background image

22

HOW TO CLEAN THE AIR FILTER

1.  Open the suction grille.

•  Use tooling such as test pan to open all 

three grille fi xture cover.

•  Push the middle 

grille fi xture to unlock 
the suction grille fi rst 
and followed by the 
side fi xtures.

•  Open the suction grille gently and 

ensure the safety strings are hooked up 
to the metal bar.

2.  Remove the air filter.

(2) Remove the air 

fi lter protrusions 
from the upper side 
of the discharge 
panel.

1

2

Air filter clips

Air filter clips

Air filter 

protrusions

2

(1) Push the two clips 

at the end of the 
air fi lter to unlock it.

3.  Clean the air filter.

A) Using a vacuum cleaner
B) Washing with water

• When the air fi lter is very dirty, use 

soft brush and neutral detergent.

• Remove water and dry in the shade.

(Ensure to remove PM2.5 fi lter before 
cleaning the air fi lter)

A)

B)

NOTES

• Do not wash the air fi lter with water of 50°C 

or higher. It may cause discoloration and 
deformation.

• When drying the fi lter, do not heat it with fi re.

It may cause burning.

• Do not use such as gasoline, benzine, thinner, 

polishing powder and liquid insecticide sold 
in the market. It may cause discoloration and 
deformation.

4.  Fix the air filter.

(1)  Insert the air fi lter protrusions to the 

upper side slots of the discharge panel.

(2)  Push the air fi lter upwards to hook the 

clips to discharge panel.

1

2

Air filter 
protrusions

5.  Shut the suction grille.

1

2

Grille Fixture

Side clip 
(in 2 locations)

(1)  Slowly raise suction grille and press at 

3 points of the grille fi xture part.

(2)  Gently press at 2 sides shown to hook 

up to side clips of the top panel.

1-OM-NCCK-DAIKIN-3P661416-2-EN.indd   22

1-OM-NCCK-DAIKIN-3P661416-2-EN.indd   22

10/9/2021   2:04:06 PM

10/9/2021   2:04:06 PM

www.ttair.co.th | Tel : 02-385-0728 | E-mail : [email protected] | LINE ID : @ttair

Содержание FCFV50A

Страница 1: ...OPERATION MANUAL 3P661416 2 B MODELS FCFV50A FCFV60A FCFV85A FCFV100A FCFV125A CVR OM NCCK DAIKIN 3P661416 2 B indd 1 CVR OM NCCK DAIKIN 3P661416 2 B indd 1 5 10 2021 4 19 21 PM 5 10 2021 4 19 21 PM w...

Страница 2: ...23 How to clean top panel and remote controller 24 PM2 5 Replacement 24 Cleaning before and after seasonal use 24 NOT MALFUNCTION OF THE AIR CONDITIONER 25 TROUBLESHOOTING 26 MEMO 28 Note Illustratio...

Страница 3: ...aters kerosene heaters or gas range If the air conditioner is not cooling properly the refrigerant may be leaking so call your dealer When carrying out repairs accompanying adding refrigerant check th...

Страница 4: ...or product damage Do not give impact to the indoor and outdoor units or otherwise product damage may result Do not place objects around the indoor unit Doing so may have an adverse influence on the pe...

Страница 5: ...ings Places where snow may block the outdoor unit The indoor unit is at least 1m away from any television or radio set unit may cause interference with the picture or sound The drain from the outdoor...

Страница 6: ...ransmission direct the transmitter to the indoor unit Note that in condition where there is an obstacle that blocks between the transmitter and the indoor unit signal transmission might not be success...

Страница 7: ...ctly To set the batteries 1 Release the battery cover at the back of the remote controller 2 Insert two dry batteries LR03 AAA 3 Set the battery cover as before Disposal Requirements The batteries sup...

Страница 8: ...the remote controller on the holder Remote controller holder Screws Remote controller PREPARATION BEFORE OPERATION About remote controller Do not drop nor wet the remote controller Never expose the r...

Страница 9: ...sent time is 8 o clock in the morning will be displayed C 1 3 2 PREPARATION BEFORE OPERATION Notes Remote controller is automatically in clock setting mode upon battery insertion Users are advised to...

