Si041401EB
Swing Motors
Removal Procedure
19
8. Swing Motors
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Caution
When reassembling, do not confuse the installing order of the 2 motor for horizontal
blades and the colors of the connectors.
If you set the connectors or motors opposite, the horizontal blades do not move
smoothly or noise may be heard.
Step
Procedure
Points
1
2
Remove the 2 screws
fixed to the installation
plate.
Hold the indoor unit up
with a wooden base.
Place a plastic sheet under
the drain pan to prevent
wetting the floor with the
remaining drain.
If the drain hose is
embedded in the wall,
disconnect the drain hose
beforehand.
When the pipings are
disconnected, protect the
both openings of pipe side
and unit side from entering
of moisture.
Carry out the removal work
with 2 wrenches.
3
4
Disconnect the gas
piping and the liquid
piping.
Detach the indoor unit
from the installation
plate.
5
Remove the screw, and
then the drain hose.
(R20016)
(R20017)
Gas piping
Drain hose
Liquid piping
Drain hose
(R20018)