background image

FDYP + FBQ + FCQ + FCQH + FDQ
Split system air conditioners
3P468514-7 – 12.2016

Operation manual

1

C

ONTENTS

Page

What to do before operation .............................................................. 1

Important information regarding the refrigerant used ........................ 1

Safety considerations ........................................................................ 1

Names and functions of parts............................................................ 2

Operation range................................................................................. 2

Operation procedure.......................................................................... 3

Optimum operation ............................................................................ 3

Maintenance ...................................................................................... 3

Not a malfunction of the air conditioner ............................................. 5

Troubleshooting ................................................................................. 6

Disposal requirements....................................................................... 6

The English text is the original instruction. Other languages are
translations of the original instructions.

W

HAT

 

TO

 

DO

 

BEFORE

 

OPERATION

 

(See figure 2)

Ask your dealer for installation and re-installation of the air
conditioner.

Incomplete installation performed by yourself may result in water
leakage, electric shock and fire.

Be sure only to use accessories made by Daikin which are
specifically designed for use with the equipment and have them
installed by a professional.

This operation manual is for the following systems with standard
control. Before initiating operation, contact your dealer for the
operation manual that corresponds to your system.

If your installation has a customised control system, ask your dealer
for the operation that corresponds to your system.

Heat pump type
This system provides cooling, heating, automatic, and fan
operation modes.

Straight cooling type
This system provides cooling, and fan operation modes.

I

MPORTANT

 

INFORMATION

 

REGARDING

 

THE

 

REFRIGERANT

 

USED

This product contains fluorinated greenhouse gases.

Refrigerant type:

R407C

GWP

(1)

 value:

1773.85

Refrigerant type:

R410A

GWP

(1)

 value:

2087.5

(1)

 GWP = global warming potential

Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact your local
dealer for more information.

S

AFETY

 

CONSIDERATIONS

To gain full advantage of the air conditioner's functions and to avoid
malfunction due to mishandling, we recommend that you read this
instruction manual carefully before use.

The precautions described herein are classified as WARNING and
CAUTION. They both contain important information regarding safety.
Be sure to observe all precautions without fail.

After reading, keep this manual in a convenient place so that you can
refer to it whenever necessary. If the equipment is transferred to a
new user, be sure also to hand over the manual.

Warning

Be aware that prolonged, direct exposure to cool or warm air
from the air conditioner, or to air that is too cool or too warm can
be harmful to your physical condition and health.

When the air conditioner is malfunctioning (giving off a burning
odour, etc.) turn off power to the unit and contact your local
dealer. Continued operation under such circumstances may
result in a failure, electric shocks or fire hazards.

Do not attempt to install or repair the air conditioner yourself.
Improper workmanship may result in water leakage, electric
shocks or fire hazards. Please contact your local dealer or
qualified personnel for installation and maintenance work.

Do not place objects, including rods, your fingers, etc., in the air
inlet or outlet. Injury may result due to contact with the air
conditioner's highspeed fan blades.

Consult your local dealer regarding what to do in case of
refrigerant leakage. When the air conditioner is to be installed in
a small room, it is necessary to take proper measures so that
the amount of any leaked refrigerant does not exceed the
concentration limit in the event of a leakage. Otherwise, this may
lead to an accident due to oxygen depletion.

Contact professional personnel about attachment of accessories
and be sure to use only accessories specified by the
manufacturer. If a defect results from your own workmanship, it
may result in water leaks, electric shock or fire.

Consult your local dealer regarding relocation and reinstallation
of the air conditioner. Improper installation work may result in
leakage, electric shocks or fire hazards.

Beware of fire in case of refrigerant leakage.

FDYP125~250B8V1

FBQ35~140C8VEB

FDQ125C5VEB

FCQ35~140C8VEB

250B8V3B

FCQH71~140D8VEB

Split system air conditioners

Operation manual

THANK YOU FOR PURCHASING THIS DAIKIN AIR
CONDITIONER. CAREFULLY READ THIS OPERATION
MANUAL BEFORE USING THE AIR CONDITIONER. IT
WILL TELL YOU HOW TO USE THE UNIT PROPERLY
AND HELP YOU IF ANY TROUBLE OCCURS. AFTER
READING THE MANUAL, FILE IT AWAY FOR FUTURE
REFERENCE.

A

Pair system or simultaneous operation system

B

Multi system

1

Unit with remote controller

2

Unit without remote controller (When used as simultaneous 
operation)

WARNING

If the warning is not observed, it may cause serious casualties.

CAUTION

If the caution is not observed, it may cause injury or damage to the 
equipment.

Содержание FDQ125C5VEB

Страница 1: ...FDQ200B8V3B FDQ250B8V3B FBQ35C8VEB FBQ50C8VEB FBQ60C8VEB FBQ71C8VEB FBQ100C8VEB FBQ125C8VEB FBQ140C8VEB FCQ35C8VEB FCQ50C8VEB FCQ60C8VEB FCQ71C8VEB FCQ100C8VEB FCQ125C8VEB FCQ140C8VEB FCQH71D8VEB FCQH...

Страница 2: ...5 50 60 RXS35 50 60 3MKS50 4MKS58 75 90 3MXS52 3MXS52 4MXS68 80 80 80 80 80 80 5 43 10 46 15 46 10 46 15 50 5 46 C DB C WB C DB C WB C DB C WB RZQ200 250 18 35 14 28 80 5 46 C DB C WB C DB C WB C DB C...

Страница 3: ...ent is transferred to a new user be sure also to hand over the manual Warning Be aware that prolonged direct exposure to cool or warm air from the air conditioner or to air that is too cool or too war...

Страница 4: ...dren should be supervised to ensure that they do not play with the appliance Children should be supervised to ensure that they do not play with the unit or its remote controller Accidental operation b...

Страница 5: ...s Refer to Maintenance on page 3 MAINTENANCE Read the operation manual supplied with the remote controller If a function that is not available is selected the message NOT AVAILABLE will appear Operati...

Страница 6: ...ttom suction 6 After turning on the power press FILTER SIGN RESET button The TIME TO CLEAN AIR FILTER display is turned off For FDYP and FDQ200 250B8V3B units See gure 5 1 Remove the screws from the b...

Страница 7: ...ation is different from the remote controller setting For multi split models the micro computer executes the following control depending on the operation mode of other indoor units Before you start to...

Страница 8: ...e air lter is clogged Ask a quali ed service person to clean the air lter The system operates but it does not suf ciently cool or heat If the air inlet or outlet of the indoor or the outdoor unit is b...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...3P468514 7 12 2016 Copyright 2016 Daikin...

Отзывы: