EKHBH/X008BA

 

Indoor unit for air to water heat pump system and options

 

4PW54184-1

 

Operation manual

 

4

 

7.

 

SCHEDULE TIMER ICON 

 

p

 

This icon indicates that the schedule timer is enabled.

 

8.

 

ACTION ICONS 

 

q

 

These icons indicate the programming actions for each day of
the schedule timer.

 

9.

 

OFF ICON 

 

x

 

This icon indicates that the OFF action is selected when
programming the schedule timer.

 

10.

 

INSPECTION REQUIRED 

 

k

 

 and 

 

l

 

These icons indicate that inspection is required on the
installation. Consult your dealer.

 

11.

 

SET TEMPERATURE DISPLAY 

 

9

 

The display shows the current space heating/cooling set
temperature of the installation.

 

12.

 

SETTING 

 

$

 

Not used. For installation purposes only.

 

13.

 

NOT AVAILABLE 

 

n

 

This icon is displayed whenever a non-installed option is
addressed or a function is not available.

 

14.

 

DEFROST/STARTUP MODE ICON 

 

d

 

This icon indicates that the defrost/startup mode is active.

 

15.

 

COMPRESSOR ICON 

 

ç

 

This icon indicates that the compressor in the outdoor unit of the
installation is active.

16. BACKUP HEATER STEP ONE 

(

 OR STEP TWO 

§

These icons indicate that the backup heater is operating on low
capacity (

(

) or on high capacity (

§

). The backup heater

provides extra heating capacity in case of low ambient outdoor
temperature (high heating load).

17. BOOSTER HEATER ICON 

m

This icon indicates that the booster heater is active. The booster
heater provides auxiliary heating for the domestic hot water
tank.

The booster heater is located in the domestic hot water tank.

The icon is not used when the domestic hot water tank is not
installed.

18. PUMP ICON 

é

This icon indicates that the circulation pump is active.

19. OUTDOOR TEMPERATURE DISPLAY 

u

When this icon is flashing, the outdoor ambient temperature is
displayed.

20. WEATHER DEPENDENT SET POINT ICON 

a

This icon indicates that the controller will adapt the temperature
set point automatically, based on the outdoor ambient
temperature.

21. TEMPERATURE ICON 

b

This icon is displayed when the water outlet temperature of the
indoor unit, the outdoor ambient temperature and the domestic
hot water tank temperature are shown.

The icon is also displayed when the temperature set point is set
in schedule timer programming mode.

22. TEST OPERATION ICON 

t

This icon indicates that the unit runs in test mode.

23. FIELD SET CODE 

;

This code represents the code from the field set list. Refer to the

"Field settings table" on page 13

.

24. ERROR CODE 

:

This code refers to the error code list and is for service purposes
only. Refer to the error code list in the installation manual.

25. SPACE HEATING/COOLING BUTTON 

=

This button allows manual switching between heating or cooling
mode (provided the unit is not a heating only unit).

When the unit is connected with an external room thermostat,
this button is not operable and the icon 

e

 is shown.

26. DOMESTIC WATER HEATING BUTTON 

v

This button enables or disables heating of the domestic water.

This button is not used when the domestic hot water tank is not
installed.

27. WEATHER DEPENDENT SET POINT BUTTON 

ba

This button enables or disables the weather dependent set point
function which is available in space heating operation only.

If the controller is set in permission level 2 or 3 (refer to 

"Field

settings" on page 10

), the weather dependent set point button

will not be operable.

28. INSPECTION/TEST OPERATION BUTTON 

z

This button is used for installation purposes and changing field
settings. Refer to 

"Field settings" on page 10

.

29. PROGRAMMING BUTTON 

<

This multi-purpose button is used to program the controller. The
function of the button depends on the actual status of the
controller or on previous actions carried out by the operator.

30. SCHEDULE TIMER BUTTON 

r

/

p

The main function of this multi-purpose button is to
enable/disable the schedule timer.

The button is also used to program the controller. The function of
the button depends on the actual status of the controller or on
previous actions carried out by the operator.

If the controller is set in permission level 3 (refer to 

"Field

settings" on page 10

), the schedule timer button will not be

operable.

31. TIME ADJUST BUTTON 

pi

 and 

pj

These multi-purpose buttons are used to adjust the clock, to
toggle between temperatures (water outlet temperature of the
indoor unit, outdoor ambient temperature and domestic hot
water temperature) and in schedule timer programming mode.

32. TEMPERATURE ADJUST BUTTONS 

bi

 and 

bj

These multi-purpose buttons are used to adjust the current set
point in normal operation mode or in schedule timer
programming mode. In weather dependent set point mode the
buttons are used to adjust the shift value. Finally, the buttons are
also used to select the weekday while setting the clock.

33. DOMESTIC HOT WATER TEMPERATURE ADJUST BUTTONS

wbi

 and 

wbj

These buttons are used to adjust the current set point of the
domestic hot water temperature.

The buttons are not used when the domestic hot water tank is
not installed.

34. QUIET MODE BUTTON 

s

This button enables or disables quiet mode.

If the controller is set in permission level 2 or 3 (refer to 

"Field

settings" on page 10

), the quiet mode button will not be

operable.

Remark that pushing the 

y

  button has no influence on

the domestic water heating. Domestic water heating is only
switched on or off by means of the 

v

 button.

Содержание EKHBH008BA

Страница 1: ...OPERATION MANUAL EKHBH008BA EKHBX008BA Indoor unit for air to water heat pump system and options...

Страница 2: ...water ERHQ or ERLQ heat pumps These units are designed for wall mounted indoor installation The units can be combined with Daikin fan coil units floor heating applications low temperature radiators D...

Страница 3: ...stat connected to the indoor unit This will prevent excessive space heating and will stop the outdoor unit and the indoor circulation pump when the room temperature is above the thermostat set point N...

Страница 4: ...eration mode s space heating h space cooling c domestic water heating w or quiet mode s Within limits different modes can be combined e g space heating and domestic water heating The corresponding mod...

Страница 5: ...E HEATING COOLING BUTTON This button allows manual switching between heating or cooling mode provided the unit is not a heating only unit When the unit is connected with an external room thermostat th...

Страница 6: ...ater provides auxiliary heating for the domestic hot water tank Powerful domestic water heating operation In the case of urgent need of domestic hot water the domestic hot water temperature set point...

Страница 7: ...R refer to chapter Programming and consulting the schedule timer on page 7 What can the schedule timer do The schedule timer allows the programming of 1 Space heating and space cooling refer to Progra...

Страница 8: ...in a chronological way start with action 1 for the first action and end with the highest number for the last action This is not a requirement but will simplify the interpretation of the program later...

Страница 9: ...to select x to switch cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 10 Use the pi...

Страница 10: ...you want to consult 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to consult by means of the...

Страница 11: ...ode cooling or heating you want to delete 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to d...

Страница 12: ...tallations with a domestic hot water tank The disinfection function disinfects the domestic hot water tank by periodically heating the domestic hot water to a specific temperature 2 00 Operation inter...

Страница 13: ...Local shift value weather dependent Local shift value weather dependent The local shift value weather dependent field setting is only relevant in case weather dependent set point see field setting 1 W...

Страница 14: ...restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 25 14 25 1 C 03 Installation related setting...

Страница 15: ...related setting D Local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Local shift value weather dependent 0 0 1 2 3...

Страница 16: ...ed household waste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance wit...

Страница 17: ......

Страница 18: ...4PW54184 1 Copyright Daikin...

Отзывы: