Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[9-00]
R/W ([2-
0C] ≠ 2)
R/O ([2-
0C] = 2)
[2-0C]=2:
37~60, step: 1°C
65°C
[2-0C]≠2:
37~55, step: 1°C
55°C
9.I
[9-01]
R/W
15~37°C, step: 1°C
25°C
9.I
[9-02]
R/W
18~22°C, step: 1°C
22°C
9.I
[9-03]
R/W
5~18°C, step: 1°C
5°C
9.I
[9-04]
R/W
1~4°C, step: 1°C
2°C
9.I
[9-05]
R/W
15~37°C, step: 1°C
25°C
9.I
[9-06]
R/W ([2-
0C] ≠ 2)
R/O ([2-
0C] = 2)
[2-0C]=2:
37~60, step: 1°C
65°C
[2-0C]≠2:
37~55, step: 1°C
55°C
9.I
[9-07]
R/W
5~18°C, step: 1°C
5°C
9.I
[9-08]
R/W
18~22°C, step: 1°C
22°C
9.I
[9-09]
R/W
1~18°C, step: 1°C
18°C
9.I
[9-0A]
R/W
[3-07]
~
[3-06]°C, step: 0,5°C
23°C
9.I
[9-0B]
R/W
[3-09]
~
[3-08]°C, step: 0,5°C
23°C
9.I
[9-0C]
R/W
1~6°C, step: 0,5°C
1 °C
9.I
[9-0D]
R/W
0~8, step:1
0 : No limitation
1~4 : 90~60% pump speed
5~8 : 90~60% pump speed during
sampling
6 80% pump speed
9.I
[9-0E]
6
9.I
[C-00]
R/W
0: Solar priority
1: Heat pump priority
9.I
[C-01]
0
9.I
[C-02]
R/W
0: Off
1: Direct (SH)
2: Indirect (DHW) (*3)
3: Indirect (DHW + SH)
9.I
[C-03]
R/W
-25~25°C, step: 1°C
0°C
9.I
[C-04]
R/W
2~10°C, step 1°C
3°C
9.I
[C-05]
R/W
1: 1 contact
2: 2 contacts
9.I
[C-06]
R/W
1: 1 contact
2: 2 contacts
9.I
[C-07]
R/W
0: Leaving water
1: External room thermostat
2: Room thermostat
9.I
[C-08]
R/W
0: No
1: Outdoor
2: Room
9.I
[C-09]
R/W
0: Abnormal
1: Normal
9.I
[C-0A]
0
9.I
[C-0B]
0
9.I
[C-0C]
0
9.I
[C-0D]
0
9.I
[C-0E]
0
9.I
[D-00]
R/W
0: None
1: BSH only
2: BUH only
3: All
9.I
[D-01]
R/W
0: No
1: Open
2: Closed
3: Smart Grid
9.I
[D-02]
R/W
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
9.I
[D-03]
R/W
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
9.I
[D-04]
R/W
0: No
1: Pwr consmp ctrl
9.I
[D-05]
R/W
0: No
1: Yes
9.I
[D-07]
R/W
0: No
1: Yes (DHW)
2: Yes (DHW + SH)
What is the allowed LWT undershoot during cooling start-up?
What is the mimimum desired LWT for add. zone in heating?
What is the mimimum desired LWT for main zone in heating?
What is the maximum desired LWT for main zone in cooling?
What is the room buffering temperature in heating?
What is the room buffering temperature in Cooling?
Bivalent hysteresis temperature.
What is the maximum desired LWT for main zone in heating?
--
Domestic heating water priority.
--
Is an external backup heat source connected?
Bivalent activation temperature.
What is the maximum desired LWT for add. zone in heating?
What is the mimimum desired LWT for add. zone in cooling?
What is the maximum desired LWT for add. zone in cooling?
Room temperature hysteresis.
Pump speed limitation
What is the unit control method in space operation?
--
--
What is the thermo request contact type for the add. zone?
What is the mimimum desired LWT for main zone in cooling?
Leaving water temperature overshoot temperature.
Which type of external sensor is installed?
What is the required alarm output contact type?
--
What is the thermo request contact type for the main zone?
Is the pump allowed to run if prefer. kWh rate PS is cut?
Is a solar kit connected?
Which type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
Is a demand PCB connected?
--
--
Which heaters are permitted if prefer. kWh rate PS is cut?
Contact type of preferential kWh rate PS installation?
(*1) 300 Tank_(*2) 500 Tank_
(*3) *X*_(*4) *H*_(*5) *B*_
(*6) *EKECBUA3V*_(*7) *EKECBUA6V*_(*8) *EKECBUA9W*_(*9) BUH less_
(*10) 04P_(*11) 08P
4P681207-1A - 2022.03