![Daikin ERGA06DAV3 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/daikin/erga06dav3/erga06dav3_installers-reference-manual_4087644046.webp)
8 Configuration
Installer reference guide
46
ERGA04~08DAV3(A) + 08S18+23DA
Daikin Altherma – Low temperature split
4P495249-1 – 2017.12
Possible actions on this screen
Change the value.
Go to the next setting.
Confirm changes and proceed.
8.3.7
Detailed screen with weather-dependent
curve
When weather dependent operation is active the desired tank
temperature is determined automatically depending on the averaged
outdoor temperature. When the outdoor temperature is lower the
tank temperature will need to be higher as the water pipes will be
colder and vice versa.
The weather-dependent curves are defined by two setpoints:
▪ Setpoint (X1, Y2)
▪ Setpoint (X2, Y1)
Weather-dependent curve:
X1
Y1
Y2
X2
Y
a
X
Possible actions on this screen
Go through the temperatures.
Change the temperature.
Go to the next temperature.
Confirm changes and proceed.
Item
Description
a
Possible weather dependent zones:
▪
: Main zone or additional zone heating
▪
: Domestic hot water
X, X1, X2
Outdoor ambient temperature
Y, Y1, Y2
Desired tank temperature or leaving water temperature.
The symbol shown here corresponds to the heat emitter
for that zone:
▪
: Underfloor heating
▪
: Fan coil unit
▪
: Radiator
▪
: Domestic hot water tank
8.3.8
Schedule screen: Example
This example shows how to set a room temperature schedule in
heating mode for the main zone.
INFORMATION
The procedures to program other schedules are similar.
To program the schedule
Example:
You want to program the following schedule:
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
Prerequisite:
The room temperature schedule is only available if
room thermostat control is active. If leaving water temperature
control is active, you can program the main zone schedule instead.
1
Go to the schedule.
2
Clear the contents of the schedule (optional).
3
Program the schedule for Monday.
4
Copy the schedule to the other weekdays.
5
Program the schedule for Saturday and copy it to Sunday.
6
Give the schedule a name.
To go to the schedule:
1
Go to [1.1]: Room > Schedule.
2
Set scheduling to Yes.
3
Go to [1.2]: Room > Heating schedule.
To clear the contents of the schedule:
1
Select the name of the current schedule.
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
2
Select Delete.
Edit
Delete
3
Select OK to confirm.
To program the schedule for Monday:
1
Select Monday.
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
2
Select Edit.
Delete
Copy
Edit
3
Use the left dial to select an entry and edit the entry
with the right dial. You can program up to 6 actions
each day.
0
6:00
8:30
17:30
20°C
18°C
22:00
--:--
18°C
--
21°C
12
24
Mon
4
Confirm the changes.
Содержание ERGA06DAV3