manualshive.com logo in svg
background image

Español

English

Portugues

Turkish

FLX25AVMA FLK25AVMA

FLX35AVMA FLK35AVMA

FLX50AVMA FLK50AVMA

FLX60AVMA FLK60AVMA

MODELS

DAIKIN ROOM AIR CONDITIONER

Operation Manual

O  N

OFF

00_CV_3P077961-5K.fm  Page 1  Saturday, July 16, 2005  8:59 PM

Содержание FLX25AVMA

Страница 1: ...Portugues Turkish FLX25AVMA FLK25AVMA FLX35AVMA FLK35AVMA FLX50AVMA FLK50AVMA FLX60AVMA FLK60AVMA MODELS DAIKIN ROOM AIR CONDITIONER Operation Manual O N OFF 00_CV_3P077961 5K fm Page 1 Saturday July...

Страница 2: ...TO DRY COOL HEAT FAN Operation 10 Adjusting the Air Flow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT SILENT Operation 15 HOME LEAVE Operation 16 TIMER Operation 18 Note for Multi System 20 CARE Ca...

Страница 3: ...ce staff Do not attempt to install the air conditioner by your self Incorrect work will result in water leakage electric shocks or fire For installation consult the dealer or a qualified technician In...

Страница 4: ...n cause malfunc tions smoke or fire when making contact with electrical parts Do not operate the air conditioner with wet hands Do not wash the indoor unit with excessive water only use a slightly wet...

Страница 5: ...tion is being carried out to the ceiling The methods of operation used are the same when installing to a wall Opening the front grille How to open the front grille page 22 CAUTION Before opening the f...

Страница 6: ...ain to stop it Push the switch using an object with a sharp tip such as a pen This switch is useful when the remote controller is missing 14 Signal receiver It receives signals from the remote control...

Страница 7: ...once to start operation Press once again to stop it 7 MODE selector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 OUTDOOR UNIT SILENT button page 15 9 FAN setting button It sel...

Страница 8: ...not used for a long time take the batteries out We recommend replacing once a year although if the remote controller display begins to fade or if reception deteriorates please replace with new alkali...

Страница 9: ...with the screws supplied with the holder 3 Place the remote control in the remote control holder ATTENTION About remote controller Never expose the remote controller to direct sunlight Dust on the sig...

Страница 10: ...example in spring or autumn turn the breaker OFF Use the air conditioner in the following conditions Operation outside this humidity or temperature range may cause a safety device to disable the syste...

Страница 11: ...COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights up To stop operation 3 Press ON OFF button again Then OPERATION lamp goes off To change the temperature setting 4 Press TEMPERATURE adjus...

Страница 12: ...operation it takes some time before the room gets warmer In heating operation frost may occur on the outdoor unit and lower the heating capacity In that case the system switches into defrosting operat...

Страница 13: ...NG button The display will light up and the flaps will begin to swing 2 When the flaps have reached the desired position press SWING button once more The display will go blank The flaps will stop movi...

Страница 14: ...angle in COOL or DRY mode to obtain the best performance In COOL or DRY mode if the flap is fixed at a downward position the flap automatically moves in about 60 minutes to prevent condensation on it...

Страница 15: ...Press POWERFUL button again NOTE Notes on POWERFUL operation In COOL and HEAT mode To maximize the cooling heating effect the capacity of outdoor unit must be increased and the air flow rate be fixed...

Страница 16: ...ILENT operation is set on all operated indoor units However if using priority room setting see Note for multi system page 20 This function is available in COOL HEAT and AUTO modes This is not availabl...

Страница 17: ...E LEAVE operation Record your preferred temperature and air flow rate 1 Press HOME LEAVE button Make sure is displayed in the remote control display 2 Adjust the set temperature with or as you like 3...

Страница 18: ...ush the HOME LEAVE Operation button again and the air conditioner will adjust capacity to the set tem perature for normal operation Set the unit to HOME LEAVE Oper ation before leaving the living room...

Страница 19: ...The TIMER lamp lights up To cancel the OFF TIMER operation 4 Press CANCEL button The TIMER lamp goes off Notes When TIMER is set the present time is not displayed Once you set ON OFF TIMER the time s...

Страница 20: ...The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for combining the two timers is shown below ATTEN...

Страница 21: ...flash 2 With the Priority Room Setting active See Priority Room Setting below NIGHT QUIET Mode Available only for cooling operation NIGHT QUIET Mode requires initial programming during installation Pl...

Страница 22: ...es in Room B C and D 2 Priority when POWERFUL operation is used Example Room A is the Priority Room in the examples The indoor units in Rooms A B C and D are all operating If the unit in Room A enters...

Страница 23: ...bles as dust will accumulate inside the indoor unit CAUTION Units Don t touch the metal parts of the indoor unit If you touch those parts this may cause an injury When opening and closing the front gr...

Страница 24: ...recommended to clean the air filters every two weeks Air Purifying Filter green Replace approximately once every 3 months 1 Detach the filter element and attach a new one Insert with the green side up...

Страница 25: ...and consult the ser vice shop if this is the case Operation with dirty filters 1 cannot deodorize the air 2 cannot clean the air 3 results in poor heating or cooling 4 may cause odour The air purifyin...

Страница 26: ...ion In COOL or DRY mode Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mists come out of the indoor unit This happens when the air in the room is cooled...

Страница 27: ...air filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with the remote controller If the lamp still blinks call the service shop w...

Страница 28: ...ce by a specialist aside from regular cleaning by the user For specialist maintenance contact the service shop where you bought the air conditioner The maintenance cost must be born by the user Call t...

Страница 29: ...28 MEMO 01_EN_3P077961 5K fm Page 28 Wednesday July 20 2005 4 47 PM...

Страница 30: ...0507 HT 3P077961 5K M01B040B 00_CV_3P077961 5K fm Page 2 Saturday July 16 2005 8 59 PM...

Отзывы: