5
Wiring diagrams
3TW25086-1
FCQ-B7
33H
Float switch
A1P
Printed circuit board
C1R
Capacitor (M2F)
HAP
Light emitting diode (service monitor green)
M1A
Motor (swing flap)
M2F
Motor (indoor fan)
M3P
Motor (drain pump)
Q1F
Thermo switch (M2F embedded)
R1T
Thermistor (air)
R2T
Thermistor (liquid)
R3T
Thermistor (coil)
RyP
Magnetic relay (M3P)
SS1
Selector switch (emergency)
T1R
Transformer (220-240V/22V)
X1M
Terminal strip (power)
X2M
Terminal strip (control)
PC
Phase control circuit
RC
Signal receiver circuit
TC
Signal transmission circuit
Wired remote control
SS1
Selector switch (main/sub)
Receiver / display unit (attached to infrared remote control)
A2P,A3P Printed circuit board
BS
Push button (on/off)
H1P
Light emitting diode (on-red)
H2P
Light emitting diode (timer-green)
H3P
Light emitting diode (filter sign-red)
H4P
Light emitting diode (defrost-orange)
SS1
Selector switch (main/sub)
SS2
Selector switch (wireless address set)
Indoor
Outdoor
Wired remote
control
Terminals for operation indicator
Note 3
Receiver / display unit
Adapter for
wiring
Fan operation
compressor operation
Notes
1. Use copper conductors only.
2. When using the central remote control, see manual for
connection to the unit.
3. X24A is connected when the remote control kit is used.
4. The infrared remote controller model varies according to
the combination system. See technical data and catalogs
before connecting.
g
Field wiring
D
Terminal
F
: Connector
h
: Wire clamp
b
: Protective earth (screw)
Colours
BLK: Black / WHT: White / RED: Red / YLW: Yellow
Adapter for wiring
RyC,RyF
Magnetic relay
Connector for optional parts
X60A,X61A Connector (interface adapter for sky air series)
X33A
Connector (adapter for wiring)
X35A
Connector (group control adapter)
X40A
Connector (remote ON/OFF forced OFF)
Switch box
Simultaneous operation system
Remote
controller
Master
Slave
Outdoor
unit
•
4-Way Blow Ceiling Mounted Cassette
•
R-410A
•
FCQ35-60B7V1B
5
7
•
Split - Sky Air
•