7 Installation
Installer reference guide
31
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351748-1D – 2016.02
X1M
N
L3
L2
L1
X2M
30
X6YB
X6Y X6YA
31
X5M
a
X19A
X1A
Legend: see illustration below.
In case of preferential kWh rate power supply
Connect X6Y to X6YB.
X1M
N
L3
L2
L1
X2M
29
34
X6YB
X6YA
X6Y
X5M
a
X19A
X1A
S1S
L
N
b
c
3 4
30 31
a
Main power supply
b
Normal kWh rate power supply
c
Preferential power supply contact
2
Fix the cable with cable ties to the cable tie mountings.
INFORMATION
In case of preferential kWh rate power supply, connect
X6Y to X6YB. The necessity of separate normal kWh rate
power supply to indoor unit (b) X2M30/31 depends on the
type of preferential kWh rate power supply.
Separate connection to the indoor unit is required:
▪ if preferential kWh rate power supply is interrupted
when active, OR
▪ if no power consumption of the indoor unit is allowed at
the preferential kWh rate power supply when active.
7.6.7
To connect the remote outdoor sensor
The remote outdoor sensor (delivered as accessory) measures the
outdoor ambient temperature.
INFORMATION
If the desired leaving water temperature is weather
dependent, the full time outdoor temperature measurement
is important.
1
Connect the external temperature sensor cable to the indoor
unit.
X2M
X5M
11
10
12
2
Fix the cable with cable ties to the cable tie mountings.
3
Install the remote outdoor sensor outside as described in the
installation manual of the sensor (delivered as accessory).
7.6.8
To connect the user interface
▪ If you use 1 user interface, you can install it at the indoor unit (for
control close to the indoor unit), or in the room (when used as
room thermostat).
▪ If you use 2 user interfaces, you can install 1 user interface at the
indoor unit (for control close to the indoor unit) + 1 user interface
in the room (used as room thermostat).
The procedure differs slightly depending on where you install the
user interface.
#
At the indoor unit
In the room
1
Connect the user interface cable to the indoor unit.
Fix the cable with cable ties to the cable tie mountings.
X2M
X5M
a
b
1 2
a
Main user interface
(a)
b
Optional user interface