5.11 E-heater etting
*
E-heater: In
heating mode, E-heater is allowed to be turned on for improvement of effi ciency.
If heating mode is turned on by button operation, auxiliary electric heating function will be automati-
cally turned on.
Press
Function
button in heating mode into auxiliary electric heating function,
E-HEATER
blinking,
and press
Enter/Cancel
button to turn on this function. In this case,
E-HEATER
will be displayed,
which means E-heater is allowed to be turned on.
If auxiliary electric heating function is on, press
Function
button to confirm or press
Enter/Cancel
button to cancel. In this case,
E-HEATER
won’t be displayed, which means E-heater is prohibited to
be turned on.
The setting of this function is shown as Fig.5.11 below:
Auxiliary electric heating
function will be automatically
turn on under heating mode
Press “Function” button
into E-Heater function
Press “Enter/Cancel” button
to turn off E-Heater function
Press “Enter/Cancel” button
to turn on E-Heater function
Press “Function” button
into E-Heater function
Fig.5.11 Auxiliary Electric Heating Function Setting
Note:
E-heater can not be set in cooling, dry and fan mode, E-HEATER mark won’t be displayed. The setting
shown in Fig.5.11.
is
the
S
English