PRECAUTIONS FOR GROUP CONTROL
SYSTEM OR TWO REMOTE CONTROLLERS
CONTROL SYSTEM
This system provides two other control systems
beside individual control (one remote controller
controls one indoor unit) system. Confirm the
following if your unit is one of the following control
system type.
• Group control system
One remote controller controls up to 16 indoor units.
All indoor units are equally set.
• Two remote controllers control system
Two remote controllers control one indoor unit (In
case of group control system, one group of indoor
units).
The unit is individually operated.
NOTE-D
• Contact your local dealer in case of changing the
combination or setting of group control and two
remote controllers control system.
• Please do not change the combination and
settings for the group operation and two remote
controllers control systems by yourself, but be
sure to ask your local dealer.
• Read the operation manual attached to the
remote controller you are using.
If your installation has a customized control system,
ask your local dealer for the operation that
corresponds to your system.
Names and functions of parts
2
7
3
13 10 11
12
9
6
47
1
Air outlet (Field supply)
2
Exhaust duct (Field supply)
3
Drain pipe
4
Refrigerant piping
5
Wiring between indoor and outdoor unit
6
Remote controller (Sold separately)
Drain discharge device (built-in)
7 Discharge indoor moisture removed during
cooling operation.
8
Power line
Ground wire
9
This wire releases electricity from the indoor
unit to the ground in order to prevent electric
shock or fire.
10
Air filter (inside filter chamber) (Sold
separately)
11
Suction filter chamber (Sold separately)
12
Suction duct (Field supply)
Machine nameplate
13
The nameplate is imprinted with the
machine name and specifications.
14
Suction grille (Field supply)
3. OPERATION RANGE
If the temperature or the humidity is beyond the
following conditions, safety devices may work and
the air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING
OUTDOOR
UNIT
RZA
1
2
5
AV
16
RZA
1
40AV
16
HEATING
INDOOR
TEMPERA- HUMIDITY
TURE
D 19 to 35
B
80%
w
or below
B 14 to 24
OUTDOOR
TEMPERA-
TURE
D 21 to 52
B
OUTDOOR
INDOOR
OUTDOOR
UNIT
TEMPERATURE
RZA24AVMK
D
B
10 to 27
RZA30AVMK
DB: Dry bulb temperature (
Q
C)
WB: Wet bulb temperature (
Q
C)
TEMPERATURE
D
-15to 24
B
w
-15to 18
B
RZA
1
2
5
AV
16
RZA
1
40AV
16
Содержание FDMA125AV16
Страница 22: ...4 15 3 30 RZA125AV16 RZA140AV16 RZA125AV16 RZA140AV16...
Страница 50: ...49...
Страница 51: ...50...
Страница 52: ...51...
Страница 53: ...52...
Страница 54: ...53...
Страница 55: ...54 49 48 49 50 50...
Страница 56: ...55...
Страница 58: ...MEMO...
Страница 59: ...MEMO...
Страница 60: ...MEMO 3P727715 6 B...