Daikin BRC1D517 Скачать руководство пользователя страница 12

 

Operation manual

9

BRC1D517

Remote controller

4PW15196-1A

The 

 button is used to exit browsing at once

(without having to scroll through all programmed
actions).

Press the 

 button to enter the browse mode, the

 icon appears, 

 will blink.

Check the 

 icon. If at least 1 action is

programmed for Monday,   will appear. 

The clock indicates the time when the programmed
action is scheduled, either 

 or 

 and

 is being displayed.

If   does not appear, it indicates that there are no
programmed actions for Monday.

Press the 

 button again to go to the next day of

the week. 

 will blink, this indicates that the

programmed actions for Tuesday are being browsed.

The process described above is now restarted.

If at least 1 action is programmed for Tuesday,   will
appear. The clock indicates the time when the
programmed action will be enabled, either 

,

 or 

 and 

 is being displayed.

If   does not appear, it indicates that there are no
programmed actions for Tuesday.

Press the 

 button to display the next programmed

action. If a second action is programmed for Tuesday,

 will still be blinking and 

 will appear. 

Assuming that 5 actions were programmed for
Tuesday, a total of 5 presses will be required to
display all programmed actions.

Continue pressing the 

 button until the day of the

week indicator displays the current day (not blinking),
you have now quit browsing.

How do I interpret the programmed 
actions

To  be able to understand the behaviour of your
installation when the schedule timer is enabled, it is
important to look at all programmed actions for the
current day and maybe the last programmed action of
yesterday.

If the first programmed action for today is not active
yet, the current status of your installation depends,
most probably but not necessarily, on the last
programmed action from yesterday. Read the
important note below.

If the first programmed action for today is already
active, the current status of your installation depends,
most probably but not necessarily, on the parameters
programmed in the first programmed action for today.
Read the important note below.

Conclusion: Although 

 is displayed, somebody

might have altered the settings. The next
programmed action will overrule the altered settings
and all settings return as programmed.

NOTE

Browsing always starts on Monday and
ends on Sunday.

NOTE

The temperatures mentioned above are
for clarifying purposes only, temperature
values on your controller may vary.

NOTE

The number of times that the 

 button

will have to be pressed to quit browsing
depends on the number of programmed
actions in the schedule timer. 

NOTE

To keep the operation of your installation
simple, the schedule timer settings can
easily be overruled by altering the current
setting ("last command" overrules
previous command until next scheduled
command).

Содержание BRC1D517

Страница 1: ...Remote controller BRC1D517 OPERATION MANUAL Switching from limit operation mode to automatic operation mode heat pump models only is not supported for Sky Air indoor models...

Страница 2: ...1 1 1 2 9 3 25 22 11 10 37 35 27 26 12 14 17 34 24 5 20 21 18 16 13 15 19 32 31 30 29 28 4 36 33 8 23 7 6...

Страница 3: ...2 2 Start 5s 5s 5s 5s 5s End...

Страница 4: ...ume adjustment air flow direction adjustment 2 CLOCK FUNCTION The clock functions are 24 hours real time clock day of the week indicator 3 SCHEDULE TIMER FUNCTION The schedule timer functions are a ma...

Страница 5: ...ventilation icon appears when the ventilation is adjusted with the ventilation amount button only Simultaneously the ventilation amount is indicated by the fan speed icon see 22 6 AIR CLEANING ICON Th...

Страница 6: ...s only 20 AIR FLOW DIRECTION ICON This icon indicates the air flow direction only for installations with motorised air flow flaps 21 NOT AVAILABLE is displayed whenever a non installed option is addre...

Страница 7: ...After initial installation the user can set the clock and day of the week The controller is equipped with a schedule timer that enables the user to operate the installation automatically setting the c...

Страница 8: ...reached and is displayed This prevents cold air from leaving the indoor unit Defrost heat pump types only In heating operation freezing of the outdoor heat exchanger may occur If so the heating capac...

Страница 9: ...TION User adjustable parameters Setpoint temperature use the buttons Fan speed use the button Air flow direction adjust use the button Ventilation mode use the button Ventilation amount use the button...

Страница 10: ...the schedule timer Use the button to enable or disable the schedule timer To set up the SCHEDULE TIMER refer to chapter 6 Programming the schedule timer on page 10 KEEP IN MIND THAT THE BUTTON MUST BE...

Страница 11: ...at will the schedule timer NOT do The schedule timer will not control fan speed control air flow direction control ventilation mode control ventilation amount change the operation mode for a scheduled...

Страница 12: ...day not blinking you have now quit browsing How do I interpret the programmed actions To be able to understand the behaviour of your installation when the schedule timer is enabled it is important to...

Страница 13: ...amming steps are limited to a minimum Below are some tips and tricks to ensure successful programming of the schedule timer familiarise yourself with the icons and the buttons you will need them when...

Страница 14: ...in limit operation the selected temperature will blink Enter the time when the action must start using the buttons min step 10 minutes NOTE When changing day during programming you will have to confir...

Страница 15: ...d if no actions were copied from Monday to Tuesday 2 I WANT TO EDIT PROGRAMMED ACTIONS Editing programmed actions is easy Make sure you are not in program mode not blinking if required press the butto...

Страница 16: ...lp to solve your problem If you cannot remedy the problem consult your installer No readings on the remote controller display blank Check if the mains power is still applied to your installation Only...

Страница 17: ...NOTES...

Страница 18: ......

Страница 19: ......

Страница 20: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN15196 1A...

Отзывы: