Daikin BRC1D517 Скачать руководство пользователя страница 16

 

Operation manual

13

BRC1D517

Remote controller

4PW15196-1A

3

I WANT TO DELETE ONE OR MORE 
PROGRAMMED ACTIONS

Make sure you are not in program mode (

 not

blinking); if required, press 

 to quit program

mode.

Browse to the programmed actions using the 
button, select the day you want to edit. 

Press the 

 button for 5 seconds; program mode is

enabled, the 

 icon and selected action are blinking. 

Select the "last action" you want to keep using the

 button. All higher actions will be deleted. 

Confirm the deletion by pressing the 

 button for 5

seconds, 

OR 

confirm the deletion for the current and the next day
too by pressing the 

 and 

 buttons

simultaneously for 5 seconds. 

4

I WANT TO DELETE ALL PROGRAMMED 
ACTIONS AT ONCE

Quit programming or browsing.

Press the 

 and 

 buttons simultaneously for 5

seconds; the 

 icon will invert and disappear to

confirm deletion.

7. Maintenance

The remote controller does not need maintenance.

Remove dirt with a soft damp cloth.

8. Troubleshooting

The guidelines below might help to solve your
problem. If you cannot remedy the problem, consult
your installer.

No readings on the remote controller (display 
blank)

Check if the mains power is still applied to your
installation.

Only 

 is displayed

This indicates that the installation has just been
powered, please wait until 

 disappears.

The schedule timer does work but the 
programmed actions are executed at the wrong 
time (e.g. 1 hour too late or too early)

Check if the clock and the day of the week are set
correctly, correct if necessary (refer to 

"CLOCK

SETTING FUNCTION" on page 4

).

I cannot enable the schedule timer (the 

 icon 

blinks for 2 seconds and disappears)

The schedule timer has not been programmed yet.
First program the schedule timer (refer to

"Programming the schedule timer" on page 10

).

I cannot enable the schedule timer (the 

 

icon is displayed)

The schedule timer can not be enabled when a
centralised control is connected.

Limit operation cannot be selected 

Limit operation is not available for cooling only
installations.

NOTE

In the case above, if for example the last
action was 3,  the programmed actions 4
and 5 will also be deleted (if they were
present).

NOTE

Only use clear tapid water to moisten the
cloth.

Содержание BRC1D517

Страница 1: ...Remote controller BRC1D517 OPERATION MANUAL Switching from limit operation mode to automatic operation mode heat pump models only is not supported for Sky Air indoor models...

Страница 2: ...1 1 1 2 9 3 25 22 11 10 37 35 27 26 12 14 17 34 24 5 20 21 18 16 13 15 19 32 31 30 29 28 4 36 33 8 23 7 6...

Страница 3: ...2 2 Start 5s 5s 5s 5s 5s End...

Страница 4: ...ume adjustment air flow direction adjustment 2 CLOCK FUNCTION The clock functions are 24 hours real time clock day of the week indicator 3 SCHEDULE TIMER FUNCTION The schedule timer functions are a ma...

Страница 5: ...ventilation icon appears when the ventilation is adjusted with the ventilation amount button only Simultaneously the ventilation amount is indicated by the fan speed icon see 22 6 AIR CLEANING ICON Th...

Страница 6: ...s only 20 AIR FLOW DIRECTION ICON This icon indicates the air flow direction only for installations with motorised air flow flaps 21 NOT AVAILABLE is displayed whenever a non installed option is addre...

Страница 7: ...After initial installation the user can set the clock and day of the week The controller is equipped with a schedule timer that enables the user to operate the installation automatically setting the c...

Страница 8: ...reached and is displayed This prevents cold air from leaving the indoor unit Defrost heat pump types only In heating operation freezing of the outdoor heat exchanger may occur If so the heating capac...

Страница 9: ...TION User adjustable parameters Setpoint temperature use the buttons Fan speed use the button Air flow direction adjust use the button Ventilation mode use the button Ventilation amount use the button...

Страница 10: ...the schedule timer Use the button to enable or disable the schedule timer To set up the SCHEDULE TIMER refer to chapter 6 Programming the schedule timer on page 10 KEEP IN MIND THAT THE BUTTON MUST BE...

Страница 11: ...at will the schedule timer NOT do The schedule timer will not control fan speed control air flow direction control ventilation mode control ventilation amount change the operation mode for a scheduled...

Страница 12: ...day not blinking you have now quit browsing How do I interpret the programmed actions To be able to understand the behaviour of your installation when the schedule timer is enabled it is important to...

Страница 13: ...amming steps are limited to a minimum Below are some tips and tricks to ensure successful programming of the schedule timer familiarise yourself with the icons and the buttons you will need them when...

Страница 14: ...in limit operation the selected temperature will blink Enter the time when the action must start using the buttons min step 10 minutes NOTE When changing day during programming you will have to confir...

Страница 15: ...d if no actions were copied from Monday to Tuesday 2 I WANT TO EDIT PROGRAMMED ACTIONS Editing programmed actions is easy Make sure you are not in program mode not blinking if required press the butto...

Страница 16: ...lp to solve your problem If you cannot remedy the problem consult your installer No readings on the remote controller display blank Check if the mains power is still applied to your installation Only...

Страница 17: ...NOTES...

Страница 18: ......

Страница 19: ......

Страница 20: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN15196 1A...

Отзывы: