10.4.2 Using and programming schedules
About schedules
Depending on your system layout and installer configuration, schedules for
multiple controls may be available.
You can…
See…
Set if a specific control needs to act according
to a schedule.
"
Activation screen
Select which schedule you currently want to use for a specific control. The system
contains some predefined schedules. You can:
Consult which schedule is currently
selected.
"
Schedule/Control
" in
Program your own schedules if the
predefined schedules are not satisfactory.
The actions you can program are control
specific.
▪
"
Possible actions
" in
▪
Possible schedules
The table contains the following information:
▪
Schedule/Control
: This column shows you where you can consult the currently
selected schedule for the specific control. If needed, you can:
-
Program your own schedule. See
"10.4.3 Schedule screen: Example"
▪
Predefined schedules
: (if applicable) The predefined schedule in the system for
the specific control.
If needed, you can program your own schedule.
▪
Activation screen
: For most controls, a schedule is only effective if it activated in
its corresponding activation screen. This entry shows you where to activate it.
▪
Possible actions
: Actions you can use when programming a schedule.
Schedule/Control
Description
[5.5]
Tank
>
Schedule
Schedule for the domestic hot
water tank temperature for
your normal domestic hot
water needs.
Predefined schedules:
Not applicable
Activation screen
: Not applicable. This schedule
is automatically activated if the DHW mode is
one of the following:
▪
Schedule only
▪
Sc reheat
Possible actions
:
▪
Comfort
: When to start heating the tank to
the user-defined preset value [5.2]
Comfort
setpoint
.
▪
Eco
: When to start heating the tank to the
user-defined
preset
value
[5.3]
Eco
setpoint
.
▪
Stop
: When to stop heating the tank, even if
the desired tank temperature is not reached
yet.
Note:
In
Sc reheat
mode, the
system also takes the user-defined preset value
[5.4]
Reheat setpoint
into account.