background image

 

Operation manual

 

1

 

EKHBH/XE008BA

 

Indoor unit for air to water heat pump system and options

 

4PW56304-1

 

C

 

ONTENTS

 

Page

 

Introduction ..................................................................................... 1

 

This manual ............................................................................................... 1
General information ................................................................................... 1
Safety considerations ................................................................................ 2

 

Operating the unit ........................................................................... 2

 

Introduction ....................................................................................... 2

Operating the digital controller .......................................................... 3

 

Features and functions .............................................................................. 3

Basic controller functions ...................................................................... 3
Clock function........................................................................................ 3
Schedule timer function......................................................................... 3

Name and function of buttons and icons ................................................... 3
Setting up the controller............................................................................. 5

Setting the clock .................................................................................... 5
Setting the schedule timer..................................................................... 5

Description of the operation modes ........................................................... 5

Space heating operation (

 

h

 

) ................................................................. 5

Space cooling operation (

 

c

 

) ................................................................. 5

Domestic water heating operation (

 

w

 

) ................................................. 5

Quiet mode operation (

 

s

 

).................................................................... 5

Controller operations ................................................................................. 6

Manual operation................................................................................... 6
Schedule timer operation ...................................................................... 7

Programming and consulting the schedule timer....................................... 8

Getting started....................................................................................... 8
Programming......................................................................................... 8
Consulting programmed actions.......................................................... 10
Tips and tricks ..................................................................................... 10

 

Field settings ................................................................................... 11

 

Procedure ................................................................................................ 11
Detailed description ................................................................................. 11
Field settings table................................................................................... 14

 

Maintenance .................................................................................. 16

 

Important information regarding the refrigerant used .............................. 16
Maintenance activities ............................................................................. 16
Standstill .................................................................................................. 16

 

Troubleshooting ............................................................................ 16

Disposal requirements ................................................................. 16

 

The English text is the original instruction. Other languages are
translations of the original instructions.

This appliance is not intended for use by persons, including children,
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with
the appliance.

 

I

 

NTRODUCTION

 

This manual

 

This manual describes how to start up and switch off the unit, set
parameters and configure the schedule timer by means of the
controller, maintain the unit and solve operational problems.

 

General information

 

Thank you for purchasing this indoor unit.

The unit is the indoor part of the air to water ERHQ or ERLQ heat
pumps. These units are designed for wall mounted indoor installation.
The units can be combined with Daikin fan coil units, floor heating
applications, low temperature radiators, Daikin domestic water
heating applications and Daikin solar kit for domestic hot water
applications.

 

Heating/cooling units and heating only units

 

The unit range consists of two main versions: a heating/cooling
(EKHBX) version and a heating only (EKHBH) version.

Both versions are delivered with an integrated backup heater for
additional heating capacity during cold outdoor temperatures. The
backup heater also serves as a backup in case of malfunctioning of
the outdoor unit.

 

Domestic hot water tank (option)

 

An optional EKHW* domestic hot water tank with integrated 3 kW
electrical booster heater can be connected to the indoor unit. The
domestic hot water tank is available in three sizes: 150, 200 and
300 litre.

 

Solar kit for domestic hot water tank (option)

 

For information concerning the EKSOLHW solar kit, refer to the
installation manual of that kit.

 

Remote thermostat kit (option)

 

An optional room thermostat EKRTW, EKRTWA, or EKRTR can be
connected to the indoor unit. Refer to the operation manual of the
room thermostat for more information.

 

EKHBHE008BA***
EKHBXE008BA***

 

Indoor unit for air to water heat pump system

and options

 

Operation manual

 

READ THIS MANUAL ATTENTIVELY BEFORE STARTING
UP THE UNIT. DO NOT THROW IT AWAY. KEEP IT IN
YOUR FILES FOR FUTURE REFERENCE.

 

Before operating the unit, make sure the installation has
been carried out correctly by a professional Daikin dealer.

If you feel unsure about operation, contact your Daikin
dealer for advice and information.

 

Indoor unit model

Backup heater capacity

Backup heater 

nominal voltage

EKHB*E008BA3V3

 

3 kW

1x 230 V

 

The heat pump unit is preset to a restricted power supply
condition mode. The information in this manual is only valid
in case the power supply condition is not restricted. Refer
to the chapter 

"Field settings" on page 11

  on how to

disable the restricted power supply condition mode [D-02].

Содержание EKHBHE008BA

Страница 1: ...OPERATION MANUAL EKHBHE008BA EKHBXE008BA Indoor unit for air to water heat pump system and options For installation WITHOUT restricted power supply condition 6 kW...

Страница 2: ...he air to water ERHQ or ERLQ heat pumps These units are designed for wall mounted indoor installation The units can be combined with Daikin fan coil units floor heating applications low temperature ra...

Страница 3: ...ostat connected to the indoor unit This will prevent excessive space heating and will stop the outdoor unit and the indoor circulation pump when the room temperature is above the thermostat set point...

Страница 4: ...pace heating h space cooling c domestic water heating w or quiet mode s Within limits different modes can be combined e g space heating and domestic water heating The corresponding mode icons will be...

Страница 5: ...button allows manual switching between heating or cooling mode provided the unit is not a heating only unit When the unit is connected with an external room thermostat this button is not operable and...

Страница 6: ...on the system returns to space heating operation Space cooling operation c In this mode cooling will be activated as required by the water temperature set point Domestic water heating operation w In t...

Страница 7: ...on 1 Press v for 5 seconds to activate powerful domestic water heating operation Icons w and m start flashing Powerful domestic water heating is deactivated automatically when the set point for the do...

Страница 8: ...rammed at 13 00 16 00 and 19 00 The last programmed command 16 00 overruled the previous programmed command 13 00 and will remain active until the next programmed command 19 00 occurs So in order to k...

Страница 9: ...int Conversely when programming cooling actions time and set point heating actions are added automatically at the same time but with the default heating set point The set points of these automatically...

Страница 10: ...nds to store the programmed actions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted You automatically return to step 6 By pressing the p...

Страница 11: ...ram it is possible to copy all programmed actions of a specific day to the next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day proceed as follows 1 Press th...

Страница 12: ...lected the actual permission level either level 2 or level 3 is determined by the field setting 0 00 1 Weather dependent set point heating operation only The weather dependent set point field settings...

Страница 13: ...t lower limit minimum leaving water temperature for heating operation 9 02 Cooling set point upper limit maximum leaving water temperature for cooling operation 9 03 Cooling set point lower limit mini...

Страница 14: ...on readout E 00 Readout of the software version example 23 E 01 Readout of the EEPROM version example 23 E 02 Readout of the unit model identification example 11 E 03 Readout of the liquid refrigerant...

Страница 15: ...restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 25 14 25 1 C 03 Installation related settin...

Страница 16: ...O PCB 00 Solar priority mode setting 0 0 1 1 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 Installation related setting D Local shift value weathe...

Страница 17: ...cts shall not be mixed with unsorted household waste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qua...

Страница 18: ...NOTES NOTES...

Страница 19: ......

Страница 20: ...4PW56304 1 Copyright Daikin...

Отзывы: