10

Tips and tricks

Programming the next day(s)

After confirming the programmed actions of a specific day (i.e. after
pressing the 

<

 button for 5 seconds), press the 

pr

 button once. You

can now select another day by using the 

pi

 and 

pj

 buttons

and restart consulting and programming.

Copying programmed actions to next day

In heating/cooling program it is possible to copy all programmed
actions of a specific day to the next day (e.g. copy all programmed
actions from "

1

" to "

2

").

To copy programmed actions to the next day, proceed as follows:

1

Press the 

<

 button.

The actual mode is blinking.

2

Use the 

pi

 and 

pj

 buttons to select the mode you want

to program.

The selected mode is blinking.

You can leave programming by pressing the 

pr

 button.

3

Press the 

<

 button to confirm the selected mode.

The actual day is blinking.

4

Select the day you would like to copy to the next day by means
of the 

pi

 and 

pj

 buttons.

The selected day is blinking.

You can return to step 

2

 by pressing the 

pr

 button.

5

Press the 

<

 and 

pr

 buttons simultaneously for 5 seconds.

After 5 seconds the display will show the next day (e.g. "

2

" if

"

1

" was selected first). This indicates that the day has been

copied.

You can return to step 

2

 by pressing the 

pr

 button.

Deleting one or more programmed actions

Deleting one or more programmed actions is done at the same time
as storing the programmed actions.

When all actions for one day have been programmed, make sure that
the display shows the highest action number you would like to save.
By pressing the 

<

 button for 5 seconds, you store all actions except

those with a higher action number than the one that is displayed.

E.g. when the 

<

  button is pressed when action number 3 is

displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted.

Deleting a mode

1

Press the 

<

 button.

The actual mode is blinking.

2

Use the 

pi

 and 

pj

 buttons to select the mode you want

to delete (quiet mode 

s

, booster heating 

m

 or domestic water

heating 

w

).

The selected mode is blinking.

3

Press the 

<

  and 

ba

  button simultaneously for 5 seconds to

delete the selected mode.

Deleting a day of the week (cooling or heating mode)

1

Use the 

=

  button to select the operation mode (cooling or

heating) you want to delete.

2

Press the 

<

 button.

The actual mode is blinking.

3

Press the 

<

 button to confirm the selected mode.

The actual day is blinking.

4

Select the day you would like to delete by means of the 

pi

and 

pj

 buttons.

The selected day is blinking.

5

Press the 

<

  and 

ba

  button simultaneously for 5 seconds to

delete the selected day.

F

IELD

 

SETTINGS

The indoor unit shall be configured by the installer to match the
installation environment (outdoor climate, installed options, etc.) and
user demand. However, the field settings mentioned in 

"Field settings

table" on page 13

 can be modified to customer preferences. Thereto,

a number of so called field settings are available. These field settings
are accessible and programmable through the user interface on the
indoor unit.

Each field setting is assigned a 3-digit number or code, for example
[1-03], which is indicated on the user interface display. The first digit
[1] indicates the 'first code' or field setting group. The second and
third digit [03] together indicate the 'second code'.

A list of all field settings and default values is given under 

"Field

settings table" on page 13

.  In this same list, we provided for 2

columns to register the date and value of altered field settings at
variance with the default value.

A detailed description of each field setting is given under 

"Detailed

description" on page 11

.

Procedure

To change one or more field settings, proceed as follows.

1

Press the 

z

 button for a minimum of 5 seconds to enter FIELD

SET MODE.
The 

$

 icon (3) will be displayed. The current selected field

setting code is indicated 

;

 (2), with the set value displayed to

the right 

-

 (1).

2

Press the 

bgi

  button to select the appropriate field

setting first code.

3

Press the 

bgj

  button to select the appropriate field

setting second code.

4

Press the 

pfi

  button and 

pfj

  button to change

the set value of the select field setting.

5

Save the new value by pressing the 

pr

 button.

NOTE

The default values mentioned in 

"Field settings table"

on page 13

  are the values from factory. The actual

initial values shall be selected according to your
application. These values shall be confirmed by your
installer.

CAUTION

The field settings [2] depends on the relevant local and
national regulations.

The field settings [9] depends on the application.

Before changing these settings, the new values shall be
confirmed by the installer and/or shall be according to the
local and national regulations.

2

3

1

Содержание EKHBH008BA

Страница 1: ...OPERATION MANUAL EKHBH008BA EKHBX008BA Indoor unit for air to water heat pump system and options...

Страница 2: ...water ERHQ or ERLQ heat pumps These units are designed for wall mounted indoor installation The units can be combined with Daikin fan coil units floor heating applications low temperature radiators D...

Страница 3: ...stat connected to the indoor unit This will prevent excessive space heating and will stop the outdoor unit and the indoor circulation pump when the room temperature is above the thermostat set point N...

Страница 4: ...eration mode s space heating h space cooling c domestic water heating w or quiet mode s Within limits different modes can be combined e g space heating and domestic water heating The corresponding mod...

Страница 5: ...E HEATING COOLING BUTTON This button allows manual switching between heating or cooling mode provided the unit is not a heating only unit When the unit is connected with an external room thermostat th...

Страница 6: ...ater provides auxiliary heating for the domestic hot water tank Powerful domestic water heating operation In the case of urgent need of domestic hot water the domestic hot water temperature set point...

Страница 7: ...R refer to chapter Programming and consulting the schedule timer on page 7 What can the schedule timer do The schedule timer allows the programming of 1 Space heating and space cooling refer to Progra...

Страница 8: ...in a chronological way start with action 1 for the first action and end with the highest number for the last action This is not a requirement but will simplify the interpretation of the program later...

Страница 9: ...to select x to switch cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 10 Use the pi...

Страница 10: ...you want to consult 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to consult by means of the...

Страница 11: ...ode cooling or heating you want to delete 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to d...

Страница 12: ...tallations with a domestic hot water tank The disinfection function disinfects the domestic hot water tank by periodically heating the domestic hot water to a specific temperature 2 00 Operation inter...

Страница 13: ...Local shift value weather dependent Local shift value weather dependent The local shift value weather dependent field setting is only relevant in case weather dependent set point see field setting 1 W...

Страница 14: ...restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 25 14 25 1 C 03 Installation related setting...

Страница 15: ...related setting D Local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Local shift value weather dependent 0 0 1 2 3...

Страница 16: ...ed household waste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance wit...

Страница 17: ......

Страница 18: ...4PW54184 1 Copyright Daikin...