14 Troubleshooting

Installation and operation manual

15

250AXVEB
Split system air conditioners
3P580564-1 – 2019.04

Malfunction

Measure

Operation stops
suddenly. (Operation
lamp blinks.)

▪ Check  if  the  air  filter  is  clogged  (see

"13.2.2  To  clean  the  air  filter"  on
page 13

).

▪ Check  if  air  inlet  or  outlet  of  outdoor  or

indoor  unit  is  not  blocked  by  obstacles.
Remove  any  obstacles,  turn  the  breaker
OFF and back ON. If the lamp still blinks,
contact your dealer.

▪ Check  if  all  indoor  units  connected  to

outdoor  unit  in  the  multi-system  are
operating in the same mode.

An abnormal function
happens during
operation.

▪ The  air  conditioner  may  malfunction

because of lightning or radio waves. Turn
the breaker OFF and back ON.

If  after  checking  all  above  items,  it  is  impossible  to  fix  the  problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).

14.1

Symptoms that are NOT system
malfunctions

The following symptoms are NOT system malfunctions:

14.1.1

Symptom: The system does not operate

▪ The  air  conditioner  does  not  start  immediately  after  the  ON/OFF

button  on  the  user  interface  is  pressed.  If  the  operation  lamp
lights, the air conditioner is in normal condition. It does not restart
immediately because one of its safety devices actuates to prevent
the air conditioner from being overloaded. The air conditioner will
turn on again automatically after 3 minutes.

▪ The  air  conditioner  does  not  start  immediately  after  the  power

supply  is  turned  on.  Wait  1  minute  until  the  microcomputer  is
prepared for operation.

▪ The  air  conditioner  does  not  restart  immediately  when  the

temperature  setting  button  is  returned  to  its  former  position  after
pushing. It does not restart immediately because one of its safety
devices  actuates  to  prevent  the  air  conditioner  from  being
overloaded.  The  air  conditioner  will  turn  on  again  automatically
after 3 minutes.

▪ The  outdoor  unit  has  stopped.  This  is  because  the  room

temperature  has  reached  the  set  temperature.  The  unit  switches

to fan operation. "

" (external control icon) is displayed on

the  user  interface  and  the  actual  operation  is  different  from  the
user  interface  setting.  For  multi-split  models,  the  microcomputer
executes  the  following  control  depending  on  the  operation  mode
of other indoor units.

▪ The fan speed is different from the setting. Pressing the fan speed

control  button  does  not  change  the  fan  speed.  When  the  room
temperature  reaches  the  set  temperature  in  heating  mode  or  the
unit’s  maximum  capacity  is  reached,  the  outdoor  unit  will  stop
operation  and  the  indoor  unit  will  operate  in  fan  only  mode  (low
fan  speed).  In  case  of  multi-split,  the  indoor  unit  alternately
operates  in  fan  stop  mode  and  fan  only  mode  (LL=  low  fan
speed).  This  is  to  prevent  the  cool  air  from  being  blown  directly
onto anyone present in the room.

14.1.2

Symptom: White mist comes out of a unit
(Indoor unit)

▪ When humidity is high during cooling operation (in oily and dusty

places). If the interior of an indoor unit is extremely contaminated,
the  temperature  distribution  inside  a  room  becomes  uneven.  It  is

necessary to clean the interior of the indoor unit. Ask your dealer
for details on cleaning the unit. This operation requires a qualified
service person.

▪ When  the  air  conditioner  is  changed  over  to  heating  operation

after  defrost  operation.  Moisture  generated  by  defrost  becomes
steam and exits.

14.1.3

Symptom: Noise of air conditioners
(indoor unit)

▪ A  "ringing"  sound  is  heard  after  the  unit  is  started.  This  sound  is

generated by the temperature regulator working. It will quiet down
after about a minute.

▪ A  continuous  low  "hissing"  sound  is  heard  when  the  system  is  in

cooling  or  defrost  operation.  This  is  the  sound  of  refrigerant  gas
flowing through both indoor and outdoor units.

▪ A  hissing  sound  which  is  heard  at  the  start  or  immediately  after

stopping  operation  or  defrost  operation.  This  is  the  noise  of
refrigerant caused by flow stop or flow change.

▪ A "squeaking" sound is heard when the system is in operation or

after  the  stop  of  operation.  Expansion  and  contraction  of  plastic
parts caused by temperature change makes this noise.

14.1.4

Symptom: Dust comes out of the unit

When  the  unit  is  used  for  the  first  time  in  a  long  time.  This  is
because dust has gotten into the unit.

14.1.5

Symptom: The units can give off odours

The  unit  can  absorb  the  smell  of  rooms,  furniture,  cigarettes,  etc.,
and then emit it again.

14.1.6

Symptom: The display shows "88"

This  is  the  case  immediately  after  the  main  power  supply  switch  is
turned  on  and  means  that  the  user  interface  is  in  normal  condition.
This continues for 1 minute.

14.1.7

Symptom: The operation stopped
suddenly (Operation lamp is on)

The  air  conditioner  may  stop  for  system  protection  due  to  large
voltage fluctuation. It automatically resumes operation after about 3
minutes.

14.1.8

Symptom: The outdoor fan rotates while
the air conditioner is not in operation

After  operation  has  stopped.

  The  outdoor  fan  continues  to

rotate for another 30 seconds for system protection.

While the air conditioner is not in operation.

 When the outdoor

temperature  is  very  high,  the  outdoor  fan  starts  to  rotate  for
system protection.

14.1.9

Symptom: The heating operation stops
suddenly and a flowing sound is heard

The system is removing frost on the outdoor unit. You should wait for
about 3 to 8 minutes.

Содержание FDA200AXVEB

Страница 1: ...Installation and operation manual Split system air conditioners English Installation and operation manual Split system air conditioners FDA200AXVEB FDA250AXVEB...

Страница 2: ...na imi navodili on vastavuses j rgmis t e standardi te ga v i teiste normatiivsete dokumentidega kui neid kasutatakse vastavalt meie juhenditele atitinka emiau nurodytus standartus ir arba kitus normi...

Страница 3: ...Symptom The units can give off odours 15 14 1 6 Symptom The display shows 88 15 14 1 7 Symptom The operation stopped suddenly Operation lamp is on 15 14 1 8 Symptom The outdoor fan rotates while the a...

Страница 4: ...er bracket d Screws for duct flanges M5 12 e Hexagon head bolt M10 40 f Attached piping with sealing g Tie wrap h Spring washer 3 About the units and options 3 1 System layout INFORMATION The followin...

Страница 5: ...e the ceiling before installing the unit Suspension bolts Use M10 suspension bolts for installation Attach the hanger bracket to the suspension bolt Fix it securely using a nut and washer from the upp...

Страница 6: ...o the unit using a duct system make sure there are no operating ignition sources example open flames an operating gas appliance or an operating electric heater in case the floor area is less than Amin...

Страница 7: ...ction attached to the unit d Indoor unit 2 Connect the gas piping using the attached piping accessory Fix it to the unit using hexagon head bolts M10 40 accessory and spring washers accessory Place se...

Страница 8: ...each other In order to avoid any electrical interference the distance between both wirings should ALWAYS be at least 50 mm NOTICE Be sure to keep the power line and transmission line apart from each o...

Страница 9: ...the voltage on the identification label of the unit There are NO loose connections or damaged electrical components in the switch box There are NO damaged components or squeezed pipes on the inside o...

Страница 10: ...ailable on the Daikin extranet authentication required 9 1 Wiring diagram 9 1 1 Unified wiring diagram legend For applied parts and numbering refer to the wiring diagram on the unit Part numbering is...

Страница 11: ...H C Buzzer C Capacitor AC CN E HA HE HL HN HR MR _A MR _B S U V W X A K R_ Connection connector For the user 10 About the system INFORMATION This appliance is intended to be used by expert or trained...

Страница 12: ...nual of the installed user interface 12 Operation 12 1 Operation range For combination with R410A outdoor unit refer to the following table Outdoor units Cooling Heating RZQ200 250 Outdoor temperature...

Страница 13: ...clean filter notification Clean the air filter when the notification is displayed If the dirt becomes impossible to clean change the air filter How to clean the air filter 1 Remove the screws on the...

Страница 14: ...ation and shut off the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electric shock or fire Contact your dealer The system MU...

Страница 15: ...the outdoor unit will stop operation and the indoor unit will operate in fan only mode low fan speed In case of multi split the indoor unit alternately operates in fan stop mode and fan only mode LL l...

Страница 16: ...ers 3P580564 1 2019 04 15 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...3P580564 1 2019 04 Copyright 2019 Daikin...

Отзывы: