REPLACEMENT PARTS

Ordering Parts

When reporting shortages or damages, or ordering repair 

parts, give the complete unit model and serial numbers as 

stamped on the unit’s nameplate. 

Replacement parts for this appliance are available through 

your contractor or local distributor. For the location of your 

nearest distributor, see website 

www.daikincomfort.com 

 

or contact:

EQUIPMENT SUPPORT

DAIKIN NORTH AMERICA LLC

19001 KERMIER ROAD

WALLER, TEXAS 77484

855-770-5678

SAFETY INSTRUCTIONS

 RECOGNIZE THIS SYMBOL AS A 

SAFETY PRECAUTION. 

These installation instructions  cover  the 

outdoor 

installation of single package heating and cooling units.  

See the Specification Sheet applicable to your model for 

information regarding accessories.

*NOTE:  Please contact your distributor or our 

website for the applicable Specification Sheet 

referred to in this manual.

To The Installer

Before installing this unit, please read this manual to 

familiarize  yourself on the specific items which must be 

adhered to, including maximum external static pressure to 

unit, air temperature rise, minimum or maximum CFM and 

motor speed connections. 

Keep this literature in a safe place for future reference.

CAUTION

Sheet metal parts, screws, clips and similar 

items inherently have sharp edges, and it 

is necessary that the installer and service 

personnel exercise caution.

WARNING

Do not connect to or use any device that is 

not design certified by daikin for use with this 

unit. Serious property damage, personal injury, 

reduced unit performance and/or hazardous 

conditions may result from the use of such non-

approved devices.

WARNING

To avoid property damage, personal injury 

or death, do not use this unit if any part has 

been under water. Immediately call a qualified 

service technician to inspect the furnace and to 

replace any part of the control system and any 

gas control having been under water. 

WARNING

This unit must not be used as a “construction 

heater” during the finishing phases of 

construction on a new structure. This type of 

use may result in premature failure of the unit 

due to extremely low return air temperature 

and exposure to corrosive or very dirty 

atmospheres. 

WARNING

HIGH VOLTAGE!

Disconnect all power before 

servicing or installing this unit. 

Multiple power sources may be 

present. Failure to do so may cause 

property damage, personal injury or 

death. 

WARNING

To prevent the risk of property damage, 

personal injury, or death, do not store 

combustible materials or use gasoline or other 

flammable liquids or vapors in the vicinity of 

this appliance. 

Содержание DP16H M Series

Страница 1: ...19 Wiring Diagrams 20 Start UpChecklist 21 Only personnel that have been trained to install adjust service or repair hereinafter service the equipment specified in this manual should service the equip...

Страница 2: ...ence CAUTION Sheet metal parts screws clips and similar items inherently have sharp edges and it is necessary that the installer and service personnel exercise caution WARNING Do not connect to or use...

Страница 3: ...where applicable follow information presented in accepted industry guides such as the ASHRAE Handbooks The manufacturer assumes no responsibility for equipment installed in violation of any code or r...

Страница 4: ...Installations Only To avoid possible property damage or personal injury the roof must have sufficient structural strength to carry the weight of the unit s and snow or water loads as required by local...

Страница 5: ...ES Unit Clearances In situations that have multiple units a 36 minimum clearance is required between the condenser coils Adequate clearance around the unit should be kept for safety service maintenanc...

Страница 6: ...the following bullet points must be observed when installing the unit Unit must be lifted by the four lifting holes located at the base frame corners Lifting cables should be attached to the unit wit...

Страница 7: ...present Failure to do so may cause property damage personal injury or death WARNING HIGH VOLTAGE To avoid personal injury or death due to electrical shock do not tamper with factory wiring The intera...

Страница 8: ...vided for this purpose Do not use the ground lug for connecting a neutral conductor Connect power wiring to the electrical power block located within the main control box Control Box control box Conne...

Страница 9: ...g thermostat sub base NOTE Refer to unit wiring diagrams for thermostat or remote sensor connections CIRCULATING AIR AND FILTERS Ductwork The supply duct from the unit through a wall may be installed...

Страница 10: ...must first be performed in accordance with this manual Damage or repairs due to failure to comply with these requirements are not covered under the warranty After the machines are used for temporary h...

Страница 11: ...r speed setting than the G Y1 and W1 speed setting If Electric Heater kit is installed use the red wire provided with the literature kit to jumper terminal TB1 W1 to an unoccupied speed tap that satis...

Страница 12: ...unning with the reversing valve in the deenergized heating position After giving the unit time to settle out make sure the unit is supplying heated air Note If the outdoor ambient is above 80 F the un...

Страница 13: ...to provide supplementary heat for all heat pump installations in areas where the temperature drops below 45 F It is also a good practice to provide sufficient supplementary heat to handle the entire h...

Страница 14: ...ficiency or equipment damage due to dust and lint build up on internal parts never operate unit without an air filter installed in the return air system Every application may require a different frequ...

Страница 15: ...15 Wiring Example Electric Heat Wiring Example...

Страница 16: ...0 0 8 1960 1045 0 86 0 2 2189 902 0 81 0 2 2234 960 0 86 0 4 2119 943 0 84 0 4 2162 1003 0 90 0 6 2059 979 0 88 0 6 2101 1042 0 93 0 8 2012 1009 0 90 0 8 2053 1073 0 96 0 2 2254 923 0 88 0 2 2300 982...

Страница 17: ...5 7 2 6 5 119 129 125 150 134 148 150 150 7 2 6 5 142 155 150 175 6 9 1 0 3 3 5 Direct Drive Standard Static 1 DP16HM60 208 230 1 60 1 26 9 152 9 EH 1S15 11 3 15 0 54 2 62 5 EH 1S20 15 0 20 0 72 2 83...

Страница 18: ...RB LOCATION EMBOSS FOR THRU THE BASE UTILITIES RETURN 11 X 25 SUPPLY 12 X 17 Horizontal Discharge Vertical Discharge NOTE Refer to IOD 7082 included in the literature pack for installing horizontal du...

Страница 19: ...MODEL NUMBER DP16HM60 kW MINIMUM SCFM AIR FLOW FOR ELECTRIC HEAT 2500 MAXIMUM SCFM HEATER KIT MODEL NUMBER NOMENCLATURE E H S 15 1 2 3 4 5 6 7 Electric Heater Heater Type X Staged S SCR modulating Vol...

Страница 20: ...E INSTALLED NOTES 4 3 2 1 5 6 BLACK BLUE BLUE WITH PINK STRIPE BROWN GREEN GRAY ORANGE PINK PURPLE RED TAN WHITE YELLOW YELLOW WITH PINK STRIPE BK BL BL PK BR GR GY OR PK PU RD TN WH YL YL PK HIGH VOL...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 24: ...o the feedback page PRODUCT REGISTRATION Thank you for your recent purchase Though not required to get the protection of the standard warranty registering your product is a relatively short process an...

Отзывы: