
4
|
Components
Service manual
58
RXJ20~50A + FTXJ-A(W)(S)(B)
Split Emura 3 R32
ESIE22-04 – 2022.04
c
f
b
a
d
e
a
Power supply terminal X1M
b
Power supply wiring bracket
c
Screw (ground wire)
d
Indoor unit main PCB
e
Switch box screw
f
Switch box
5
Disconnect the connectors of the indoor unit fan motor and the swing flap
motors from the indoor unit PCB.
6
Detach these wiring harnesses from the switch box.
7
Remove the screw and remove the switch box from the indoor unit.
8
To install the switch box, see
48].
To install the switch box
1
install the switch box in the correct location on the indoor unit.
c
f
b
a
d
e
a
Power supply terminal X1M
b
Power supply wiring bracket
c
Screw (ground wire)
d
Indoor unit main PCB
e
Switch box screw
f
Switch box
2
Route the connectors of the indoor unit fan motor and swing flap motors
inside the switch box and connect them to the indoor unit PCB.
3
Install and tighten the screw to secure the switch box.
draft – 22/04/2022 08:50
Содержание Emura 3 Series
Страница 98: ......
Страница 99: ......
Страница 100: ...draft 22 04 2022 08 50 ESIE22 04 2022 04 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...