background image

English 

45

Convenient Functions

Contrast Adjustment

 

„

Operation Method

 

1

Return

Setting

MainMenu

Convenient functions

Setting status list
Clock setting
Language changeover

2/2

Display the main menu screen.

 

(See page 26.)

Press 

 

 buttons to select 

 Convenient functions 

 on the main 

menu screen.
Press Menu/Enter button to display the 
convenient functions settings screen.

 

2

Return

Setting

Convenient functions 

Contrast adjustment

Display changeover

Bring up the convenient functions 

 

settings screen.
Press 

 

 buttons to select 

 Contrast adjustment 

 on the convenient 

functions settings screen.
Press Menu/Enter button to display the 
contrast adjustment settings screen.

 

3

Return

Setting

Adjusts contrast 

Dark 

Light 

Contrast adjustment 

On the contrast adjustment settings 

 

screen press 

 buttons until you reach 

the desired contrast. 
After setting, press Menu/Enter button 
and return to the basic screen. 

01_EN_3P243520-1B.indd   45

01_EN_3P243520-1B.indd   45

5/15/2009   10:21:26 AM

5/15/2009   10:21:26 AM

Содержание BRC1E61

Страница 1: ...ovided before attempting to use the product Keep this manual where it is readily accessible after reading it through If another user operates the product in the future be sure to hand over this manual...

Страница 2: ...Settings Quick Reference of Main Menu Items Main Menu Items 24 Menu Manipulation Manipulating the Main Menu Screen 26 Set temp mode changeover 27 Airflow Direction Setting 28 Quick Cooling Heating On...

Страница 3: ...nd the unit Absolutely keep wet hands away Absolutely keep water and moisture away About Remote Controller WARNING Do not install the remote controller by yourself Improper installation may result in...

Страница 4: ...t exposure to cool or warm air from the air conditioner or to air that is too cool or too warm can be harmful to your physical condition and health Do not place objects including rods your fingers etc...

Страница 5: ...lectric shocks or fire A high surge current from lightning or other sources may cause damage to the air conditioner When the air conditioner is malfunctioning giving off a burning odour etc turn off p...

Страница 6: ...hocks or fire Do not use the air conditioner for purposes other than those for which it is intended Do not use the air conditioner for cooling precision instruments food plants animals or works of art...

Страница 7: ...the resin parts of the indoor unit or cause water leakage Moreover malfunctions smoke generation or ignition may result if the electric parts or motor in the indoor unit is wet with detergent Do not...

Страница 8: ...English 7 01_EN_3P243520 1B indd 7 01_EN_3P243520 1B indd 7 5 15 2009 10 21 01 AM 5 15 2009 10 21 01 AM...

Страница 9: ...o not pull or twist the remote controller cord Otherwise the remote controller may error Do not press the buttons on the remote controller with objects with sharp ends Otherwise the remote controller...

Страница 10: ...press the part with the symbol Used to highlight the next items on the right hand side Each screen is scrolled in the right hand direction Home leave settings are enabled with this button kept presse...

Страница 11: ...alized control 9 display 2 Automatic operation mode Detailed display The airflow direction clock and detailed selection items appear on the detailed display screen in addition to the items appearing o...

Страница 12: ...provided with the corresponding function Error Press Menu Button Warning Press Menu Button Displayed if the error or warning is detected see page 53 Quick Cool Heat SkyAir only Displayed if the quick...

Страница 13: ...not provided with a function to set airflow directions Clock 24 hours real time clock 14 Displayed if the clock is set see page 48 If the clock is not set will be displayed Detailed selection 15 Displ...

Страница 14: ...English 13 01_EN_3P243520 1B indd 13 01_EN_3P243520 1B indd 13 5 15 2009 10 21 03 AM 5 15 2009 10 21 03 AM...

Страница 15: ...at least six hours before starting the operation of the system Do not turn OFF the system in season in order to ensure the smooth starting of the system Operation Method 1 Set temperature 28 C Cool Re...

Страница 16: ...speed adjustment levels Low High may be available depending on the type of indoor unit The system may be in automatic fan speed control for mechanical protection purposes The system may be in automat...

Страница 17: ...rt operating the system in advance by utilizing the timer Perform the following operation of the system in order to prevent the degradation of the heating capability or cold winds from blowing out Def...

Страница 18: ...ertain level If the hot air stays around the ceiling and your feet feel cold the use of a circulator is recommended For details consult your Daikin dealer Program Dry Operation Preparation For mechani...

Страница 19: ...cannot be changed unless the system is provided with a function to allow airflow direction changes 4 The Operation lamp will be turned OFF and the system will stop operating when On Off button is pre...

Страница 20: ...when the occupants are out Note This function will switch on heating if the installation is switched off Operation Method The home leave can not be enabled when a centralized control is connected 1 Se...

Страница 21: ...eat exchanger without the system between seasons 2 To change the ventilation mode setting make necessary settings from the main menu see page 33 Ventilation mode Automatic Heat exchange and Bypass 3 T...

Страница 22: ...n the cooling heating selection remote controller all the remote controllers will display Changeover under control In this case no cooling heating selection eligibility can be set in the remote contro...

Страница 23: ...the cooling heating selection eligibility is set The display Auto will appear for the heating cooling simultaneous operation system only 1 The remote controller with the selection eligibility Set to C...

Страница 24: ...r units Set the cooling heating auto fan selection eligibility in one of the remote controllers BS unit The BS unit is used for cooling or heating mode selection Key Lock Operation Method Make setting...

Страница 25: ...gh 32 Ventilation mode Used to set Automatic Heat exchange and Bypass 33 Timer setting Schedule timer Operation start time and stop time can be set according to the day of the week Either one of the f...

Страница 26: ...r a period not exceeding 48 hours the clock will continue working with the built in backup power supply The clock needs settings again if the power failure period exceeds 48 hours 48 Language changeov...

Страница 27: ...en The main menu screen will appear Instructions for manipulating the buttons will appear 3 Selecting items from the main menu 1 Press buttons to select the desired item to be set 2 Press Menu Enter b...

Страница 28: ...en Pressing Menu Enter button takes you back to the basic screen and the set temperature is displayed in max C min C Limit Operation To return to the normal set temperature screen use Set temp mode ch...

Страница 29: ...with no airflow direction adjustment Airflow Direction will not be displayed on the main menu screen 2 Return Setting Airflow Direction Swing Airflow direction setting up down Return Setting Swing Air...

Страница 30: ...ing setting only all positions will be displayed 4 Return Setting Position 2 Airflow Direction Up down direction Return Setting Airflow Direction Position 2 Left right direction When you select one of...

Страница 31: ...ation conditions shown below airflow direction is controlled automatically Actual operation may thus be different than what is displayed on the remote controller Operation condition Room temperature i...

Страница 32: ...appear on the basic screen Quick Cooling Heating is now on Quick Cooling Heating Off Operation Method 2 Return Setting MainMenu Set temp mode changeover Airflow Direction Quick Cool Heat On Off Venti...

Страница 33: ...Setting MainMenu Set temp mode changeover Airflow Direction Quick Cool Heat On Off Ventilation Timer setting Service Contact Model Info 1 2 Return Setting Ventilation Ventilation rate Ventilation mod...

Страница 34: ...ate Changing ventilation mode Operation Method 1 Return Setting Ventilation Ventilation rate Ventilation mode 2 2 Display the ventilation settings screen See page 32 Press buttons to select Ventilatio...

Страница 35: ...de Outside air is supplied to inside the room without undergoing heat exchange Timer Settings Display method for timer settings screen Operation Method 1 Return Setting MainMenu Set temp mode changeov...

Страница 36: ...is not carried out Do you want to set Schedule timer Yes No Return Setting Clock setting Year 2008 Month 01 Day 01 Tuesday 00 00 Before setting the schedule timer the clock must be set If the clock h...

Страница 37: ...elect the day to be set on the condition setting screen Input the program for the selected day next The schedule timer can accept a maximum of 5 operations per day 3 Return Setting Monday Schedule tim...

Страница 38: ...2 1 3 To make an operation change at set temperature press buttons to move the highlighted item and press buttons to set the operation to 22 C Return Setting Monday Schedule timer Time Operation 06 00...

Страница 39: ...ule timer Time Operation 06 00 28 C 12 30 20 C 26 C Press buttons to select the desired temperature to be changed Return Setting Monday Schedule timer Time Operation 06 00 28 C 12 30 20 C 28 C Return...

Страница 40: ...ector button so that the settings will be copied as they are Example The contents for Monday are copied by pressing the operation mode selector button after selecting Tuesday 8 Return Setting Monday S...

Страница 41: ...e holiday settings Pressing buttons switches the setting between set and release Multiple days can be selected as holidays Note To able the schedule timer for the day selected as a holiday the holiday...

Страница 42: ...reen Press Menu Enter button to display the enable disable settings screen 2 Return Setting Enable Disable setting Schedule timer Disable Press buttons to select Enable or Disable on the enable disabl...

Страница 43: ...Return Setting Each time after pressing the operation button automatically stops after 60 minutes Off reminder Timer Use buttons to set the time from operation start until the unit automatically stops...

Страница 44: ...urn Setting Enable Disable setting Off reminder Timer Disable Press buttons to select Enable or Disable on the enable disable settings screen Press Menu Enter button after selecting the item Then the...

Страница 45: ...Contact address 0123 456 7890 The phone number for the contact address will appear at the top of the screen If you have not yet registered your product it will not appear The model information of the...

Страница 46: ...functions Contrast adjustment Display changeover Bring up the convenient functions settings screen Press buttons to select Contrast adjustment on the convenient functions settings screen Press Menu E...

Страница 47: ...isplay Standard Desired disp select None Press buttons to select Display on the convenient functions settings screen Press Menu Enter button to display the display settings screen 3 Return Setting Dis...

Страница 48: ...may not display these items even if they are selected Be sure to read the following notes regarding display of room temperature and outdoor temperature Room temperature An estimate of the temperature...

Страница 49: ...buttons to go to the next item Pressing Cancel button takes you back to the main menu screen Airflow direction Off reminder timer Ventilation rate Quick Cool Heat Ventilation mode Display changeover S...

Страница 50: ...ding down the button causes the number to change continuously Days of the week change automatically 5 Return Setting Clock setting Year 2008 Month 10 Day 07 Tuesday 12 00 Select Hour with buttons Inpu...

Страница 51: ...status list Clock setting Language changeover 2 2 Display the main menu screen See page 26 Press buttons to select Language changeover on the main menu screen and press the Menu Enter button 2 Return...

Страница 52: ...Reset the filter sign when the filter or element is washed cleaned or replaced Press Menu Enter button The main menu screen will appear 3 Return Setting MainMenu Filter Sign Reset Set temp mode chang...

Страница 53: ...rty If the dirt on the surface cannot be removed soak the cloth in neutral detergent diluted with water squeeze the cloth tightly and clean the surface Wipe the surface with a dry cloth then Note Do n...

Страница 54: ...or Press Menu Button If an error occurs either one of the following items will blink in the basic screen Error Press Menu Button The operation indicator will blink Warning Press Menu Button The operat...

Страница 55: ...ditions As precise as possible Your address name and telephone number Relocation The relocation of the remote controller requires special technology Consult your Daikin dealer Actual expenses required...

Страница 56: ...3P243520 1B EM08A100A 0906 HT 00_CV_3P243520 1B indd 4 00_CV_3P243520 1B indd 4 5 15 2009 10 15 44 AM 5 15 2009 10 15 44 AM...

Отзывы: