long.
If operating continues in this way, condensation may occur
on the louver, thus resulting in drippings.
Cooling
Dry
Horizontal
25°C/77°F
!
CAUTION
1. The electrostatic air purifying and deodorizing filter should be replaced once every 6 months or when the
filter changes color to brownish, whichever is sooner.
2. Used dusty filters should be disposed and shouldn't be reused, even if it has been cleaned and washed.
3. The filter is a consumable part which you can purchase from your air conditioner dealer.
4. Use the new filter immediately once it has been taken out from its sealed packing. Do not unpack the new filter too early before
it is actually used as this may decrease its deodorizing effect.
STANDARD OPERATING CONDITIONS
Cooling Unit
Ts: Dry bulb temperature. Th: Wet bulb temperature.
Temperature
Ts °C/°F
Th °C/°F
Minimum indoor
19.4 / 66.9
13.9 / 57.0
temperature
Maximum indoor
26.7 / 80.1
19.4 / 66.9
temperature
Minimum outdoor
19.4 / 66.9
13.9 / 57.0
temperature
Maximum outdoor
46 / 114.8
24 / 75.2
temperature