Daikin BRC7FA532FB Скачать руководство пользователя страница 4

Operation manual

2

4P563995-1 2019.01

BRC7FA532F(B) + BRC7FB532F(B)

Wireless remote controller kit

Names  and  functions  of  the  operating
section

See figure 1

, (figure 1B shows the remote controller with

front cover opened)

1

DISPLAY "

" (SIGNAL TRANSMISSION)

This lights up when a signal is being transmitted.

2

DISPLAY "

" "

" "

" "

" "

" (OPERATION

MODE)
This display shows the current OPERATION MODE.

3

DISPLAY "

" (SET TEMPERATURE)

This display shows the set temperature.

4

DISPLAY "

"(PROGRAMMED TIME)

This  display  shows  PROGRAMMED  TIME  of  the
system start or stop.

5

DISPLAY "

" (SWING FLAP)

Refer  to  "AIR  FLOW  DIRECTION  ADJUST"  on
page 5.

6

DISPLAY "

" "

" (FAN SPEED)

The display shows the set fan speed.

7

DISPLAY  "

"  (INSPECTION/  TEST  OPERA-

TION)
When 

the 

INSPECTION/TEST 

OPERATION

BUTTON  is  pressed,  the  display  shows  the  system
mode is in.

8

ON/OFF BUTTON
Press the button and the system will start. Press the
button again and the system will stop.

9

FAN SPEED CONTROL BUTTON
Press  this  button  to  select  the  fan  speed,  HIGH  or
LOW, of your choice.

10

TEMPERATURE SETTING BUTTON
Use  this  button  for  SETTING  TEMPERATURE
(Operates with the front cover of the remote controller
closed.)

11

PROGRAMMING TIMER BUTTON
Use  this  button  for  programming  "START  and/or
STOP"  time.  (Operates  with  the  front  cover  of  the
remote controller opened.)

12

TIMER MODE START/STOP BUTTON
Refer to "TIMER MODE START/STOP" on page 6.

13

TIMER RESERVE/CANCEL BUTTON
Refer to "PROGRAMMING TIME" on page 6.

14

AIR FLOW DIRECTION ADJUST BUTTON
Refer  to  "AIR  FLOW  DIRECTION  ADJUST"  on
page 5.

15

OPERATION MODE SELECTOR BUTTON
Press this button to select OPERATION MODE.

16

FILTER SIGN RESET BUTTON
Refer  to  the  section  of  MAINTENANCE  in  the
operation manual attached to the indoor unit.

17

INSPECTION/TEST OPERATION BUTTON
This button is used only by qualified service persons
for maintenance purposes.

See figure 3

, (receiver on decoration panel)

18

EMERGENCY OPERATION SWITCH
This  switch  is  readily  used  if  the  remote  controller
does not work.

19

RECEIVER
This receives the signals from the remote controller.

20

OPERATING INDICATOR LAMP (Red)
This  lamp  stays  lit  while  the  air  conditioner  runs.  It
flashes when the unit is in trouble.

21

TIMER INDICATOR LAMP (Green)
This lamp stays lit while the timer is set.

22

AIR  FILTER  CLEANING  TIME  INDICATOR  LAMP
(Red)
Lights up when it is time to clean the air filter.

23

DEFROST LAMP (Orange)
Lights up when the defrosting operation has started.

See figure 4

, (cool/heat changeover switch)

In a VRV system, the wireless remote controller can be
used together with a cool/heat changeover switch.

24

FAN/AIR CONDITIONING SELECTOR SWITCH

Set the switch to "

" (FAN) for FAN and "

(A/C) for HEAT or COOL.

25

COOL/HEAT CHANGEOVER SWITCH

Set  the  switch  to  "

"  (COOL)  for  COOL  and  "

"

(HEAT) for HEAT

NOTE

For  the  sake  of  explanation,  all
indications are shown on the display in
figure 1  contrary  to  actual  running
situations.

If  the  air  filter  cleaning  time  indicator
lamp  lights  up,  clean  the  air  filter  as
explained  in  the  operation  manual
provided with the indoor unit.
After  cleaning  and  reinstalling  the  air
filter,  press  the  filter  sign  reset  button
on  the  remote  controller.  The  air  filter
cleaning  time  indicator  lamp  on  the
receiver will go out.

The  defrost  lamp  will  flash  when  the
power  is  turned  on.  This  is  not  a
malfunction.

4PEN563995-1.book  Page 2  Friday, January 25, 2019  12:21 PM

Содержание BRC7FA532FB

Страница 1: ...OPERATION MANUAL BRC7FA532F BRC7FA532FB BRC7FB532F BRC7FB532FB Wireless remote controller kit 4PEN563995 1 book Page 1 Friday January 25 2019 12 21 PM...

Страница 2: ...N TIME TEMP UP DOWN CANCEL RESERVE TIMER MODE 5 7 24 25 9 8 10 17 16 14 15 12 13 11 22 23 21 18 19 2 1 1 2 3 4 6 1 2 3 UNITNO CODE UNITNO MODE TIMER RESERVECANCEL DOWN UP TEST SWING FAN TIME TEMP ON O...

Страница 3: ...re electric shocks or fire hazards Do not attempt to install or repair the air conditioner yourself Improper workmanship may result in water leakage electric shocks or fire hazards Please contact your...

Страница 4: ...elect OPERATION MODE 16 FILTER SIGN RESET BUTTON Refer to the section of MAINTENANCE in the operation manual attached to the indoor unit 17 INSPECTION TEST OPERATION BUTTON This button is used only by...

Страница 5: ...g the remote controller in the remote controller holder Install the remote controller holder to a wall or a pillar with the attached screw Make sure the remote controller transmits How to put the batt...

Страница 6: ...operation DRY operation The function of this program is to decrease the humidity in your room with the minimum temperature decrease The set point is the air temperature when starting operation by dry...

Страница 7: ...ntrol the fan speed in order to protect the unit The movable limit of the flap is changeable Contact your dealer for details Up and down adjustment Press the AIR FLOW DIRECTION ADJUST button to select...

Страница 8: ...stem is installed as shown below it is necessary to designate the master remote controller For Heat pump system When one outdoor unit is connected with several indoor units For Heat recovery system Wh...

Страница 9: ...controls up to 16 indoor units All indoor units are equally set Two remote controller control system Two remote controllers control one indoor unit In case of group control system one group of indoor...

Страница 10: ...ion code a1 if on the remote controller Notify and inform the model name and what the malfunction code indicates to your dealer Not malfunction of the air conditioner The following symptoms do not ind...

Страница 11: ...and the unit stops When the noise is gone the unit automatically restarts Example Reason The indoor unit makes a PEEE receiving sound When operation changeover is under control the control is set to t...

Страница 12: ...4P563995 1 2019 01 Copyright 2019 Daikin 4PEN563995 1 book Page 1 Friday January 25 2019 12 21 PM...

Отзывы: