27
ACCESSORIES
Heat Kit Applications
Type / Model
24B14-A*
30C14-A*
36C14-A*
48C14-A*
42D14-A*
†
48D14-A*
††
60D14-A*
†††
HKSX03XC
X
X
X
HKSX05XC
X
X
X
X
X
X
X
HKSX06XC
X
X
X
X
X
X
X
HKSX08XC
X
X
X
X
X
X
X
HKSX10XC
X
X
X
X
X
X
X
HKSX15XF*
X
X
X
X
X
HKSX20XF*
X
X
X
X
X
HKSC05XC
X
X
X
X
X
X
X
HKSC08XC
X
X
X
X
X
X
X
HKSC10XC
X
X
X
X
X
X
X
HKSC15XA
X
X
X
X
X
HKSC15XB
X
X
X
X
X
HKSC15XF*
X
X
X
X
X
HKSC19CA*
X
X
HKSC19CB*
X
X
HKSC20DA
X
X
X
HKSC20DB
X
X
X
HKSCX20XF*
X
X
X
X
X
HKSC25DC*
X
X
* Revision level that may or may not be designated.
Refer to the minimum airflow requirements for each of the heat kits.
DVPTC
†For match up with a 2 ton outdoor unit: Heater kit application shall not exceed 10 kW.
Airflow for 5 kW up to 10 kW heater kits shall be set to 850 cfm speed tap of ON-ON-ON.
††For match up with a 3 ton outdoor unit: Heater kit application shall not exceed 15 kW.
Airflow for 5 kW up to 15 kW heater kits shall be set to 1400 cfm speed tap of ON-ON-OFF.
†††For match up with a 3.5 ton outdoor unit: Heater kit application shall not exceed 20 kW.
Airflow for 5 kW up to 20 kW heater kits shall be set to 1620 cfm speed tap of ON-ON-OFF
** 3 kW heater kit is not applicable for this indoor application.
3
5
6
8
10
15
19
20
21 or 25
24B
550
650
700
800
850
30C
600
700
750
875
950
36C
850
900
1000
1200
1440
1500
48C
850
900
1000
1200
1440
1500
42D
†
850**
1250
1300
1500
1550
1720
1800
48D
††
1250
1300
1500
1550
1720
1815
1850
60D
†††
1250
1300
1500
1550
1780
1850
1850
†For match up with a 2 ton outdoor unit: Heater kit application shall not exceed 10 kW.
Airflow for 5 kW up to 10 kW heater kits shall be set to 850 cfm speed tap of ON-ON-ON.
††For match up with a 3 ton outdoor unit: Heater kit application shall not exceed 15 kW.
Airflow for 5 kW up to 15 kW heater kits shall be set to 1300 cfm speed tap of ON-OFF-ON.
†††For match up with a 3.5 ton outdoor unit: Heater kit application shall not exceed 20 kW.
Airflow for 5 kW up to 20 kW heater kits shall be set to 1500 cfm speed tap of ON-OFF-OFF
** 3 kW heater kit is not applicable for this indoor application.
DV**PTC
HEATER (kW)
Minimum CFM required for Heater Kits
Note: Airflow data shown applies to the electric heat only in either legacy mode or communicating mode operation
DV**PTC14**