EHBH/X04+08+16CA + EHVH/XEHVH/X08+16S18+26CA
Daikin Altherma - Low Temperature Split
4P313773-1 – 2012.05
Operation manual
6
4 Energy saving tips
3.7
Installer settings: Tables to be filled in by
installer
3.7.1 Quick
wizard
3.7.2 Space heating/cooling control
3.7.3 Domestic hot water control [A.4]
3.7.4 Contact/helpdesk number [6.3.2]
4
Energy saving tips
Tips about room temperature
Q
Make sure the desired room temperature is never too high (in
heating mode) or too low (in cooling mode), but always
according to your actual needs. Each saved degree can save up
to 6% of heating/cooling costs.
Q
Do NOT increase the desired room temperature to speed up
space heating. The space will NOT heat up faster.
Q
When your system layout contains slow heat emitters (example:
under floor heating), avoid large fluctuation of the desired room
temperature and do NOT let the room temperature drop too low.
It will take more time and energy to heat up the room again.
Q
Use a weekly schedule for your normal space heating or cooling
needs. If necessary, you can easily deviate from the schedule:
Q
For shorter periods: You can overrule the scheduled room
temperature. Example: When you have a party, or when
you are leaving for a couple of hours.
Q
For longer periods: You can use the holiday mode.
Example: When you stay at home during your holiday, or
when you go away during your holiday.
Setting
Default
Fill in…
Backup heater configuration (only for unified backup heater)
[A.2.1.5]
BUH type
1 (1P,(1/2))
Preferential kWh rate power supply [A.2.1.6]
Preferential kWh rate
0 (LWT
control)
Space heating/cooling settings [A.2.1]
Unit control method
0 (In room)
User interface location
1 (1 LWT
zone)
Number of LWT zones
1 (1 LWT
zone)
Pump operation mode
1 (Sample)
Domestic hot water settings [A.2.2]
DHW operation
Depends on
model
DHW tank heater
Depends on
model
DHW pump
0 (No)
Thermostats [A.2.2]
Contact type main
2 (Thermo
ON/OFF)
Contact type add.
2 (Thermo
ON/OFF)
External sensor
0 (No)
Digital I/O PCB [A.2.2.6]
Ext. backup heat src
0 (No)
Solar kit
0 (No)
Alarm output
0 (Normally
open)
Bottom plate heater
0 (No)
Demand PCB [A.2.2.7]
Demand PCB
0 (No)
Energy metering [A.2.2]
External kWh meter
0 (No)
External kWh meter
0 (No)
Capacities (energy metering) [A.2.3]
Booster heater
0 kW
BUH: step 1
Depends on
model
BUH: step 2
Depends on
model
Bottom plate heater
0 W
Setting
Default
Fill in…
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode
0 (Absolute)
Set weather-dependent heating
25/40/15/–10
Set weather-dependent cooling
18/22/35/20
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode
0 (Absolute)
Set weather-dependent heating
25/40/15/–10
Set weather-dependent cooling
18/22/35/20
Leaving water temperature: Delta T emitter [A.3.1.3]
Heating
5°C
Cooling
5°C
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT
0 (No)
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type
1 (Slow)
Setting
Default
Fill in…
Setpoint mode
0 (Reheat only)
Setpoint readout type
0
(Temperature)
Maximum setpoint
Depends on
model
Setting
Default
Fill in…
Contact/helpdesk number
—
4P313773-1_offset.book Page 6 Monday, June 4, 2012 7:18 AM