manualshive.com logo in svg
background image

3 Preparation

Installation manual

3

EK2CB07CAV3
Daikin Altherma low temperature monobloc option box
4P405546­1 – 2015.03

3

Preparation

3.1

Preparing installation site

3.1.1

Installation site requirements of the
option box

▪ Mind the measurement guidelines:

Maximum distance between the option box and
control box EKCB07CAV3

3 m

▪ Mind the following spacing installation guidelines:

100

50

50

600

50

50

(mm)

▪ The option box is designed to be wall­mounted in indoor locations

only. Make sure the installation surface is a flat and vertical non­
combustible wall.

▪ The  option  box  is  designed  to  operate  in  ambient  temperatures

ranging from 5~35°C.

3.2

Preparing electrical wiring

3.2.1

Overview of electrical connections for
external and internal actuators

Item

Description

Wires

Maximum

running

current

Power supply

1

Power supply for option
box

2+GND

(a)

Interconnection cable

2

Interconnection cable
to control box

3 (max 3 m)

(b)

Optional equipment

3

Remote indoor sensor

2

(b)

Field­supplied components

4

Electric meter

2 (per meter)

(b)

5

Power consumption
digital inputs

2 (per input
signal)

(b)

6

Alarm output

2

(b)

7

Space cooling/heating
ON/OFF output

2

(b)

8

Changeover to external
heat source

2

(b)

(a)

Cable section 2.5 mm².

(b)

Minimum cable section 0.75 mm².

NOTICE

More  technical  specifications  of  the  different  connections
are indicated on the inside of the option box.

4

Installation

4.1

Opening the units

4.1.1

To open the option box

1

1

2

WARNING

The  screws  are  delivered  with  toothed  lock  washers.
ALWAYS use toothed lock washers, also when the screws
need  to  be  replaced.  Failure  to  follow  this  warning  may
result in electric shock.

INFORMATION

Do NOT remove the plugs from the front plate of the option
box.

4.2

Mounting the option box

4.2.1

To install the option box

1

Remove the front plate.

2

Hold the back plate against the wall and mark the fixation points
(2 on the top and 2 at the bottom).

NOTICE

Make sure that the marks (2 by 2) are completely level and
that their dimensions correspond to the figure below.

318 mm

310 mm

3

Drill 4 holes and install 4 plugs (suitable for M5).

4

Put  the  screws  in  the  top  plugs  and  hang  the  box  on  the
screws.

5

Put the screws in the bottom plugs.

6

Fix the 4 screws firmly.

Содержание EK2CB07CAV3

Страница 1: ...Installation manual Daikin Altherma low temperature monobloc option box English Installation manual Daikin Altherma low temperature monobloc option box EK2CB07CAV3 ...

Страница 2: ...umentation set This document is part of a documentation set The complete set consists of Document Contains Format General safety precautions Safety instructions that you must read before installing Paper in the box of the outdoor unit Outdoor unit installation manual Installation instructions Paper in the box of the outdoor unit Control box installation manual Installation instructions Paper in th...

Страница 3: ...ctric meter 2 per meter b 5 Power consumption digital inputs 2 per input signal b 6 Alarm output 2 b 7 Space cooling heating ON OFF output 2 b 8 Changeover to external heat source 2 b a Cable section 2 5 mm b Minimum cable section 0 75 mm NOTICE More technical specifications of the different connections are indicated on the inside of the option box 4 Installation 4 1 Opening the units 4 1 1 To ope...

Страница 4: ...connect the option box power supply 1 Connect option box terminal X1M to control box terminal X1M X2M X8M A4P X2M X8M X1M A4P 3 2 1 X1M 3 2 1 1 GND 2 L 3 N 2 Fix the cable with cable ties to the cable tie mountings to ensure strain relief and to make sure that it does NOT come in contact with sharp edges CAUTION Do NOT push or place redundant cable length in the unit 4 3 4 To connect the interconn...

Страница 5: ...to the appropriate terminals as shown in the illustration below X2M X8M X1M A4P 15 13 2 Fix the cable with cable ties to the cable tie mountings 4 3 8 To connect the space cooling heating ON OFF output 1 Connect the space cooling heating ON OFF output cable to the appropriate terminals as shown in the illustration below X8M X1M 1 2 2 Fix the cable with cable ties to the cable tie mountings 4 3 9 T...