Страница 1: ...Be sure to read this installation manual before installing this product BRC1E62 WIRED REMOTE CONTROLLER INSTALLATION MANUAL ...
Страница 2: ...ntroller buttons 10 5 Power on 12 6 Field settings 13 7 Test operation method in the case of SPLIT system 16 8 Checking procedure of Malfunction Error History 19 9 Registration method of the Maintenance Contact 20 10 Confirmation of registered details 21 11 Clock Calendar 22 12 Language 23 13 Prohibit buttons 24 14 Prohibit Function 25 ...
Страница 3: ...roper installation may result in electric shocks or a fire Be sure to use only the specified accessories and parts for installation work Failure to use the specified parts may result in the remote controller falling down electric shocks or a fire Install the remote controller on a foundation that can withstand its mass Insufficient strength may result in the remote controller falling down and caus...
Страница 4: ...re is machinery which emits electromagnetic waves Electromagnetic waves may disturb the control system and cause a malfunction of the equipment 4 Where flammable gas may leak where there is carbon fibre or ignitable dust suspensions in the air or where volatile flammables such as thinner or gasoline are handled Operating the unit in such conditions may result in a fire 5 High temperature area or d...
Страница 5: ...f the wiring through hole on the controller lower case when making the hole Ø8 10 External view of the remote controller Through hole Ø8 10 Lower case through hole 48 5 40 3 3 Remove upper case Insert a screwdriver in the recess of lower case to remove the upper case 2 points Upper case Lower case Screwdriver Insert and twist the screwdriver lightly for removal Remote controller Printed Circuit Bo...
Страница 6: ...ke and then remove burr with a file or the like Cut off thin area hatched area with nippers or the like and then remove burr with a file or the like 3 5 Conduct wiring 1 Switch box and transmission wiring are not attached 2 Do not directly touch the Printed Circuit Board CAUTION Wiring Specifications Wiring Type Sheathed vinyl cord or cable 2 cores 1 Wiring Size 0 75 1 25 mm2 Wiring Length Max 500...
Страница 7: ... 2 wires Sheath stripping length Approx 150 mm for top left outlet Approx 200 mm for top center outlet Connect the terminals P P1 N P2 of the remote controller to the terminals P1 P2 of the indoor unit P1 and P2 have no polarities 3 5 1 Back outlet Wiring fixing guideline Lower case P1 Indoor unit P2 Upper case Clamp Wiring fixing point Printed Circuit Board Cross section Secure the wiring at the ...
Страница 8: ...As shown to the left install wiring retainer in order to prevent wiring pinching Indoor unit Wiring retainer Wiring retainer Upper case Lower case Upper case Wiring Cross section P1P2 Printed Circuit Board 3 5 4 Top center outlet Indoor unit Wiring retainer Upper case Lower case P1P2 Printed Circuit Board ...
Страница 9: ...oller through top center outlet or back outlet perform wiring through the outlet hole in the lower case before it is wall install 3 6 1 In the case of installation on the wall Secure by using attached wood screws 2 pcs Wood screws M3 5 16 3 6 2 In the case of installation on the switch box Secure by using attached small screws 2 pcs Small screws M4 16 Switch box field supply Use optional accessory...
Страница 10: ...allation face as possible And do not tighten the installation screws too much not to deform the lower case CAUTION 3 7 Install the upper case as original condition Align the upper case with tabs of the lower case 6 points inset and install the upper case Install the wiring with care to prevent pinching Peel off a protective seal which is attached on the upper case ...
Страница 11: ...ding on connected model 4 Up button Used to raise the set temperature Use to highlight the item above the current selection The highlighted items will be scrolled continuously when the button is kept pressed Used to change the item selected 5 Down button Used to lower the set temperature Use to highlight the item below the current selection The highlighted items will be scrolled continuously when ...
Страница 12: ...s Indoor unit AirNet Address Outdoor unit AirNet Address Error History Indoor Unit Status Outdoor Unit Status Forced Fan ON Switch Main Sub Controller Filter Indicator Test Filter Auto Clean Brush Filter Ind Disable Filter Auto Clean Depending on connected model Operate the button during backlight lit However ON OFF may be operated concurrently with backlight lit When 1 indoor unit is controlled b...
Страница 13: ...ower in the case of 1 indoor unit controlled by 2 remote controllers Error code U5 is displayed in the connection checking screen Select the sub remote controller by pressing the Mode Selector button of either one of the remote controllers for 4 seconds or longer If the Basic screen is not displayed more than 2 minutes after Sub RC display turn off the power and check the wiring CAUTION When selec...
Страница 14: ...ight SECOND CODE NO of the FIRST CODE NO to be changed and select desired SECOND CODE NO by using Down Up button Multiple identical mode number settings are available In the case of group setting all of SECOND CODE NO which may be set are displayed as is changed to SECOND CODE NO to be set And SECOND CODE NO means no function Basic screen 6 1 Fan Press and hold Cancel button for 4 seconds or longe...
Страница 15: ...er Contamination Heavy Light Setting for spacing time of display time to clean air filter Setting for when filter contamination is heavy and spacing time of display time to clean air filter is to be halved Ultra long life filter Light Approx 10 000 hrs Heavy Approx 5 000 hrs Long life filter Approx 2 500 hrs Approx 1 250 hrs Standard filter Approx 200 hrs Approx 100 hrs 1 Long life filter type Set...
Страница 16: ...low direction range setting Upper Normal Lower 6 Setting the external static pressure Setting according to the connected duct resistance Normal High static pressure Low static pressure For FHYK Normal High ceiling 15 25 3 Drain pump operation with humidifying Equipped Not equipped 1c 1 Thermostat sensor in remote controller For Auto mode and Setback function only Not use Use 1e 2 Setback function ...
Страница 17: ...shock After air purge by vacuum pump refrigerant pressure may not rise even though the stop valve is opened The reason is that refriger ant system of the outdoor unit is blocked by electric expansion valve or the like Operation is no problem 7 3 Press Mode Selector button to select Cool mode 7 4 Press and hold Cancel button for 4 seconds or longer Service Settings menu is displayed 7 5 Select Test...
Страница 18: ...on finishes If the interior finish work is not completed when the test operation is finished for protection of the air conditioner ask the customer not to operate the air conditioner until the interior finish work is completed If the air conditioner is operated the inside of the indoor units may be polluted by substances generated from the coating and adhensives used for the interior finish work a...
Страница 19: ...the installation manual of the indoor unit After the failure diagnosis finishes press and hold ON OFF button for 4 seconds or longer in the Mainte nance Information screen to erase the malfunction error code history Malfunction diagnosis method When the remote controller displays any item in following table inspect the details in the table If a malfunction error occurs code is displayed Conduct th...
Страница 20: ...ic screen Service Settings menu is displayed 8 2 Select Error History in the Service Settings menu and press Menu Enter button The Error History menu screen is displayed 8 3 Select RC Error History in the Error History menu and press Menu Enter button Malfunction Error codes and Unit No can be confirmed in the RC Error History screen 8 4 In the Malfunction Error History 10 items from the latest ar...
Страница 21: ...ing confirmation screen is displayed 9 6 Select Yes and press Menu Enter button Setting details are determined and Service Settings menu screen returns 9 7 Press Cancel button once The Basic screen returns 9 1 Basic screen Service Settings menu screen 9 2 Return Setting Service Settings Test Operation Maintenance Contact Field Settings Demand Min Setpoints Differential Group Address 1 3 Press Menu...
Страница 22: ...0 2 Press Cancel button twice The Basic screen returns Basic screen 10 1 Cool Set to Cool 28 C Press Menu Enter button Main menu screen Return Setting Main Menu 2 2 Maintenance Information Configuration Current Settings Clock Calender Language Press Menu Enter button Return Maintenance Information Indoor Model 000 Outdoor Model 000 Contact Info 0123 456 7890 Registered details are displayed ...
Страница 23: ... week is set automatically 11 4 Press Menu Enter button Setting confirmation screen is displayed 11 5 Select Yes and press Menu Enter button Setting details are confirmed and Basic screen returns If duration of power outage exceeds 48 hours reset is needed Basic screen Main menu screen 11 1 Return Setting Main Menu Maintenance Information Configuration Current Settings Clock Calendar Language 2 2 ...
Страница 24: ...the Language screen English Deutsch Français Italiano Español Português Nederlands pyccĸий Eλληνικά Тürkçe Polski Press Menu Enter button Setting details are confirmed and Basic screen returns Basic screen Main menu screen 12 1 Return Setting Main Menu Maintenance Information Configuration Current Settings Clock Calendar Language 2 2 Press Menu Enter button 12 2 Return Setting Language English ...
Страница 25: ...y set first change the restrictions to the setting you prefer and only then set the remote controller to sub 13 7 To lock menu button in Basic screen proceed as follows 1 Keep the button pressed 2 Press the 3 other indicated keys simultaneously while keeping the button pressed To unlock menu button in Basic screen follow the same procedure NOTE When pressing a prohibit buttons the will be displaye...
Страница 26: ...Make sure that this controller is set to main factory set first change the restrictions to the setting you prefer and only then set the remote controller to sub NOTE When a function is prohibited the will be displayed next to the function in the Main menu screen Basic screen Main menu screen 14 1 Return Setting Main Menu 1 2 Air Flow Direction Quick Start Ventilation Energy Saving Options Schedule...
Страница 27: ......
Страница 28: ...3P243521 4E EM12A040 1303 AK ...