d
Wires between the relays and X5M (AWG22 ORG)
e
Wires between the relays and X10M (AWG18 RED)
C
X5M
K1A K2A
X10M
C
9
10
5
6
1 2 3 4
a
b b
2
Connect the low voltage wiring as follows:
B
C
A
A
X5M.4
X5M.3
S4S
S4S
Smart Grid pulse meter
C
B
X5M
X5M
3
4
13
14
3
Connect the high voltage wiring as follows:
B
C
A
A
L
N
L
N
X10M.1
X10M.2
X10M.3
X10M.4
2
1
1
High voltage Smart Grid contact 1
2
High voltage Smart Grid contact 2
C
B
X10M
1 2 3 4
4
Fix the cables with cable ties to the cable tie mountings. If
necessary, bundle excessive cable length with a cable tie.
6.3.12
To connect the WLAN cartridge (delivered
as accessory)
[D]
Wireless gateway
1
Insert the WLAN cartridge into the cartridge slot on the user
interface of the indoor unit.
3