Daikin BRC7E61W Скачать руководство пользователя страница 18

Remote Controller (Wireless Type)

OH08-1

64

Control Systems

2.3.5

Installation

„

Safety Precautions

Please read these “SAFETY PRECAUTIONS” carefully before installing air conditioning unit and be sure to 
install it correctly.
After completing installation, conduct a trial operation to check for faults and explain to the customer how to 
operate the air conditioner and take care of it with the aid of the operation manual. Ask the customer to 
store the installation manual along with the operation manual for future reference.

Meaning of CAUTION notices

CAUTION

Failure to observe these instructions properly may result in property damage or personal injury, which may 
be serious depending on the circumstances.

CAUTION

z

Refer also to the installation manual attached to the indoor unit and the installation manual attached to 
the decoration panel.

z

Confirm that following conditions are satisfied prior to installation.

z

Ensure that noting interrupts the operation of the wireless remote controller. (Ensure that there is 
neither a source of light nor fluorescent lamp near the receiver.  Also, ensure that the receiver is not 
exposed of direct sun light.)

z

Ensure that the operaiton display lamp and other indicators are easy to see.

z

The installation position of this kit is 1 position of the decoration panel.  Therefore, confirm that its 
position is set so that the single form the wireless remote controller can be easily transmitted and its 
display can be easily seen.

z

If both this kit and fresh air intake kit are installed, only one duct chamber shall be used.  Refer to the 
installation manual of the fresh air intake kit (optional hand book).

„

Before Installation

(1) Accessories
Check if the following accessories are included with your unit.

(2) Note to the Installer

z

Be sure to instruct the customer how to properly operate the system showing him/her the attached 
operation manual.

Name

Receiver

Wireless remote 

controller

Transmission

Remote controller 

holder

Screw for installing 

transmission

Screw for installing 

remote controller 

holder

Quantity

1 set

1 pc.

1 set

1 pc.

2 pcs.

2 pcs.

Shape

Name

Clamp

Dry cell battery 

LR03 (AM4)

Unit No. label

Field setting label

Operation manual

Installation manual

Quantity

1 pc.

2 pcs.

1 pc.

1 pc.

1 pc.

1 pc.

Shape

Содержание BRC7E61W

Страница 1: ...low typ e is mou nted into th e ind oor u nit T h is u nit su p p orts th e th ree sp eed a irflow ra te c ontrol H H H L 2 3 2 F u n c tio n Sig na l rec eiv er u nit Insta lled typ e Sig na l rec e...

Страница 2: ...D RAIN PIPING SID E RE CE IV E R INSTALLATION PROCE D U RE RE FRIG E RANT PIPING SID E RE CE IV E R D E TAIL W IRE LE SS RE MOTE CONTROLLE R K IT FOR E ACH D E CORATION PANE L RE MOTE CONTROLLE R D I...

Страница 3: ...f th e Operating S ection 1 1 3 2 1 1 1 2 8 10 13 11 12 15 14 16 17 9 1 3 4 6 2 5 7 DOWN FAN UP ON OFF M H L C hr hr TEST MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIME TEMP ON OFF M H L C hr h...

Страница 4: ...AMMING TIMER BU TTON Use this button for programming START and or STOP time Operates with the front cover of the remote controller opened 12 TIMER MODE START STOP BU TTON Refer to page 57 13 TIMER RES...

Страница 5: ...mote controller Direct the transmitting part of the remote controller to the receiv ing part of the air conditioner If something blocks the transmitting and receiving path of the indoor unit and the r...

Страница 6: ...r normal use batteries last about a year However change them whenever the indoor unit doesn t respond or responds slowly to commands or if the display becomes dark CAUTIONS z Replace all batteries at...

Страница 7: ...te in the following order z AUTOMATIC OPERATION can be selected only by Heat pump split system or Heat recovery VRV system z For cooling only type COOLING and FAN and DRY operation are able to select...

Страница 8: ...mp lights up or goes off and the system starts or stops OPERATION z The fan may keep on running for about 1 minute after the heating operation stops for removing the heat in the indoor unit z The air...

Страница 9: ...purchase 3 Adjustment For programming TEMPERATURE FAN SPEED and AIR FLOW DIRECTION follow the procedure shown below TEMPERATURE SETTING Press TEMPERATURE SETTING button and program the setting temper...

Страница 10: ...facing downward air flow direction may change unexpectedly There is nothing wrong with the equipment This serves to prevent dew formed on parts in the air discharge outlet from dripping z Operation m...

Страница 11: ...ocedure ends The display or changes from flashing light to a constant light TIMER CANCEL Press the TIMER OFF button to cancel programming The display vanishes For example When the timer is programmed...

Страница 12: ...peration mode between FAN DRY and COOL When the indoor unit with master remote controller is set to HEAT you can switch over operation mode between FAN and HEAT When the indoor unit with master remote...

Страница 13: ...rates with the previously set air flow direction STOP Press the EMERGENCY OPERATION switch again 7 Precautions for Group Control System or Two Remote Controller Control System This system provides two...

Страница 14: ...tioner the communication between the units is cut off and the unit stops When the noise is gone the unit automatically restarts III NO CHANGEOVER IS AVAILABLE BETWEEN HEATING AND COOLING MODES z The i...

Страница 15: ...until the indoor unit beeps and perform the following operation according to the number of beeps Number of beeps 3 short beeps Perform all steps from 3 to 6 1 short beep Perform 3 and 6 steps 1 long...

Страница 16: ...of the same number Signal transmitted from a remote controller of a different number cannot be accepted If the number is not mentioned it is considered as 1 2 The system operates but it does not suff...

Страница 17: ...the unit does not work at all Remedial action Check the malfunction code A1 UF on the remote control and contact the place of purchase See page 60 MODE TIMER RESERVE CANCEL DOWN UP TEST SWING FAN TIM...

Страница 18: ...ther a source of light nor fluorescent lamp near the receiver Also ensure that the receiver is not exposed of direct sun light z Ensure that the operaiton display lamp and other indicators are easy to...

Страница 19: ...roller by sliding it in the direction of the arrow 2 Insert the attached dry cell batteries Properly insert set the batteries by matching the and polarity marks as indicated Then close the cover as be...

Страница 20: ...and make the multiple setting as shown below 3 Stick the Unit No label on the air outlet of the decoration panel and the back of the wireless remote controller PRECAUTIONS Set the Unit No of the rece...

Страница 21: ...harnesses from the transmission using provided clamps Installation of the Decoration Panel Install the decoration panel as described in the Installation Manual supplied with the decoration panel NOTE...

Страница 22: ...re 1 When in the normal mode press the button for a minimum of four seconds and the FIELD SET MODE is entered 2 Select the desired MODE NO with the button 3 Push the button and select the FIRST CODE N...

Страница 23: ...tting for spacing time of display time to clean air filter Setting for when filter contamination is heavy and spacing time of display time to clean air filter is to be halved Ultra long life type ligh...

Отзывы: