84
Performance Data
Model: FDYM20CXV1 - RY18CXV1 / FDYB20CXV1 - RY18CXV1
Cooling Mode
AFR
(CFM)
EWB
EDB
Outdoor temperature
19°C
25°C
30°C
35°C
40°C
46°C
TC
SC
PI
TC
SC
PI
TC
SC
PI
TC
SC
PI
TC
SC
PI
TC
SC
PI
640 /
570
16°C
21°C
4.98 3.43 1.45 4.80 3.34 1.57 4.63 3.25 1.70 4.44 3.16 1.84 4.08 2.94 2.00 3.76 2.77 2.20
24°C
4.99 4.11 1.45 4.81 4.02 1.57 4.63 3.92 1.70 4.45 3.82 1.84 4.09 3.57 2.00 3.78 3.37 2.21
27°C
5.03 4.66 1.45 4.86 4.55 1.57 4.69 4.45 1.70 4.51 4.33 1.85 4.16 4.03 2.01 3.87 3.79 2.21
30°C
5.18 5.18 1.46 5.03 5.03 1.58 4.88 4.88 1.72 4.72 4.72 1.86 4.38 4.38 2.02 4.10 4.10 2.23
19°C
24°C
5.49 3.20 1.47 5.30 3.12 1.60 5.11 3.04 1.73 4.90 2.95 1.88 4.51 2.75 2.03 4.17 2.59 2.24
27°C
5.50 3.67 1.47 5.30 3.58 1.60 5.11 3.50 1.73 4.91 3.42 1.88 4.51 3.20 2.04 4.17 3.03 2.24
30°C
5.51 4.52 1.48 5.32 4.43 1.60 5.13 4.33 1.73 4.93 4.23 1.88 4.54 3.95 2.04 4.21 3.74 2.25
33°C
5.57 5.57 1.48 5.39 5.39 1.60 5.22 5.22 1.74 5.04 5.04 1.88 4.66 4.66 2.05 4.36 4.36 2.26
22°C
27°C
6.04 3.14 1.50 5.84 3.06 1.63 5.62 2.98 1.76 5.40 2.90 1.91 4.97 2.70 2.07 4.60 2.55 2.29
30°C
6.05 3.82 1.50 5.84 3.74 1.63 5.62 3.66 1.76 5.40 3.57 1.91 4.97 3.34 2.07 4.60 3.17 2.29
33°C
6.05 4.46 1.50 5.84 4.38 1.63 5.63 4.29 1.76 5.41 4.20 1.91 4.98 3.95 2.08 4.61 3.75 2.29
36°C
6.07 5.06 1.50 5.87 4.96 1.63 5.66 4.86 1.77 5.46 4.75 1.92 5.03 4.45 2.08 4.68 4.22 2.29
675 /
640
16°C
21°C
5.18 3.58 1.46 4.99 3.48 1.58 4.80 3.39 1.71 4.61 3.30 1.86 4.23 3.07 2.02 3.90 2.89 2.22
24°C
5.20 4.34 1.47 5.01 4.24 1.58 4.82 4.14 1.72 4.63 4.03 1.86 4.25 3.76 2.02 3.93 3.55 2.23
27°C
5.26 4.93 1.47 5.08 4.82 1.59 4.91 4.69 1.72 4.73 4.55 1.87 4.37 4.23 2.03 4.07 3.96 2.24
30°C
5.48 5.48 1.48 5.32 5.32 1.60 5.16 5.16 1.74 4.99 4.99 1.89 4.62 4.62 2.05 4.32 4.32 2.26
19°C
24°C
5.71 3.38 1.49 5.50 3.30 1.61 5.30 3.21 1.75 5.08 3.12 1.89 4.67 2.91 2.05 4.31 2.74 2.26
27°C
5.72 3.90 1.49 5.51 3.81 1.61 5.31 3.72 1.75 5.09 3.64 1.89 4.68 3.40 2.05 4.33 3.22 2.26
30°C
5.74 4.81 1.49 5.54 4.70 1.61 5.35 4.60 1.75 5.14 4.49 1.90 4.73 4.19 2.06 4.39 3.96 2.27
33°C
5.84 5.84 1.50 5.66 5.66 1.62 5.48 5.48 1.76 5.30 5.30 1.91 4.91 4.91 2.07 4.59 4.59 2.29
22°C
27°C
6.27 3.31 1.52 6.05 3.24 1.64 5.83 3.15 1.78 5.59 3.07 1.93 5.14 2.86 2.09 4.75 2.70 2.31
30°C
6.28 4.07 1.52 6.06 3.98 1.64 5.83 3.89 1.78 5.60 3.80 1.93 5.15 3.56 2.09 4.76 3.38 2.31
33°C
6.29 4.76 1.52 6.07 4.67 1.64 5.85 4.58 1.78 5.62 4.48 1.93 5.17 4.20 2.10 4.79 3.99 2.31
36°C
6.33 5.38 1.52 6.12 5.28 1.65 5.91 5.17 1.79 5.70 5.05 1.94 5.25 4.73 2.10 4.90 4.46 2.32
700 /
650
16°C
21°C
5.37 3.73 1.48 5.17 3.64 1.60 4.98 3.54 1.73 4.77 3.44 1.87 4.37 3.21 2.03 4.03 3.02 2.24
24°C
5.40 4.53 1.48 5.20 4.43 1.60 5.01 4.32 1.73 4.81 4.20 1.88 4.41 3.92 2.04 4.08 3.70 2.24
27°C
5.49 5.20 1.48 5.31 5.06 1.60 5.13 4.92 1.74 4.94 4.77 1.89 4.57 4.42 2.05 4.26 4.12 2.26
30°C
5.76 5.76 1.50 5.59 5.59 1.62 5.42 5.42 1.76 5.24 5.24 1.91 4.85 4.85 2.07 4.53 4.53 2.29
19°C
24°C
5.91 3.58 1.50 5.70 3.49 1.62 5.48 3.40 1.76 5.26 3.31 1.91 4.83 3.08 2.07 4.46 2.91 2.28
27°C
5.93 4.14 1.50 5.72 4.05 1.63 5.50 3.95 1.76 5.28 3.85 1.91 4.85 3.60 2.07 4.48 3.41 2.28
30°C
5.98 5.10 1.50 5.77 4.98 1.63 5.56 4.87 1.77 5.35 4.75 1.91 4.92 4.43 2.08 4.57 4.18 2.29
33°C
6.11 6.11 1.51 5.93 5.93 1.64 5.75 5.75 1.78 5.56 5.56 1.93 5.15 5.15 2.10 4.81 4.81 2.32
22°C
27°C
6.49 3.50 1.53 6.26 3.42 1.66 6.02 3.34 1.79 5.78 3.25 1.95 5.31 3.03 2.11 4.91 2.86 2.32
30°C
6.50 4.32 1.53 6.27 4.23 1.66 6.03 4.14 1.80 5.79 4.05 1.95 5.32 3.79 2.11 4.92 3.59 2.33
33°C
6.52 5.06 1.53 6.30 4.97 1.66 6.07 4.87 1.80 5.83 4.76 1.95 5.36 4.46 2.12 4.97 4.23 2.33
36°C
6.58 5.71 1.53 6.38 5.61 1.66 6.16 5.48 1.80 5.93 5.35 1.96 5.48 4.99 2.13 5.11 4.70 2.35
Model: FDYM20CXV1 - RY18CXV1 / FDYB20CXV1 - RY18CXV1
Heating Mode
ID DB
Outdoor WB
-9°C
-6°C
-5°C
6°C
12°C
15°C
18°C
TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW)
15°C
2.597
2.597
3.151
3.151
3.335
3.335
5.366
5.366
6.474
6.474
7.028
7.028
7.582
7.582
17°C
2.556
2.556
3.094
3.094
3.274
3.274
5.299
5.299
6.299
6.299
6.833
6.833
7.367
7.367
19°C
2.516
2.516
3.038
3.038
3.213
3.213
5.231
5.231
6.124
6.124
6.637
6.637
7.151
7.151
21°C
2.475
2.475
2.982
2.982
3.151
3.151
5.164
5.164
5.948
5.948
6.442
6.442
6.935
6.935
23°C
2.447
2.447
2.929
2.929
3.090
3.090
4.958
4.958
5.773
5.773
6.246
6.246
6.720
6.720
25°C
2.419
2.419
2.876
2.876
3.028
3.028
4.751
4.751
5.597
5.597
6.051
6.051
6.504
6.504
27°C
2.390
2.390
2.823
2.823
2.967
2.967
4.545
4.545
5.422
5.422
5.855
5.855
6.289
6.289
Frost Region
Remark:
AFR: Air
fl
ow rate (CFM)
EWB: Entering Wet Bulb Temp. (°C)
EDB: Entering Dry Bulb Temp. (°C)
TC: Total Cooling / Heating Capacity (kW)
SC: Sensible Cooling / Heating Capacity (kW)
PI: Power Input (kW)
Notes
:
1. Ratings shown are net capacities.
2.
shows nominal capacities.
3. Direct interpolation is permissible. Do not extrapolate.
4. Unit is able to operate at ambient from 19°C to 46°C DB (cooling) / -9°C to 18°C WB (heating) without pressure trip.
DAIKIN_R22 CC.indb 84
DAIKIN_R22 CC.indb 84
11/8/2012 11:40:15 AM
11/8/2012 11:40:15 AM
Содержание FDB10CXV1
Страница 2: ......
Страница 129: ...Outlines Dimensions 126 Model FD Y M28CXV1 Note Dimension in mm Model FD Y M38CXV1 Note Dimension in mm ...
Страница 133: ...130 Wiring Diagrams Wiring Diagrams Cooling Only Indoor Unit Model FDM10CXV1 FDB10CXV1 Outdoor Unit Model R10CXV1 ...
Страница 134: ...131 Wiring Diagrams Indoor Unit Model FDM15CXV1 FDB15CXV1 Outdoor Unit Model R15CXV1 ...
Страница 135: ...132 Wiring Diagrams Indoor Unit Model FDM20 25CXV1 FDB20 25CXV1 Outdoor Unit Model R20 25CXV1 ...
Страница 136: ...133 Wiring Diagrams Indoor Unit Model FDM28 30CXV1 FDB30CXV1 Outdoor Unit Model R28CXV1 ...
Страница 137: ...134 Wiring Diagrams Indoor Unit Model FDM28 30CXV1 FDB30CXV1 Outdoor Unit Model R30DXV1 ...
Страница 138: ...135 Wiring Diagrams Indoor Unit Model FDM28 30CXV1 FDB30CXV1 Outdoor Unit Model R30DXY1 ...
Страница 139: ...136 Wiring Diagrams Indoor Unit Model FDM38 40CXV1 FDB40CXV1 Outdoor Unit Model R35 40DXV1 ...
Страница 140: ...137 Wiring Diagrams Indoor Unit Model FDM38 40 50CXV1 FDB40 50CXV1 Outdoor Unit Model R40 50DXY1 ...
Страница 141: ...138 Wiring Diagrams Indoor Unit Model FDM60CXV1 FDB60CXV1 Outdoor Unit Model R61DXY1 ...
Страница 142: ...139 Wiring Diagrams Heatpump Indoor Unit Model FDYM10CXV1 FDYB10CXV1 Outdoor Unit Model RY10CXV1 ...
Страница 143: ...140 Wiring Diagrams Indoor Unit Model FDYM15CXV1 FDYB15CXV1 Outdoor Unit Model RY15CXV1 ...
Страница 144: ...141 Wiring Diagrams Indoor Unit Model FDYM20 25CXV1 FDYB20 25CXV1 Outdoor Unit Model RY18 20 25CXV1 ...
Страница 145: ...142 Wiring Diagrams Indoor Unit Model FDYM28 30CXV1 FDYB30CXV1 Outdoor Unit Model RY28CXV1 ...
Страница 146: ...143 Wiring Diagrams Indoor Unit Model FDYM28 30CXV1 FDYB30CXV1 Outdoor Unit Model RY30DXV1 ...
Страница 147: ...144 Wiring Diagrams Indoor Unit Model FDYM28 30CXV1 FDYB30CXV1 Outdoor Unit Model RY30DXY1 ...
Страница 148: ...145 Wiring Diagrams Indoor Unit Model FDYM38 40CXV1 FDYB40CXV1 Outdoor Unit Model RY35 40DXV1 ...
Страница 149: ...146 Wiring Diagrams Indoor Unit Model FDYM38 40 50CXV1 FDYB40 50CXV1 Outdoor Unit Model RY40 50DXY1 ...
Страница 150: ...147 Wiring Diagrams Indoor Unit Model FDYM60CXV1 FDYB60CXV1 Outdoor Unit Model RY61DXY1 ...
Страница 159: ......