Страница 10: ...The air conditioner operates to control the room humidity by regulating the indoor unit fan speed Therefore manual adjustment of the fan speed in DRY mode is not available To start operation 1 Press b...

Страница 11: ...ature setting 4 Press button The temperature segments on LCD display shall change whenever or button is pressed Operating Mode COOL DRY FAN Set Temperature Range 16 C 30 C Not applicable Press simulta...

Страница 12: ...FAN mode LOW FAN HIGH FAN MEDIUM FAN Fan speed setting not available in DRY mode C FA N 5 Notes on QUIET operation Indoor unit operating sound will appear to be lower during QUIET operation The coolin...

Страница 13: ...yed on the LCD To switch off the STREAMER operation 2 Press button will disappear from the LCD C 1 OM NCCK DAIKIN 3P661416 2 EN indd 12 1 OM NCCK DAIKIN 3P661416 2 EN indd 12 10 9 2021 2 04 06 PM 10 9...

Страница 14: ...on only available in COOL mode ECO OPERATION To start ECO operation 1 Press button will be displayed on the LCD To cancel ECO operation 2 Press button will disappear from the LCD The previous setting...

Страница 15: ...tion is started it will temporarily override the operation of other functions for 20 minutes POWERFUL operation will be stopped if fan speed is adjusted Priority will be given to the last button press...

Страница 16: ...s operation automatically adjust the set temperature of the air conditioner to provide a comfort sleeping environment 0 5 1 0 C 2 0 C 1 5 C 0 5 C 1 0 5 2 0 2 5 1 0 0 1 hour Enable SLEEP function Set T...

Страница 17: ...ndication lights off Cool mode default Light blue press C Notes on indoor unit indication display For operating mode status indication display COOL mode Light blue TIMER ON OFF Yellow ECO mode Green 1...

Страница 18: ...the off timer setting Holding down or button rapidly increases or decreases the time display 3 Press button again OFF stop blinking the OFF TIMER set will be displayed To cancel OFF TIMER operation 4...

Страница 19: ...he ON TIMER set will be displayed To cancel ON TIMER operation 4 Press button to cancel the ON TIMER C ON Notes on TIMER operation ON TIMER setting is sharing the same segment with CLOCK setting on th...

Страница 20: ...nt from the indoor unit indicates a non corresspondence error code A long beep acknowledgement from the indoor unit indicates a correspondence error code User shall not attempt to repair or modify the...

Страница 21: ...mp abnormal C4 Indoor heat exchanger 1 thermistor short open C9 Indoor room thermistor short open F6 Compressor overload 1 OM NCCK DAIKIN 3P661416 2 EN indd 20 1 OM NCCK DAIKIN 3P661416 2 EN indd 20 1...

Страница 22: ...es When working at a high place give caution to your footing If the scaffold is unstable it may cause injuries due to fall and stumbling NOTES Do not remove the air filter unless for cleaning It may c...

Страница 23: ...leaning the air filter A B NOTES Do not wash the air filter with water of 50 C or higher It may cause discoloration and deformation When drying the filter do not heat it with fire It may cause burning...

Страница 24: ...oam at the suction of the top panel Indication mark on foam of top panel Suction grille aligned according to marking Suction grille 2 After aligned push the suction grille downwards slightly for anoth...

Страница 25: ...the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles may cause a reduction in the fan speed which may decrease functionality cause an increase in operatio...

Страница 26: ...es a qualified service person Check the usage environment 3 NOISE OF AIR CONDITIONERS A low continuous flow Shuh sound which is heard when the air conditioner is in the COOLING or a trickling sound wh...

Страница 27: ...n this may cause dew condensation at the air outlet 3 The air conditioner operates but it does not sufficiently cool or heat Check if the air inlet or outlet of outdoor or indoor unit is blocked by ob...

Страница 28: ...er must be repaired by a qualified service person WARNING When the air conditioner is malfunctioning giving off a burning odour etc turn off power to the air conditioner and contact your local dealer...

Отзывы: