Daikin EKHWS150D3V3 Скачать руководство пользователя страница 17

13 Glossary

Installation manual

17

EKHWS150~300D3V3
Domestic hot water tank with option kit for air to water heat pump
system
4P510672-1B – 2018.01

For EBLQ/EDLQ units only:

4

2

3

1

7 8

L N X2M

K3M

F2B

X6M

Q2L

E4H

1

2

4

3

b

a

c

L N

X8M

N

L

X4M

R5T

d

3 4

X8M

3 4

1 2

5

e

Y

L

N

M3S

a

Field supply

b

EKCB07CAV3 control box

c

Domestic hot water tank electrical box

d

Domestic hot water tank

e

3-way valve

E4H

Booster heater

F2B

Fuse booster heater (field supply)

K3M

Contactor booster heater

L

Live

M3S

3-way valve

N

Neutral

Q2L

Thermal protector booster heater

R5T

Thermistor domestic hot water

X2M

Terminal block

X4M

Terminal block

X6M

Terminals on booster heater

X8M

Terminal block (located in the control box)

X8M

Terminal block (field supply)
Protective ground

Field wiring

13

Glossary

Dealer

Sales distributor for the product.

Authorized installer

Technical  skilled  person  who  is  qualified  to  install  the
product.

User

Person  who  is  owner  of  the  product  and/or  operates  the
product.

Applicable legislation

All  international,  European,  national  and  local  directives,
laws,  regulations  and/or  codes  that  are  relevant  and
applicable for a certain product or domain.

Service company

Qualified  company  which  can  perform  or  coordinate  the
required service to the product.

Installation manual

Instruction  manual  specified  for  a  certain  product  or
application, explaining how to install, configure and maintain
it.

Operation manual

Instruction  manual  specified  for  a  certain  product  or
application, explaining how to operate it.

Maintenance instructions

Instruction  manual  specified  for  a  certain  product  or
application,  which  explains  (if  relevant)  how  to  install,
configure,  operate  and/or  maintain  the  product  or
application.

Accessories

Labels, manuals, information sheets and equipment that are
delivered  with  the  product  and  that  need  to  be  installed
according  to  the  instructions  in  the  accompanying
documentation.

Optional equipment

Equipment  made  or  approved  by  Daikin  that  can  be
combined  with  the  product  according  to  the  instructions  in
the accompanying documentation.

Field supply

Equipment NOT made by Daikin that can be combined with
the  product  according  to  the  instructions  in  the
accompanying documentation.

Содержание EKHWS150D3V3

Страница 1: ...ot water tank with option kit for air to water heat pump system English Installation manual Domestic hot water tank with option kit for air to water heat pump system EKHWS150D3V3 EKHWS180D3V3 EKHWS200...

Страница 2: ...a kui neid kasutatakse vastavalt meie juhenditele atitinka emiau nurodytus standartus ir arba kitus norminius dokumentus su s lyga kad yra naudojami pagal m s nurodymus tad ja lietoti atbilsto i ra ot...

Страница 3: ...ng on the domestic hot water tank 11 6 6 Finishing the domestic hot water tank installation 12 6 6 1 To close the domestic hot water tank 12 7 Commissioning 12 7 1 Overview Commissioning 12 7 2 Checkl...

Страница 4: ...the product containing at least information on maintenance repair work results of tests stand by periods Also at least following information MUST be provided at an accessible place at the product Inst...

Страница 5: ...k them WARNING After finishing the electrical work confirm that each electrical component and terminal inside the electrical components box is connected securely Make sure all covers are closed before...

Страница 6: ...t for the domestic hot water tank optional 1 a b 1 a Expansion vessel of 18 litres 3 4 Male BSP b Instruction sheet 4 About the units and options 4 1 Identification 4 1 1 Identification label Domestic...

Страница 7: ...the water circuit Non brass metallic piping When using non brass metallic piping insulate the brass and non brass properly so that they do NOT make contact with each other This to prevent galvanic cor...

Страница 8: ...being released and when solved press the reset button located on the thermal protector The power supply must be protected with the required safety devices i e a main switch a slow blow fuse on each p...

Страница 9: ...se electrical errors 6 4 5 To insulate the water piping The piping in the complete water circuit MUST be insulated to prevent reduction of the heating capacity 6 4 6 To connect the 3 way valve 1 Unpac...

Страница 10: ...k with the 2 tapping screws supplied 3 Install the jumper wire from the accessory bag in between terminals X2M 10 and X2M 11a see illustration below 4 Route the booster heater power supply cable comin...

Страница 11: ...or to control box terminals X8M 1 and X8M 2 8 Connect the wires of the thermistor cable to the control box terminals X2M 3 and X8M 4 9 Connect the earth wire of the control box terminal X4M to the swi...

Страница 12: ...g element 7 Re install the thermal protector to the tank 8 Connect the booster heater power supply cable see also wiring diagram sticker on the inside of the switch box lid A B N L 9 Fix the cable s u...

Страница 13: ...vice NOTICE Maintenance MUST be done by an authorized installer or service agent We recommend performing maintenance at least once a year However applicable legislation might require shorter maintenan...

Страница 14: ...ugh visual inspection of the unit and look for obvious defects such as loose connections or defective wiring 10 2 Precautions when troubleshooting WARNING When carrying out an inspection on the switch...

Страница 15: ...knob on the valve counter clockwise If you do not hear a clacking sound contact your local dealer In case the water keeps running out of the unit close both the water inlet and outlet shut off valves...

Страница 16: ...essure relief valve connection 3 4 BSP f Electrical connection box g Recirculation hole 3 4 BSP h Thermistor inserting tube ONLY for EKHWS200 12 2 Wiring diagram Domestic hot water tank For EHBH X uni...

Страница 17: ...on All international European national and local directives laws regulations and or codes that are relevant and applicable for a certain product or domain Service company Qualified company which can p...

Страница 18: ......

Страница 19: ......

Страница 20: ...4P510672 1B 2018 01 Copyright 2017 Daikin 4P510672 1 B 0000000Z...

Отзывы: