manualshive.com logo in svg
background image

FT18JV1B

FTY18JV1B

FT25JV1B

FTY22JV1B

FT35JV1B

FTY35JV1B

Operation Manual

MODELS

DAIKIN ROOM AIR CONDITIONER

ENGLISH

DEUTSCH

FRANÇAIS

NEDERLANDS

ESPAÑOL

ITALIANO

EËËHNIKA

PORTUGUES

DANSK

NORSK

SUOMI

Содержание FT18JV1B

Страница 1: ...FT18JV1B FTY18JV1B FT25JV1B FTY22JV1B FT35JV1B FTY35JV1B Operation Manual MODELS DAIKIN ROOM AIR CONDITIONER ENGLISH DEUTSCH FRAN AIS NEDERLANDS ESPA OL ITALIANO E HNIKA PORTUGUES DANSK NORSK SUOMI...

Страница 2: ...e flap 10 Adjusting the vertical blade louvre 10 POWERFUL Operation 10 Timer Operation OFF TIMER operation 11 ON TIMER operation 11 CARE Care and Cleaning Cleaning the air filters 12 Cleaning the indo...

Страница 3: ...ere the unit was purchased Check with a qualified repairman before attempting any repairs which might accompany addition of refrigerant The refrigerant used in the air conditioner is safe Although lea...

Страница 4: ...g may result in injury Installation WARNING Do not attempt to install the air conditioner by yourself Consult the service shop or a qualified technician Incorrect work will result in water leakage ele...

Страница 5: ...neighbours from noises For installation choose a place as described below A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration A place from wher...

Страница 6: ...nals from the remote controller When the unit receives a signal you will hear a short beep Before opening the front grille be sure to stop the operation and turn the breaker OFF If the power is on the...

Страница 7: ...ation each section is shown with all its displays ON for the purpose of explanation Some models may not show all its indications ON TIMER button See page 11 TIMER Setting button It changes the time se...

Страница 8: ...the remote controller aim the transmitter at the indoor unit If there is anything to block signals between the unit and the remote controller such as a curtain the unit will not operate Do not drop th...

Страница 9: ...while it is not operating If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker OFF Use the air conditioner in the following conditions Mo...

Страница 10: ...tion Since this air conditioner heats the room by taking heat from outdoor air to indoors the heating capacity becomes smaller in lower outdoor temperatures If the heating effect is insufficient it is...

Страница 11: ...ting Display Press ON No display Adjusting the Air Flow Direction You can adjust the air flow direction to increase your comfort Adjusting the horizontal blade flap To stop the flap at an angle you li...

Страница 12: ...cancel the timer Then the TIMER lamp goes off Check that the clock is correct If not set the clock to the present time See page 8 1 is displayed blinks Previous time setting appears on display 2 Press...

Страница 13: ...s Take off the air purifying filters Wipe them with dry soft cloth For cleaning do not use water hotter than 40 C benzine gasoline thinner nor other volatile oils polishing compound scrubbing brushes...

Страница 14: ...and push them in all the way Supporting the front grille with one hand fit the lock by sliding up the knob with the other hand Close the front grille slowly in this state Push the grille at the 3 poin...

Страница 15: ...e system is taking away the frost on the outdoor unit You should wait for about 3 to 10 minutes In HEAT mode The frost on the outdoor unit melts into water or steam when the air conditioner is in defr...

Страница 16: ...Is the temperature setting appropriate Are the windows and doors closed Are the air flow rate and the air direction set appropriately Are the air filters clean Is there anything to block the air inle...

Страница 17: ...ails to work properly There is a burning smell Water leaks from the indoor unit Turn the breaker OFF and call the service shop After a power failure The air conditioner automatically resumes operation...

Страница 18: ...TOR OR STOPPED BY HIGH PRESSURE CONTROL FAN MOTOR FAULT FAULTY HEAT EXCHANGER SENSOR FAULTY SUCTION AIR TEMPERATURE SENSOR CODE 00 U0 U2 U4 U5 A5 A6 C4 OR C5 C9 SYSTEM INDOOR UNIT MEANING INTERNAL THE...

Страница 19: ......

Страница 20: ...3P062628 1L M00B035B 0507 HT...

Отзывы: