Operation manual

4

4P563995-1 2019.01

BRC7FA532F(B) + BRC7FB532F(B)

Wireless remote controller kit

Operation range

Refer  to  the  operation  manual  provided  with  the
indoor unit or with the outdoor unit.

If  the  indoor  temperature  or  humidity  is  beyond
operating  conditions  as  listed  in  the  indoor  unit  or
outdoor unit manuals, it may happen 

- that safety devices work, 
- that the air conditioner does not operate,
- that water drips from the indoor unit.

The  setting  temperature  range  of  the  remote
controller is 16°C to 32°C.

Operation procedure

To protect the unit, turn on the main power switch 6
hours before operation.

If  the  main  power  supply  is  turned  off  during
operation,  operation  will  restart  automatically  after
the power turns back on again.

Cooling,  Heating,  Automatic,  Fan  and
Program dry operation

Operate in the following order:

AUTOMATIC  OPERATION  can  be  selected  only  by
heat pump system or heat recovery VRV system.

For systems without a cool/heat changeover remote 
control switch

See figure 1

Press  the  OPERATION  MODE  SELECTOR  button
several times and select the OPERATION MODE of
your choice as follows:

- COOLING operation ......................................

- HEATING operation .......................................

- AUTOMATIC operation.................................

- In this operation mode, COOL/HEAT 

changeover is automatically conducted.

- FAN operation................................................

- DRY operation ...............................................

- The function of this program is to decrease 

the humidity in your room with the minimum 
temperature decrease.

- The set point is the air temperature when 

starting operation by dry operation.

- Micro computer automatically determines 

TEMPERATURE and FAN SPEED.

- This system does not go into operation if the 

room temperature is below 16°C.

Press ON/OFF button.
OPERATION  lamp  lights  up  or  goes  off  and  the
system starts or stops OPERATION.

For systems with cool/heat changeover remote control 
switch

See figure 4
Select  OPERATION  MODE  with  the  COOL/HEAT
CHANGEOVER  REMOTE  CONTROL  SWITCH  as
follows.

Press  OPERATION  MODE  SELECTOR  button
several times and select "

". 

See  "For  systems  without  a  cool/heat  changeover
remote  control  switch"  on  page 4  
for  details  on  dry
operation.
(This  operation  is  only  available  during  dry
operation.)

Press ON/OFF button.
OPERATION  lamp  lights  up  or  goes  off  and  the
system starts or stops OPERATION.

1

OPERATION MODE SELECTOR

2

ON/OFF

Do not turn OFF power immediately after the
unit stops. Then, wait no less than 5 minutes.
Water  is  leaking  or  there  is  something  else
wrong with the unit.

1

OPERATION MODE SELECTOR

COOLING operation.........................

HEATING operation..........................

FAN operation ..................................

DRY operation ..................................

2

ON/OFF

Do not turn OFF power immediately after the
unit stops. Then, wait no less than 5 minutes.
Water  is  leaking  or  there  is  something  else
wrong with the unit.

4PEN563995-1.book  Page 4  Friday, January 25, 2019  12:21 PM

Содержание BRC7FA532FB

Страница 1: ...OPERATION MANUAL BRC7FA532F BRC7FA532FB BRC7FB532F BRC7FB532FB Wireless remote controller kit 4PEN563995 1 book Page 1 Friday January 25 2019 12 21 PM...

Страница 2: ...N TIME TEMP UP DOWN CANCEL RESERVE TIMER MODE 5 7 24 25 9 8 10 17 16 14 15 12 13 11 22 23 21 18 19 2 1 1 2 3 4 6 1 2 3 UNITNO CODE UNITNO MODE TIMER RESERVECANCEL DOWN UP TEST SWING FAN TIME TEMP ON O...

Страница 3: ...re electric shocks or fire hazards Do not attempt to install or repair the air conditioner yourself Improper workmanship may result in water leakage electric shocks or fire hazards Please contact your...

Страница 4: ...elect OPERATION MODE 16 FILTER SIGN RESET BUTTON Refer to the section of MAINTENANCE in the operation manual attached to the indoor unit 17 INSPECTION TEST OPERATION BUTTON This button is used only by...

Страница 5: ...g the remote controller in the remote controller holder Install the remote controller holder to a wall or a pillar with the attached screw Make sure the remote controller transmits How to put the batt...

Страница 6: ...operation DRY operation The function of this program is to decrease the humidity in your room with the minimum temperature decrease The set point is the air temperature when starting operation by dry...

Страница 7: ...ntrol the fan speed in order to protect the unit The movable limit of the flap is changeable Contact your dealer for details Up and down adjustment Press the AIR FLOW DIRECTION ADJUST button to select...

Страница 8: ...stem is installed as shown below it is necessary to designate the master remote controller For Heat pump system When one outdoor unit is connected with several indoor units For Heat recovery system Wh...

Страница 9: ...controls up to 16 indoor units All indoor units are equally set Two remote controller control system Two remote controllers control one indoor unit In case of group control system one group of indoor...

Страница 10: ...ion code a1 if on the remote controller Notify and inform the model name and what the malfunction code indicates to your dealer Not malfunction of the air conditioner The following symptoms do not ind...

Страница 11: ...and the unit stops When the noise is gone the unit automatically restarts Example Reason The indoor unit makes a PEEE receiving sound When operation changeover is under control the control is set to t...

Страница 12: ...4P563995 1 2019 01 Copyright 2019 Daikin 4PEN563995 1 book Page 1 Friday January 25 2019 12 21 PM...

Отзывы: