5
FAN OPERATION .................................. “
”
DRY OPERATION.................................. “
”
•
The function of this program is to decrease the
humidity in your room with the minimum tem-
perature decrease.
•
Micro computer automatically determines
TEMPERATURE and FAN SPEED.
•
This system does not go into operation if the
room temperature is below 16°C.
Refer to figure 3 on page [1]
•
For cooling only type, “COOLING”, “FAN” and
“DRY” operation are able to select.
ON/OFF
Press ON/OFF button
OPERATION lamp lights up or goes off and the sys-
tem starts or stops OPERATION.
[EXPLANATION OF HEATING OPERATION]
DEFROST OPERATION
•
As the frost on the coil of an outdoor unit increase,
heating effect decreases and the system goes
into DEFROST OPERATION.
•
The indoor unit fan stops and the remote control-
ler display shows “
”.
•
After 6 to 8 minutes (maximum 10 minutes) of
DEFROST OPERATION, the system returns to
HEATING OPERATION.
Regarding outside air temperature and heat-
ing capacity
•
The heating capacity of the air conditioner
declines as the outside air temperature falls. In
such a case, use the air conditioner in combina-
tion with other heating systems.
•
A warm air circulating system is employed, and
therefore it takes some time until the entire room
is warmed up after the start of operation.
•
An indoor fan runs to discharge a gentle wind
automatically until the temperature inside the air
conditioner reaches a certain level. At this time,
the remote controller displays “
”. Leave it
as it stands and wait for a while.
•
When the warm air stays under the ceiling and
your feet are cold, we recommend that you use a
circulator (a fan to circulate the air inside the
room). For details, consult your dealer.
For programming TEMPERATURE and FAN
SPEED, follow the procedure shown below.
2
ADJUSTMENT
TEMPERATURE SETTING
Press TEMPERATURE SETTING button and
program the setting temperature.
Each time this button is pressed, setting
temperature rises 1°C.
Each time this button is pressed, setting
temperature lowers 1°C.
•
The setting is impossible for fan operation.
NOTE
•
The setting temperature range of the remote con-
troller is 16°C to 32°C.
FAN SPEED CONTROL
Press FAN SPEED CONTROL button.
High or Low fan speed can be selected.
The microchip may sometimes control the fan speed
in order to protect the unit.
Operate in the following order.
•
The timer is operated in the following two ways.
•
Programming the stop time (
) ....
The system stops operating after the set time has
elapsed.
•
Programming the start time (
) ....
The system starts operating after the set time has
elapsed.
•
The timer can be programmed a maximum of
72 hours.
•
The start and the stop time can be simultaneously
programmed.
TIMER MODE START/STOP
Press the TIMER MODE START/STOP button
several times and select the mode on the
display.
The display flashes.
For setting the timer stop .... “
”
For setting the timer start .... “
”
PROGRAM TIMER OPERATION
1
Содержание FBQ50BV1A
Страница 13: ...3P156215 7K EM06A004A 0607 FS...