EKHBH/XE008BA

Indoor unit for air to water heat pump system and options

4PW56302-1

Operation manual

8

4.

Domestic water heating (refer to 

"Programming quiet mode,

booster heating or domestic water heating" on page 10

)

Switch the mode on or off at a scheduled time. Five actions can
be programmed per mode. These actions are repeated daily.

What can the schedule timer NOT do?

The schedule timer can not change the operation mode from space
heating to space cooling or vice versa.

How to interpret the programmed actions

To be able to understand the behaviour of your installation when the
schedule timer is enabled, it is important to keep in mind that the
"last" programmed command overruled the "preceding" programmed
command and will remain active until the "next" programmed
command occurs.

Example: imagine the actual time is 17:30 and actions are
programmed at 13:00, 16:00 and 19:00. The "last" programmed
command (16:00) overruled the "previous" programmed command
(13:00) and will remain active until the "next" programmed command
(19:00) occurs.

So in order to know the actual setting, one should consult the last
programmed command. It is clear that the "last" programmed
command may date from the day before. Refer to 

"Consulting

programmed actions" on page 10

.

Programming and consulting the schedule timer

Getting started

Programming the schedule timer is flexible (you can add, remove or
alter programmed actions whenever required) and straightforward
(programming steps are limited to a minimum). However, before
programming the schedule timer, remind:

Familiarise yourself with the icons and the buttons. You will need
them when programming. Refer to 

"Name and function of

buttons and icons" on page 4

.

Fill out the form at the very end of this manual. This form can
help you define the required actions for each day. Keep in mind
that:
-

In the space heating/cooling program, 5 actions can be 
programmed per weekday. The same actions are repeated 
on a weekly basis.

-

In the domestic water heating, booster heater and quiet 
mode program, 5 actions can be programmed per mode. The 
same actions are repeated on a daily basis.

Take your time to enter all data accurately.

Try to program the actions in a chronological way: start with
action 1 for the first action and end with the highest number for
the last action. This is not a requirement but will simplify the
interpretation of the program later.

If 2 or more actions are programmed for the same day and at the
same time, only the action with the highest action number will be
executed.

You can always alter, add or remove the programmed actions
later.

When programming heating actions (time and set point), cooling
actions are added automatically at the same time but with the
predefined default cooling set point. Conversely, when
programming cooling actions (time and set point), heating
actions are added automatically at the same time but with the
default heating set point.

The set points of these automatically added actions can be
adjusted by programming the corresponding mode. This means
that after programming heating, you should also program the
corresponding cooling set points and vice versa.

The programmed actions are not stored according to
their timing but according to the time of programming.
This means that the action that was programmed first
gets action number 1, even though it is executed after
other programmed action numbers.

When the schedule timer switches space heating or
space cooling 

x

, the controller will also be

switched off. Note that this has no influence on
domestic water heating.

During schedule timer operation, someone may have
altered the actual settings manually (in other words, the
"last" command was overruled manually). The icon 

p

,

indicating the schedule timer operation, may still be
displayed, giving the impression that the "last" command
settings are still active. The "next" programmed command
will overrule the altered settings and return to the original
program.

Due to the fact that the schedule timer cannot switch
between operation modes (heating or cooling) and the fact
that each programmed action implies a heating set point
and a cooling set point, the following situations may occur:

when the schedule timer is active in heating mode,
and the mode is changed manually to cooling (by
means of the 

=

  button), the operation mode will

from then on remain cooling and program actions will
follow the corresponding cooling set points. Returning
to heating mode needs to be carried out manually (by
means of the 

=

 button).

when the schedule timer is active in cooling mode,
and the mode is changed manually to heating (by
means of the 

=

  button), the operation mode will

from then on remain heating and program actions will
follow the corresponding heating set points. Returning
to cooling mode needs to be carried out manually (by
means of the 

=

 button).

The above proves the importance of programming both
cooling and heating set points for each action. If you do not
program these set points, the predefined default values will
be used.

Before you start any programming, read attentively the
warnings mentioned in the paragraph 

"Introduction" on

page 2

 to understand unit operation.

Содержание EKHBHE008BA3V3

Страница 1: ...OPERATION MANUAL EKHBHE008BA3V3 EKHBXE008BA3V3 Indoor unit for air to water heat pump system and options For installation WITH restricted power supply condition 6 kW ...

Страница 2: ...timer by means of the controller maintain the unit and solve operational problems General information Thank you for purchasing this indoor unit The unit is the indoor part of the air to water ERHQ or ERLQ heat pumps These units are designed for wall mounted indoor installation The units can be combined with Daikin fan coil units floor heating applications low temperature radiators Daikin domestic ...

Страница 3: ...and will stop the outdoor unit and the indoor circulation pump when the room temperature is above the thermostat set point Next recommendations only apply to installations with an optional domestic hot water tank Make sure the domestic hot water is only heated up to the domestic hot water temperature you require Start with a low domestic hot water temperature set point e g 45 C and only increase i...

Страница 4: ... unit If during backup heater operation the heating load is higher than the heater capacity the water temperature can not increase In this case refer to Re start at low outdoor ambient temperatures in the installation manual Balance between space heating cooling demand and domestic hot water demand Only if the unit is correctly sized then at some point during space cooling heating operation the un...

Страница 5: ...rogramming the schedule timer 10 INSPECTION REQUIRED k and l These icons indicate that inspection is required on the installation Consult your dealer 11 SET TEMPERATURE DISPLAY 9 The display shows the current space heating cooling set temperature of the installation 12 SETTING Not used For installation purposes only 13 NOT AVAILABLE n This icon is displayed whenever a non installed option is addre...

Страница 6: ...roller is set in permission level 2 or 3 refer to Field settings on page 13 the quiet mode button will not be operable Setting up the controller After initial installation the user can set the clock and day of the week The controller is equipped with a schedule timer that enables the user to schedule operations Setting the clock and day of the week is required to be able to use the schedule timer ...

Страница 7: ...oid overheating space heating is not operable when the outdoor ambient temperature rises above a certain temperature as set through field setting 4 02 refer to Field settings on page 13 Temperature range for cooling 5 C to 22 C 3 Switch on the unit by pushing the y button The operation LED 0 lights up The space cooling temperature set point can only be set manually refer to Manual operation on pag...

Страница 8: ...r disabled p icon not displayed by pressing the pr button To set up the SCHEDULE TIMER refer to chapter Programming and consulting the schedule timer on page 8 What can the schedule timer do The schedule timer allows the programming of 1 Space heating and space cooling refer to Programming space heating or space cooling on page 9 Switch on the desired mode at a scheduled time in combination with a...

Страница 9: ...with the highest action number will be executed You can always alter add or remove the programmed actions later When programming heating actions time and set point cooling actions are added automatically at the same time but with the predefined default cooling set point Conversely when programming cooling actions time and set point heating actions are added automatically at the same time but with ...

Страница 10: ...n to select x to switch cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 10 Use the pi and pj buttons to set the correct action time 11 Repeat steps 8 to 10 to program the other actions of the selected day When all actions have been programmed make sure that the display shows the hig...

Страница 11: ...s Consulting space heating or space cooling is carried out as follows 1 Use the button to select the operation mode cooling or heating you want to consult 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to consult by means of the pi and pj buttons The selected day is blinking 5 Press the butto...

Страница 12: ... 3 are stored but 4 and 5 are deleted Deleting a mode 1 Press the button The actual mode is blinking 2 Use the pi and pj buttons to select the mode you want to delete quiet mode s booster heating m or domestic water heating w The selected mode is blinking 3 Press the and ba button simultaneously for 5 seconds to delete the selected mode Deleting a day of the week cooling or heating mode 1 Use the ...

Страница 13: ...ton to select action number 2 11 Use the pi and pj buttons to set the action time to 4 00 12 Use the ba buttons to select what the unit should do from 4 00 onwards 9 set the tempearature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 13 Press the button for 5 seconds to store the programmed actions You automatically return to step 4 By pressing...

Страница 14: ...d domestic hot water schedule timers are used make sure they are enabled during the period that space heating cooling is disabled Example pattern 0 0 0 0 0 0 0 00 0 0 0 1 1 1 1 0 0 0 00 0 0 0 2 2 2 2 0 0 0 00 0 0 0 3 3 3 3 0 0 0 00 0 0 0 4 4 4 4 0 0 0 00 0 0 0 5 5 5 5 0 0 0 00 0 0 0 6 6 6 6 0 0 0 00 0 0 0 7 7 7 7 0 0 0 00 0 0 0 2 2 2 23 3 3 3 5 5 5 59 9 9 9 Space heating cooling Domestic water hea...

Страница 15: ...mestic hot water tank The disinfection function disinfects the domestic hot water tank by periodically heating the domestic hot water to a specific temperature 2 00 Operation interval day s of the week at which the domestic hot water should be heated 2 01 Status defines whether the disinfection function is turned on 1 or off 0 2 02 Start time time of the day at which the domestic hot water should ...

Страница 16: ... information readout E 00 Readout of the software version example 23 E 01 Readout of the EEPROM version example 23 E 02 Readout of the unit model identification example 11 E 03 Readout of the liquid refrigerant temperature E 04 Readout of the inlet water temperature Space heating cooling always has priority over the disinfection function The disinfection function is only possible when the unit is ...

Страница 17: ...o restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 25 14 25 1 C 03 Installation related setting 04 Installation related setting 5 Installation related settings 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 In...

Страница 18: ...I O PCB 00 Solar priority mode setting 0 0 1 1 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 Installation related setting D Local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Local shift value weather dependent 0 0 1 2 3 4 E Unit information readout 00 Software v...

Страница 19: ...gerant of oil and other parts must be done by a qualified installer in accordance with relevant local and national legislation Units must be treated at a specialized treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative consequences for the environment and human health Please contact the installer or loca...

Страница 20: ...NOTES NOTES ...

Страница 21: ......

Страница 22: ...4PW56302 1 Copyright Daikin ...

Отзывы: