11. DISPOSAL

At the end of use, the heat pumps must be disposed of in com-

pliance with current regulations.

 

ATTENTION!:  This  equipment  contains  fluori

-

nated greenhouse gases included in the Kyoto 

protocol. Maintenance and disposal operations 

must be carried out only by qualified personnel.

INFORMATION FOR USERS

Pursuant to Directives 2011/65/EU and 2012/19/EU 

on the restriction of the use of hazardous substanc-

es in electrical and electronic equipment, as well as 

the disposal of waste.

The crossed-out bin symbol on the equipment or on 

its packaging indicates that, at the end of its useful life, the prod

-

uct must be collected separately from other waste.

Therefore, at the end of its life, the user must give the equip-

ment to the appropriate recycling centers for electrical and 

electronic equipment, or return it to the dealer when purchasing 

new, equivalent type equipment, on a one-to-one basis.

Adequate separate waste collection for subsequent sending of 

the decommissioned equipment to environmentally compatible 

recycling, treatment and/or disposal helps prevent negative ef-

fects on the environment and health and favors the reuse and/or 

recycling of the materials that make up the equipment.

Unauthorized disposal of the product by the user involves the 

application of the administrative sanctions provided for by cur-

rent legislation.

The main materials that make up the equipment in question 

are:

•  steel
•  magnesium
•  plastic

•  copper
•  aluminum
•  polyurethane

12. PRODUCT SHEET

Descriptions

u.m. EKHHE200PCV3 EKHHE260PCV3 EKHHE200CV3 EKHHE260CV3

Declared load profile

L

XL

L

XL

Energy efficiency class for heating water in average weather conditions

A+

A+

A+

A+

Energy efficiency of water heating in % in average weather conditions

%

135

139

135

139

Annual energy consumption in kWh in terms of final energy in average 

weather conditions

kWh

758

1203

758

1203

Water heater thermostat temperature settings

°C

55

55

55

55

Inside sound power level Lwa in dB

dB

50

50

50

50

The water heater can only work during off-peak hours

NO

NO

NO

NO

Any specific precautions to be taken at the time of assembly, installation or 

maintenance of the water heater

See manual

Energy efficiency of water heating in % in coldest weather conditions

%

105

100

105

100

Energy efficiency of water heating in % in hottest weather conditions

%

147

148

147

148

Yearly energy consumption in kWh in terms of final energy in coldest 

weather conditions

kWh

979

1672

979

1672

Yearly energy consumption in kWh in terms of final energy in hottest 

weather conditions

kWh

698

1132

698

1132

Outside sound power level Lwa in dB

dB

49

49

49

49

Содержание EKHHE200CV3

Страница 1: ...EKHHE200CV3 EKHHE200PCV3 EKHHE260CV3 EKHHE260PCV3 User Installations and Maintenance Manual Domestic Hot Water Heat Pump Monobloc type...

Страница 2: ...floor 15 6 3 Aeraulic connections 15 6 4 Securing and connections of this appliance 17 6 5 Hydraulic connections 17 6 6 Integration with solar thermal system only for models EKHHE200PCV3 EKHHE260PCV3...

Страница 3: ...y with the appliance This appliance may be used by children 8 years of age or older and those with reduced physical sensory or mental capacity or lack of experience or knowledge if they are properly s...

Страница 4: ...fixing bracket provided for this purpose and adhesives are not considered to be a reliable fixing means This product is designed to be used at a maximum altitude of 2000 m Refer to description and il...

Страница 5: ...be attached to the water mains The minimum inlet water pressure for the correct operation of the appliance is 0 15 MPa 1 5 bar For models that incorporate a heat exchanger solar coil the circuit must...

Страница 6: ...d water open the hot water taps and then operate the drain valve of the safety device The pressure relief valve must be operated regularly to remove scale deposits and to ensure that it is not blocked...

Страница 7: ...ing symbols are used in the manual to highlight the most important information Caution Procedures to be followed Information Suggestions 2 1 Products Dear Customer Thank you for purchasing this produc...

Страница 8: ...ng operations use a forklift or an adequate pallet truck The packed equipment can be placed horizontally and back down to facilitate undoing the anchoring screws Unpacking must done carefully so as no...

Страница 9: ...ATTENTION Horizontal transport is allowed only for the last km according to that indicated see Positions not allowed for transport and han dling making sure supports are positioned in such a way at th...

Страница 10: ...gement for solar coil Inlet Only for models EKHHE200PCV3 EKHHE260PCV3 13 Prearrangement for solar coil outlet Only for models EKHHE200PCV3 EKHHE260PCV3 14 Steel tank with vitreous enamel coating accor...

Страница 11: ...CV3 UM A 1 G 250 250 250 250 mm B 490 493 mm C 1 2 G 600 600 600 600 mm D 705 785 705 785 mm E 1 G 876 5 1162 876 5 1162 mm G 1142 1427 1142 1427 mm H 1607 1892 1607 1892 mm I 3 4 G 250 250 mm L 3 4 G...

Страница 12: ...60 1960 W Rated current 8 5 8 5 8 5 8 5 A Total max absorbed power 2030 2030 2030 2030 W Max current 8 93 8 93 8 93 8 93 A Heating time 1 BOOST MODE 3 58 5 06 3 58 5 06 h min Storage Storage capacity...

Страница 13: ...r animals or serious dam age to property or the environment NB If the possibility of a product fault or failure can cause damage to people animals and property it is nec essary to provide for a separa...

Страница 14: ...installation The product must be installed in a suitable place i e to allow normal use and adjustment operations as well as routine and extraordinary maintenance The necessary operating space must th...

Страница 15: ...In addition to the spaces indicated in 6 1 the heat pump re quires adequate air ventilation Create a dedicated air channel as indicated in fig 12 Internal compartment Exterior fig 12 Example of air ou...

Страница 16: ...nt To ensure maximum product performance the grille must be selected from those with low pressure loss To avoid the formation of condensation water insulate the air extraction pipes and the ducted air...

Страница 17: ...the connection points Ref Function Model 200 l 260 l 1 Cold water inlet 1 G 2 Solar coil outlet 3 4 G 3 Solar coil inlet 3 4 G 4 Recirculation 3 4 G 5 Hot water outlet 1 G 6 Condensate drain 1 2 G A P...

Страница 18: ...ec tronic controller not supplied that has a voltage free contact type output to be connected to the DIG 1 input of the equipment see 6 7 1 Remote connections To use the equipment in this configuratio...

Страница 19: ...to verify conformity to the regulations in force and that the electrical system can suitably withstand the water heater s maximum power consumption val ues refer paragraph 4 2 for technical character...

Страница 20: ...s allows the equipment to be activated only when there is a signal coming from outside with prefer ential tariff If the electric contactor has a voltage free contact which closes when the preferential...

Страница 21: ...T1000 Solar collector Probe T5AL250V Solar thermal cut out fig 26 Equipment wiring diagram Description of connections available on the power board CN1 Air defrost and water NTC probes CN2 Not usable C...

Страница 22: ...place the ther mal cut out inside an adequate enclosure fixed to the wall Connect the thermal cut out in series with line L and neu tral N power supply connections of solar circulating pump for all po...

Страница 23: ...button lock function is automatically activated to prevent possible interactions with the water heater e g by children etc At the same time the backlighting level of the buttons and display decreases...

Страница 24: ...ation room if desired In automatic mode the fan will be adjusted to the minimum speed 7 5 6 HOLIDAY The display shows the symbol This mode is useful when away for a limited time and then au tomaticall...

Страница 25: ...30 min Anti legionella cycle activation time P29 0 23 h 23 h 7 6 2 Defrost function The display shows the symbol This equipment has an automatic evaporator defrost function which is activated when the...

Страница 26: ...Inlet air probe fault P04 P04 Evaporator inlet probe fault P05 P05 Evaporator outlet probe fault P06 P06 Compressor flow probe fault P07 P07 Solar collector probe fault P08 P08 High pressure protectio...

Страница 27: ...tons and pressing the and buttons together for 3 seconds The label of the first parameter is shown on the display with the letter A Pressing the button displays its value and pressing this button agai...

Страница 28: ...ifiable P4 Antilegionella duration 0 90 min 30 min Modifiable P5 Defrosting mode 0 compressor stop 1 hot gas 1 Modifiable P6 Electrical heater usage during defrosting 0 OFF 1 ON 0 Modifiable P7 Delay...

Страница 29: ...king period in AUTO mode for heating rate calculation 10 80 min 30 min Modifiable P32 Temperature threshold for electrical heater usage in AUTO mode 0 20 C 4 C Modifiable P33 Electronic expansion valv...

Страница 30: ...tact If not replace it with an IEC 60127 2 II certified time delay 5 A fuse Water cannot be heated via the heat pump in ECO or AUTOMATIC mode Switch the equipment off then switch it on again after a f...

Страница 31: ...powering it fig 28 9 2 Heating element safety thermostat reset This equipment has a manual reset safety thermostat connect ed in series with the heating element immersed in water which interrupts the...

Страница 32: ...ium is a weakly charged metal compared to the material of which the inside of the boiler is coated therefore it attracts first the negative charges that form with the heating of water consuming itself...

Страница 33: ...s that make up the equipment Unauthorized disposal of the product by the user involves the application of the administrative sanctions provided for by cur rent legislation The main materials that make...