background image

Содержание Daikin Altherma 3 H F+W

Страница 1: ...ration manual Daikin Altherma 3 H F W EABH16DF6V 7 EABH16DF9W 7 EABX16DF6V 7 EABX16DF9W 7 EAVH16S18DA6V 7 EAVH16S23DA6V 7 EAVH16S18DA9W 7 EAVH16S23DA9W 7 EAVX16S18DA6V 7 EAVX16S23DA6V 7 EAVX16S18DA9W...

Страница 2: ...Check if he has filled in the installer settings tables If NOT request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a d...

Страница 3: ...refrigerant of oil and of other parts MUST be done by an authorised installer and MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling...

Страница 4: ...the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a space Cool down a space if a heating cooling heat pump model is installed Produce domestic ho...

Страница 5: ...to show a help text related to the current page if available e Right dial The LCD shows an arc on the right side of the display when you can use the right dial Turn then press the right dial Change a...

Страница 6: ...Space heating cooling a Selected submenu Possible actions on this screen Go through the list Enter the submenu Enable disable breadcrumbs Submenu Description 0 or Malfunctioning Restriction Only displ...

Страница 7: ...4 Detailed screen with values Example a b c a b c 7 2 1 Time date Hours 11 30 Minutes a Settings b Values c Selected setting and value Possible actions on this screen Go through the list of settings...

Страница 8: ...on mode to use To tell the system which space operation to use you can You can Location Check which space operation mode is currently used Home screen Set the space operation mode permanently Main men...

Страница 9: ...FORMATION When the DHW tank mode is reheat the risk for capacity shortage and comfort problem is significant In case of frequent reheat operation space heating cooling function is regularly interrupte...

Страница 10: ...nformation To change the user permission level You can change the user permission level as follows 1 Go to B User profile User profile B 2 Enter the applicable pin code for the user permission level B...

Страница 11: ...ious action 4 Confirm the changes Result The schedule for Monday is defined The value of the last action is valid until the next programmed action In this example Monday is the first day you programme...

Страница 12: ...Thu Tue Sun User defined 1 2 Select Rename Delete Rename Select 3 optional To delete the current schedule name browse through the character list until is displayed then press to remove the previous ch...

Страница 13: ...ule 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection sta...

Страница 14: ...he scheduled room temperature until the next scheduled action Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about DHW...

Страница 15: ...en 7 2 Symptom You are feeling too cold hot in your living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature See 4 4 2 T...

Страница 16: ...If hydraulic balancing is not sufficient change the pump limitation settings 9 0D and 9 0E if applicable Various malfunctions Check if or is displayed on the home screen of the user interface See 7 1...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...4P644480 1A 2021 09 Copyright 2018 Daikin 4P644480 1 A 0000000 Verantwortung f r Energie und Umwelt...

Отзывы: