• Air Handling Unit Connection • Heat pump
3
• Air Handling Unit Connection • ERQ-AV1
2
Specifications
2-1 Nominal Capacity and Nominal Input
ERQ100A7V1B
ERQ125A7V1B
ERQ140A7V1B
Nominal Capacity
Cooling capacity
Standard
kW
11.2
14.0
15.5
Heating capacity
Standard
kW
12.5
16.0
18.0
For combination
indoor units + outdoor
units
EER
Nominal
3.99
3.42
COP
Nominal
4.56
4.15
3.94
2-2 Technical Specifications
ERQ100A7V1B
ERQ125A7V1B
ERQ140A7V1B
Capacity range
HP
4
5
6
PED category
Category 1
Casing
Colour
Daikin White
Material
Painted galvanized steel plate
Dimensions
Unit
Height
mm
1,345
Width
mm
900
Depth
mm
320
Packing
Height
mm
1,524
Width
mm
980
Depth
mm
420
Weight
Unit
kg
120
Packed Unit
kg
130
Packing
Material
Wood + EPS
Weight
kg
8
Heat Exchanger
Dimensions
Length
mm
857
Nr of Rows
2
Fin Pitch
mm
2
Nr of Passes
10
Face Area
m²
1.131
Nr of Stages
60
Tube type
Hi-XSS(8)
Fin
Type
Non-symmetric waffle louvre
Treatment
Corrosion resistant
Fan
Type
Propeller
Discharge direction
Horizontal
Quantity
2
Air Flow Rate
(nominal at 230V)
Cooling
m³/min
106
Heating
m³/min
102
105
Motor
Quantity
2
Model
Brushless DC motor
Motor
Speed (nominal)
Cooling
rpm
850/815
Heating
rpm
820/785
840/805
Fan
Motor
Output
W
70
Drive
Direct Drive
Compressor
Quantity
1
Motor
Model
JT100G-VDL
Type
Hermetically sealed scroll compressor
Speed
rpm
6,480
Motor Output
W
2.5
3.0
3.5
Starting Method
Direct on line
Crankcase
Heater
W
33
Operation Range
Cooling
Min
°CDB
-5
Max
°CDB
46
Heating
Min
°CWB
-20
Max
°CWB
15.5
Sound Level (nominal) Cooling
Sound Power
dBA
66
67
69
Sound Pressure
dBA
50
51
53
Heating
Sound Pressure
dBA
52
53
55