Operation manual

5

EKHBH/XE008BA

Indoor unit for air to water heat pump system and options

4PW56302-1

26. DOMESTIC WATER HEATING BUTTON 

v

This button enables or disables heating of the domestic water.

This button is not used when the domestic hot water tank is not
installed.

27. WEATHER DEPENDENT SET POINT BUTTON 

ba

This button enables or disables the weather dependent set point
function which is available in space heating operation only.

If the controller is set in permission level 2 or 3 (refer to 

"Field

settings" on page 13

), the weather dependent set point button

will not be operable.

28. INSPECTION/TEST OPERATION BUTTON 

z

This button is used for installation purposes and changing field
settings. Refer to 

"Field settings" on page 13

.

29. PROGRAMMING BUTTON 

<

This multi-purpose button is used to program the controller. The
function of the button depends on the actual status of the
controller or on previous actions carried out by the operator.

30. SCHEDULE TIMER BUTTON 

r

/

p

The main function of this multi-purpose button is to
enable/disable the schedule timer.

The button is also used to program the controller. The function of
the button depends on the actual status of the controller or on
previous actions carried out by the operator.

If the controller is set in permission level 3 (refer to 

"Field

settings" on page 13

), the schedule timer button will not be

operable.

31. TIME ADJUST BUTTON 

pi

 and 

pj

These multi-purpose buttons are used to adjust the clock, to
toggle between temperatures (water outlet temperature of the
indoor unit, outdoor ambient temperature and domestic hot
water temperature) and in schedule timer programming mode.

32. TEMPERATURE ADJUST BUTTONS 

bi

 and 

bj

These multi-purpose buttons are used to adjust the current set
point in normal operation mode or in schedule timer
programming mode. In weather dependent set point mode the
buttons are used to adjust the shift value. Finally, the buttons are
also used to select the weekday while setting the clock.

33. DOMESTIC HOT WATER TEMPERATURE ADJUST BUTTONS

wbi

 and 

wbj

These buttons are used to adjust the current set point of the
domestic hot water temperature.

The buttons are not used when the domestic hot water tank is
not installed.

34. QUIET MODE BUTTON 

s

This button enables or disables quiet mode.

If the controller is set in permission level 2 or 3 (refer to 

"Field

settings" on page 13

), the quiet mode button will not be

operable.

Setting up the controller

After initial installation, the user can set the clock and day of the
week.

The controller is equipped with a schedule timer that enables the
user to schedule operations. Setting the clock and day of the week is
required to be able to use the schedule timer.

Setting the clock

1

Hold down the 

pr

 button for 5 seconds.

The clock read-out and the day of week indicator start flashing.

2

Use the 

pi

 and 

pj

 buttons to adjust the clock.

Each time the 

pi

  or 

pj

  button is pressed, the time will

increase/decrease by 1 minute. Keeping the 

pi

  or 

pj

button pressed will increase/decrease the time by 10 minutes.

3

Use the 

bi

 or 

bj

 button to adjust the day of the week.

Each time the 

bi

  or 

bj

  button is pressed the next or

previous day is displayed.

4

Press the 

<

 button to confirm the current set time and day of the

week.

To leave this procedure without saving, press the 

pr

 button.

If no button is pressed for 5 minutes the clock and day of the
week will return to their previous setting.

Setting the schedule timer

To  set the schedule timer, refer to chapter 

"Programming and

consulting the schedule timer" on page 8

.

Description of the operation modes

Space heating operation (

h

)

In this mode, heating will be activated as required by the water
temperature set point. The set point can be set manually (refer to

"Manual operation" on page 6

) or weather dependent (refer to

"Selecting weather dependent set point operation (only in heating
mode)" on page 7

).

Startup (

d

)

At the start of a heating operation, the pump is not started until a
certain refrigerant heat exchanger temperature is reached. This
guarantees correct startup of the heat pump. During startup, icon

d

 is displayed.

Defrost (

d

)

In space heating operation or heat pump domestic water heating
operation, freezing of the outdoor heat exchanger may occur due to
low outdoor temperature. If this risk occurs, the system goes into
defrost operation. It reverses the cycle and takes heat from the indoor
system to prevent freezing of the outdoor system. After a maximum
of 8 minutes of defrost operation, the system returns to space
heating operation.

Remark that pushing the 

y

  button has no influence on

the domestic water heating. Domestic water heating is only
switched on or off by means of the 

v

 button.

The clock needs to be set manually. Adjust the setting
when switching from summertime to wintertime and vice
versa.

Содержание EKHBHE008BA3V3

Страница 1: ...OPERATION MANUAL EKHBHE008BA3V3 EKHBXE008BA3V3 Indoor unit for air to water heat pump system and options For installation WITH restricted power supply condition 6 kW ...

Страница 2: ...timer by means of the controller maintain the unit and solve operational problems General information Thank you for purchasing this indoor unit The unit is the indoor part of the air to water ERHQ or ERLQ heat pumps These units are designed for wall mounted indoor installation The units can be combined with Daikin fan coil units floor heating applications low temperature radiators Daikin domestic ...

Страница 3: ...and will stop the outdoor unit and the indoor circulation pump when the room temperature is above the thermostat set point Next recommendations only apply to installations with an optional domestic hot water tank Make sure the domestic hot water is only heated up to the domestic hot water temperature you require Start with a low domestic hot water temperature set point e g 45 C and only increase i...

Страница 4: ... unit If during backup heater operation the heating load is higher than the heater capacity the water temperature can not increase In this case refer to Re start at low outdoor ambient temperatures in the installation manual Balance between space heating cooling demand and domestic hot water demand Only if the unit is correctly sized then at some point during space cooling heating operation the un...

Страница 5: ...rogramming the schedule timer 10 INSPECTION REQUIRED k and l These icons indicate that inspection is required on the installation Consult your dealer 11 SET TEMPERATURE DISPLAY 9 The display shows the current space heating cooling set temperature of the installation 12 SETTING Not used For installation purposes only 13 NOT AVAILABLE n This icon is displayed whenever a non installed option is addre...

Страница 6: ...roller is set in permission level 2 or 3 refer to Field settings on page 13 the quiet mode button will not be operable Setting up the controller After initial installation the user can set the clock and day of the week The controller is equipped with a schedule timer that enables the user to schedule operations Setting the clock and day of the week is required to be able to use the schedule timer ...

Страница 7: ...oid overheating space heating is not operable when the outdoor ambient temperature rises above a certain temperature as set through field setting 4 02 refer to Field settings on page 13 Temperature range for cooling 5 C to 22 C 3 Switch on the unit by pushing the y button The operation LED 0 lights up The space cooling temperature set point can only be set manually refer to Manual operation on pag...

Страница 8: ...r disabled p icon not displayed by pressing the pr button To set up the SCHEDULE TIMER refer to chapter Programming and consulting the schedule timer on page 8 What can the schedule timer do The schedule timer allows the programming of 1 Space heating and space cooling refer to Programming space heating or space cooling on page 9 Switch on the desired mode at a scheduled time in combination with a...

Страница 9: ...with the highest action number will be executed You can always alter add or remove the programmed actions later When programming heating actions time and set point cooling actions are added automatically at the same time but with the predefined default cooling set point Conversely when programming cooling actions time and set point heating actions are added automatically at the same time but with ...

Страница 10: ...n to select x to switch cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 10 Use the pi and pj buttons to set the correct action time 11 Repeat steps 8 to 10 to program the other actions of the selected day When all actions have been programmed make sure that the display shows the hig...

Страница 11: ...s Consulting space heating or space cooling is carried out as follows 1 Use the button to select the operation mode cooling or heating you want to consult 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to consult by means of the pi and pj buttons The selected day is blinking 5 Press the butto...

Страница 12: ... 3 are stored but 4 and 5 are deleted Deleting a mode 1 Press the button The actual mode is blinking 2 Use the pi and pj buttons to select the mode you want to delete quiet mode s booster heating m or domestic water heating w The selected mode is blinking 3 Press the and ba button simultaneously for 5 seconds to delete the selected mode Deleting a day of the week cooling or heating mode 1 Use the ...

Страница 13: ...ton to select action number 2 11 Use the pi and pj buttons to set the action time to 4 00 12 Use the ba buttons to select what the unit should do from 4 00 onwards 9 set the tempearature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 13 Press the button for 5 seconds to store the programmed actions You automatically return to step 4 By pressing...

Страница 14: ...d domestic hot water schedule timers are used make sure they are enabled during the period that space heating cooling is disabled Example pattern 0 0 0 0 0 0 0 00 0 0 0 1 1 1 1 0 0 0 00 0 0 0 2 2 2 2 0 0 0 00 0 0 0 3 3 3 3 0 0 0 00 0 0 0 4 4 4 4 0 0 0 00 0 0 0 5 5 5 5 0 0 0 00 0 0 0 6 6 6 6 0 0 0 00 0 0 0 7 7 7 7 0 0 0 00 0 0 0 2 2 2 23 3 3 3 5 5 5 59 9 9 9 Space heating cooling Domestic water hea...

Страница 15: ...mestic hot water tank The disinfection function disinfects the domestic hot water tank by periodically heating the domestic hot water to a specific temperature 2 00 Operation interval day s of the week at which the domestic hot water should be heated 2 01 Status defines whether the disinfection function is turned on 1 or off 0 2 02 Start time time of the day at which the domestic hot water should ...

Страница 16: ... information readout E 00 Readout of the software version example 23 E 01 Readout of the EEPROM version example 23 E 02 Readout of the unit model identification example 11 E 03 Readout of the liquid refrigerant temperature E 04 Readout of the inlet water temperature Space heating cooling always has priority over the disinfection function The disinfection function is only possible when the unit is ...

Страница 17: ...o restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 25 14 25 1 C 03 Installation related setting 04 Installation related setting 5 Installation related settings 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 In...

Страница 18: ...I O PCB 00 Solar priority mode setting 0 0 1 1 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 Installation related setting D Local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Local shift value weather dependent 0 0 1 2 3 4 E Unit information readout 00 Software v...

Страница 19: ...gerant of oil and other parts must be done by a qualified installer in accordance with relevant local and national legislation Units must be treated at a specialized treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative consequences for the environment and human health Please contact the installer or loca...

Страница 20: ...NOTES NOTES ...

Страница 21: ......

Страница 22: ...4PW56302 1 Copyright Daikin ...

Отзывы: