WINDOW AC UNIT INSTALLATION GUIDELINES 

INSTALLING THE UNIT 

For testing purpose and enhanced performance 

use the Installation guidelines given below 

•  The unit should be inclined 15-20mm (0.6-0.8

Inches) towards the back for optimum perfor­

mance

•  For optimum performance  drain should be

plugged.

INSTALLATION PROCEDURES 

1. Remove the cabinet screws from rear side.

2. Slide the chassis out from the cabinet.

3. Place cabinet into the installation hole.

Tilt down 

for better 

drainage 

(max. 

10mm). 

Secure it with wood screws or 

nails 

4. Slide the chassis into the cabinet. 

5. Lock the chassis to the cabinet with screws. 

From back 

side (2 places). 

6. Depending upon the location of the AC

outlet, route the AC cord to either left or 

right side while installing the front grill. 

This figure shows the AC cord routed to the right side. 

7.  Attach the front grill to the cabinet and 

fasten it with screws. 

Screw 

at this 

Содержание FRWKL50UV163

Страница 1: ...ay result in a failure electric shocks or fire hazards Be sure to earth the unit Do not earth the unit to a e utility pipe lightning conductor or telephone earth lead Imperfect earthing may result in...

Страница 2: ...t is earthed through the power supply cord Please contact the manufacturer or its service dealer or a similarly qualified person if you want to replace it 3 This unit is earthed through the power cord...

Страница 3: ...OFFTIMER button Press this button and adjust the OFF TIME The time can be set between 1 to 9 hours TIMER CANCEL button Cancels the timer setting NOTE Notes on remote controller Never expose the remot...

Страница 4: ...temperature setting at a moderate level helps save energy Cover windows with a blind or a curtain Blocking sunlight and air from outside increases the cooling effect Clogged air filters cause ineffici...

Страница 5: ...Ds and seven segment display Various modes of operation Wireless IR remote based controlling operations Remote having the all keys fluorescent type Auto Restart DISPLAY There are various LEDs on the R...

Страница 6: ...swing motor FAN SPEED This key Changes the Fan speed to High Medium Low or Auto ECONO To activate deactivate the Econo operation Note Vertical swing feature is not applicable for window series of mode...

Страница 7: ...ferential of Room Temp Set Temperature Preset temperature from18 Cto 32 C and fan speed low medi um high auto can be changed by the user Fan Speed Can be Selected Auto High Medium or Low Compressor wi...

Страница 8: ...Note Whenever AC is switched OFF in dry mode and is switched ON from remote air conditioner will start in Cool mode and then DRY mode selection can be done using the MODE button NOTE Note on COOL oper...

Страница 9: ...ker from tripping when the unit operates alongside other appliances on the same circuit To start ECONO operation Press during operation 11 11 is displayed on the LCD To Cancel ECONO operation Press S...

Страница 10: ...CHIL together for about 5 seconds we will be displayed on the remote LCD If a button is pressed while CHILD LOCK is on we blinks To cancle the Child Lock Press t ECONO and together for about 5 seconds...

Страница 11: ...temperature TIMER Operation Timer functions are useful for automatically switching the air conditioner ON or OFF in the morning or at night You can also use the ON TIMER and GOOD SLEEP OFF TIMER toget...

Страница 12: ...After replacing the batteries in the remote controller GOOD SLEEP Operation 12 To use GOOD SLEEP OFF TIMER operation GOODSLEEP Press o during COOL operation C blinks for a few seconds The temperature...

Страница 13: ...MER operation The set temperature increases by 0 5 C in 30minutes until the total increase reaches the specified shift value There is no function for heating the room EXAMPLE Temperature shift value a...

Страница 14: ...essor is turned on A splashing sound indicating condensed water splashing on the condenser coil If you hear other noises please consult Daikin Authorized Service Centre Case 2 If the unit does not ope...

Страница 15: ...after sudden large voltage fluctuations It automatically resumes operation in about 3 minutes Voltage Range Protection 145V 275V Case 6 The indoor unit gives out odour fJ The room odour absorbed in t...

Страница 16: ...r unit Is a window or door open Is the air conditioner in ECONO operation or GOOD SLEEP OFF TIMER operation Operation stops Are the air filters dirty suddenly Clean the air filters Is there anything b...

Страница 17: ...aker and call your service centre The air conditioner automatically resumes operation in about 3 minutes You should just wait for a while If there is a risk lightning could strike in the neighbourhood...

Страница 18: ...DISCHARGE PIPE CONTROL F6 HIGH PRESSURE CONTROL IN COOLING OUTDOOR HO SENSOR FAULT UNIT H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR H9 FAULTY SUCTION AIR TEMPERATURE SENSOR J3 FAULTY DIS...

Страница 19: ......

Страница 20: ......

Страница 21: ...ic shocks or fire Install the air conditioner on a foundation strong enough to withstand the weight of the unit A foundation of insufficient strength may result in the equipment falling and causing in...

Страница 22: ...from rear side 2 Slide the chassis out from the cabinet 3 Place cabinet into the installation hole Tilt down for better drainage max 10mm Secure it with wood screws or nails 4 Slide the chassis into t...

Страница 23: ...lines 1 Product warranty 1 INSTALLATION OF FRONT GRILL 1 IDU PCB harness needs to be connect with display PCB W llllii m llil 3 Then close the left and right side locks of front grill with the cabinet...

Страница 24: ...er plug from the body base plate 4 Install the drain pan at the corner of the cabinet 5 Connect the drain hose to the outlet on the bottom of the drain pan 6 Slide the chassis into its original place...

Страница 25: ...tion that can support the weight of the air conditioner and one that will not cause increased operating noise and vibration Ensure that airflow and noise from the rear side of the unit outdoor when in...

Страница 26: ...Gently wash with water and a sponge The filter can be easily cleaned using a vaccum cleaner Vaccum the front of the filter and then wash the rear with water If it is badly soiled wash with a mild hous...

Страница 27: ...n a fine day to dry out the inside 1 Press MoDE and select FAN operation 2 Press and start the operation 2 After operation stops turn off the circuit breaker for the room air conditioner 3 Clean the a...

Страница 28: ...TEMPI 2 Press lrEMPI and MODE J at the same time 3 Press select R press MODE J The good sleep lamp on front panel display will blink for about 1 minute 4 Press the indoor unit ON OFF switch while the...

Страница 29: ...142 X 178 MM Meaning of E waste under E Waste Management Rules 2022 E waste Rules Waste electrical and electronic equipment whole or in part of reject from their manufacturing and repair process which...