Installation manual
8
EKRTWA
Room thermostat
4PW56101-1
6®
06
+
p
Minimum delay
between 2
heating cycles.
005
001
~
6® 04
/2
1 min.
07
+
o
Duration
proportional
band (cooling).
020
010
~
060
1 min.
08
+
o
Minimum "on"
time (cool
demand).
007
002
~
6® 07
/2
1 min.
09
+
o
Minimum delay
between 2
cooling cycles.
003
001
~
6® 07
/2
1 min.
10
Value of
proportional
band.
02.0
01.0
~
04.0
0.1°C
03.6
01.8
~
07.2
0.1°F
11
Not used
parameter
—
—
—
12
Upper setpoint
limitation.
37.0
22.0
~
37.0
0.5°C
99.0
72.0
~
99.0
0.5°F
13
Lower setpoint
limitation.
04.0
04.0
~
20.0
0.5°C
39.5
39.0
~
68.0
0.5°F
1st
code
2nd
code
Description
Default
Range
Step
1D_IM_4PW56101-1.book Page 8 Thursday, August 27, 2009 10:44 AM