background image

Table of contents

Installation manual

2

DCC601A51

intelligent Tablet Controller

4P414342-1D – 2020.12

Table of contents

1 About the documentation

2

1.1

About this document..................................................................

2

2 General safety precautions

2

2.1

General......................................................................................

2

2.2

Installation site...........................................................................

3

2.3

Electrical ....................................................................................

3

3 Specific installer safety instructions

3

4 About the box

3

4.1

Contents of the kit .....................................................................

3

4.2

Optional equipment ...................................................................

4

5 System overview

4

5.1

About the Daikin intelligent Tablet Controller solution...............

4

5.2

The intelligent Tablet Controller kit ............................................

4

5.3

Compatible (Daikin) equipment .................................................

4

5.4

Additional components in the intelligent Tablet Controller
solution ......................................................................................

4

5.4.1

Daikin-supplied router (ASUS 4G‑AC68U) .................

4

5.4.2

Daikin-supplied tablet (ASUS ZenPad 8.0 Z380M).....

5

6 Preparation

5

6.1

Before installation ......................................................................

5

6.2

Necessary equipment................................................................

5

6.3

Determining installation place ...................................................

5

6.3.1

About installation place and mounting direction..........

5

6.3.2

About required space..................................................

5

6.4

About the location of terminals and switches ............................

6

6.4.1

CPU module................................................................

6

6.4.2

I/O module ..................................................................

6

7 Installation

7

7.1

Installation of the intelligent Tablet Controller hardware ...........

7

7.1.1

To install the 3 intelligent Tablet Controller hardware
components ................................................................

7

7.2

About electric wiring ..................................................................

7

7.2.1

Wiring requirements....................................................

7

7.2.2

Connecting to other equipment...................................

8

7.2.3

Connecting the power supply to all modules ..............

9

7.2.4

Connecting the LAN cable .......................................... 10

7.3

About the installation of the Daikin-supplied router ...................

10

8 Disposal

10

9 Copyright and trademarks

10

10 Technical data

10

10.1

Environmental conditions ..........................................................

10

10.2

Electrical cabinet .......................................................................

10

10.3

Power consumption specifications ............................................

10

10.4

Other intelligent Tablet Controller specifications .......................

11

10.5

Schematic setup of the intelligent Tablet Controller ..................

11

1

About the documentation

1.1

About this document

Target audience

Authorised installers

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

Installation manual:

▪ Installation instructions

▪ Format: Paper (supplied in the kit)

Installer reference guide:

▪ Preparation of the installation, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

General safety precautions

Please  read  these  general  safety  precautions  carefully  before
installing  air  conditioning  equipment,  and  be  sure  to  install  the
equipment correctly.

Failure  to  follow  these  instructions  properly  may  result  in  property
damage or personal injury, which may be serious depending on the
circumstances.

After  completing  the  installation,  make  sure  the  power  supply  and
controller modules operate properly during the startup operation.

Meaning of warnings and symbols

These  safety  messages  are  used  to  attract  your  attention.  The
meaning of each safety message is described below:

WARNING

Indicates  a  situation  that  could  result  in  death  or  serious
injury.

CAUTION

Indicates a situation that could result in minor or moderate
injury.

DANGER

Indicates a situation that results in death or serious injury.

DANGER: RISK OF EXPLOSION

Indicates a situation that could result in explosion.

INFORMATION

Indicates useful tips or additional information.

NOTICE

Indicates  a  situation  that  could  result  in  equipment  or
property damage.

2.1

General

If  you  are  NOT  sure  how  to  install  or  operate  the  unit,  contact  your
dealer.

Содержание DCC601A51

Страница 1: ...Installation manual intelligent Tablet Controller English Installation manual intelligent Tablet Controller DCC601A51 ...

Страница 2: ...t audience Authorised installers Documentation set This document is part of a documentation set The complete set consists of Installation manual Installation instructions Format Paper supplied in the kit Installer reference guide Preparation of the installation reference data Format Digital files on http www daikineurope com support and manuals product information Latest revisions of the supplied ...

Страница 3: ... performed in accordance with the wiring diagram supplied with the product Make sure to install earth wiring Do NOT earth the unit to a utility pipe surge absorber or telephone earth Incomplete earth may cause electrical shock Make sure to use a dedicated power circuit NEVER use a power supply shared by another appliance Make sure to install the required fuses or circuit breakers Make sure to inst...

Страница 4: ...ller kit see 10 5 Schematic setup of the intelligent Tablet Controller 4 11 Before installing the intelligent Tablet Controller kit modules draw up an efficient plan of work using this schematic and based on the real environment it needs to be installed in 5 3 Compatible Daikin equipment The intelligent Tablet Controller solution can connect to certain Daikin units that provide a DIII NET communic...

Страница 5: ...ments Location Indoor inside an electrical cabinet The electrical cabinet must be lockable or designed to be opened only with a special tool The key or tool should be available only to service personnel must be installed in a space with no access for the general public must comply with the applicable legislation must have ingress protection class of IP4X or higher however make sure enough ventilat...

Страница 6: ...itches a RESET Button for restarting the CPU module and I O module k DIP SW Reserved for servicing Factory default all switches are set to OFF OFF n BACKUP Switch for turning on off the backup power supply for retaining the current settings provided by the internal battery Factory default OFF OFF This will be set to the ON ON position during commissioning q Lever To assist mounting dismounting the...

Страница 7: ...perating condition CPU ALIVE ALARM Normal Blink OFF Hardware failure OFF ON Power interruption OFF OFF Communication failure between CPU module and I O module for 10 seconds or more ON Blink 7 Installation 7 1 Installation of the intelligent Tablet Controller hardware The intelligent Tablet Controller components are to be mounted onto a 35 mm DIN rail inside an electrical cabinet For more informat...

Страница 8: ...on terminal sized for maximum 4 mm According to applicable legislation Solid or stranded wire allowed The internal protection of the WAGO PSU is fused at 2 5 A 250 V 24 V DC power supply to the CPU module According to applicable legislation Solid or stranded wire allowed USB cable 5 m Commercial USB 2 0 cable type A to type B connector provided in the intelligent Tablet Controller kit a Total leng...

Страница 9: ...ternally So you can use any one of them However you can only connect up to 2 wires simultaneously to each COM terminal If applicable connect the I O module s COM terminal to the negative side of the device terminals 7 2 3 Connecting the power supply to all modules For all wiring requirements see 7 2 1 Wiring requirements 47 To connect the power supply to all modules 1 Connect the power supply to t...

Страница 10: ...e data backup battery Both intelligent Tablet Controller modules are marked with the following symbol This means that electrical and electronic products may not be mixed with unsorted household waste Do NOT try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and of other parts must be done by an authorized installer and must comply with applicable...

Страница 11: ...chematic setup of the intelligent Tablet Controller USB 230 V AC RJ 45 F1 F2 P1 P2 F1 F2 P1 P2 F1 F2 P1 P2 F1 F2 OUT IN F1 F2 http cloud daikineurope com DIII NET POWER I O IF CPU IF LAN F1 F2 Di1 Di4 d e f i i i h j k 24 V DC c b g a l l L N a WAGO power supply unit b CPU module c I O module d Optional Daikin supplied tablet e Daikin Cloud Service f Daikin Cloud Service g LAN gateway optional Dai...

Страница 12: ...4P414342 1D 2020 12 Copyright 2015 Daikin 4P414342 1 D 0000000Y Verantwortung für Energie und Umwelt ...

Отзывы: