20
ECONO operation
ECONO operation enables efficient operation by limiting the maximum power consumption.
This function is useful to prevent the circuit breaker from tripping when the unit operates alongside other
appliances on the same circuit.
[Example]
Normal operation
ECONO operation
•
In case the air conditioner and other appliances which
require high power consumption are used at the same
time, a circuit breaker may trip if the air conditioner
operates with its maximum capacity.
•
The maximum power consumption of the air conditioner is
limited by using ECONO operation.
The circuit breaker will hardly trip even if the air
conditioner and other appliances are used at same time.
OUTDOOR UNIT QUIET operation
OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency
and fan speed of the outdoor unit. This function is convenient during the night-time operation.
[Example]
Using the OUTDOOR UNIT QUIET operation during the night.
•
The noise level of the
outdoor unit will be lower.
This function is useful
when you need to
consider the noise for
your neighbourhood.
ECONO / OUTDOOR UNIT
QUIET Operation
01_EN_3P472684-1.indd 20
6/13/2017 9:01:37 AM
Содержание CTXJ25RVMAW
Страница 43: ...Memo 42...